Preferred Language
Articles
/
fReFi5IBVTCNdQwCq7S5
Determination and Isolation of Valuable Bioactive Compound (lupeol) from Portulacaria afra Jacq.
...Show More Authors

Portulacaria afra is a small succulent tree, previously belonging to the Portulacaceae family, but with further studies, the plant transferred to the Didieracea family. P. afra was used as an ornamental, vegetable, and ethnomedicinal plant. Uses of the plant by rural South Africans to treat chronic skin conditions and rashes, alleviate exhaustion, and aid in treating TB and diarrhea have been documented in folklore. According to pharmaceutical research, plant extracts off er a wide range of remedial outcomes, such as antidiabetic, antifungal, antibacterial, anticancer, antioxidant, and anti-infl ammatory. The study aims to determine some bioactive constituents responsible for pharmacological activities and traditional usefulness. Thinlayer chromatography (TLC) is used for detecting lupeol by specifi c reagents; a p-anisaldehyde sulfuric acid reagent and 10% methanolic sulfuric acid. And high-performance liquid chromatography was used to detect pentacyclic triterpenoids (lupeol) in the n-hexane. The lupeol was isolated by preparative layer chromatography (PLC). Testing the effi cacy of the separation method, the isolated compounds have been identifi ed and characterized by diff erent chromatographic and chemical analyses (TLC, ATR-FTIR, LC-CMS-APCI+, and 1H-NMR).

Scopus Crossref
View Publication
Publication Date
Fri Jun 30 2023
Journal Name
Malaysian Journal Of Science
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR
...Show More Authors

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma

... Show More
View Publication
Scopus Crossref
Publication Date
Sat May 04 2024
Journal Name
Chemchemtech
HPLC METHOD FOR THE DETERMINATION OF SOME ANTIBIOTIC RESIDUES IN DIFFERENT HOSPITALS WASTEWATER IN BAGHDAD CITY, IRAQ
...Show More Authors

Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, AlKindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 co

... Show More
Scopus
Publication Date
Fri Apr 30 2021
Journal Name
Iraqi Journal Of Science
Determination of the Annual Optimal Reliable Frequency for Different Transmitter/Receiver Stations Distributed over the Iraqi Territory
...Show More Authors

This paper aimed to determine the Optimal Reliable Frequency (ORF) that can maintain certain connection link between different transmitter/receiver stations laid over the Iraqi territory. Three different transmitting sites were chosen as tested stations located in the northern, central, and southern regions of Iraq. These sites are Mosul, Baghdad, and Basra, respectively. In this study, the years 2009 and 2014, which represent the minimum and maximum years of solar cycle 24, were chosen to examine the effect of low and high solar activity on the determined ORF. The datasets of the Best Usable Frequency (BUF) were calculated using the ASAPS international communication model. An analytical study was made on the generated BUF parameter data

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Copper(II) using 2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole](MBBAI)
...Show More Authors

            Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Corrosion Parameters for a Cathodic Reaction Complicated by IR Drop Effect in a Flow System
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector
...Show More Authors

In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Cu(II) by Complex with Ethyl Cyano(2-Methyl Carboxylate Phenyl Azo Acetate) (ECA)
...Show More Authors

  A new simple and sensitive spectrophotometric method for the determination of trace amount of Cu(II) in the ethanol solution have been developed. The method is based on the complexation of Cu(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in basic medium of sodium hydroxide givining maximum absorbance at (λmax = 521 nm). Beer's law is obeyed over the concentration range (5-50) (μg / ml) with molar absorptivity of (3.1773 × 102 L mol-1 cm-1) and correlation coefficient (0.9989). The optimum conditions for the determination of Cu(II)-complex and have been studied and applied to determine Cu(II) in synthetic water sample using simple and standard addition methods.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
New Fluorometric Method for the Determination of Ketotifen Fumarate Using Continuous Flow Injection Analysis via ISNAG-fluorimeter
...Show More Authors

        A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa

... Show More
View Publication Preview PDF