The study of the relationship between the coordinates of the sun and the moon with the crescent visibility factors has not been previously treated in a detailed and accurate way in research and previous studies, despite its religious importance. Accordingly, this paper aims to study the relationship between the crescent visibility factors (age, lag time, elongation (ARCL), arc of vision or relative altitude (ARCV), relative azimuth (DAZ), and crescent width (W), with coordinates of the sun and the moon), and how it varies during the day of the crescent's observation. In this paper, Matlab programs were designed to calculate the ecliptic sun and moon coordinates (λ, β) and in the presence of all perturbation impacts (planets), then convert these coordinates to the equatorial (α, δ) and horizontal coordinates (A, a). The results were compared with other programs in this field and references such as the ephemeris, accurate times, and astronomical programs. The variation of the sun and moon coordinates (ecliptic, equatorial, and horizontal) was studied with time, and the relationship of those coordinates was explained with visibility crescent factors during the day of the crescent's observation. Finally, the relationship of those factors with each other was studied. The results indicated that there was a relationship between the sun and the moon coordinates with some factors of crescent visibility in critical and standard observations, where the critical observations of the moon (age, lag time, elongation) were increased when the sun and the moon coordinates approach from two equinox points (spring and autumn), while the other factors, such as the relative azimuth and relative altitude, were independent on the change of the coordinates through the year. Also, a relationship was found between the visibility factors with each other, this led to a direct relationship between increasing the elongation with the crescent width. The values of the relative altitude were also increased with the increase in the lag time. Lastly, there was a direct relationship between the increase in the relative azimuth and the relative altitude.
BACKGROUND: The degree of the development of coronary collaterals is long considered an alternate – that is, a collateral – source of blood supply to an area of the myocardium threatened with vascular ischemia or insufficiency. Hence, the coronary collaterals are beneficial but can also promote harmful (adverse) effects. For instance, the coronary steal effect during the myocardial hyperemia phase and that of restenosis following coronary angioplasty. OBJECTIVES: Our study explores the contribution of coronary collaterals – if any exist – while considering other potential predictors, including demographics and medical history, toward the left ventricular (LV) dysfunction measured through the LV ejection fraction (LVEF). METH
... Show MoreA thin CdS Films have been evaporated by thermal evaporation technique with different thicknesses (500, 1000, 1500 and 2000Å) and different duration times of annealing (60, 120 180 minutes) under 573 K annealing temperature, the vacuum was about 8 × 10-5 mbar and substrate temperature was 423 K. The structural properties of the films have been studied by X- ray diffraction technique (XRD). The crystal growth became stronger and more oriented as the film thickness (T) and duration time of annealing ( Ta) increases.
Copper oxide thin films were deposited on glass substrate using Successive Ionic Layer Adsorption and Reaction (SILAR) method at room temperature. The thickness of the thin films was around 0.43?m.Copper oxide thin films were annealed in air at (200, 300 and 400°C for 45min.The film structure properties were characterized by x-ray diffraction (XRD). XRD patterns indicated the presence of polycrystalline CuO. The average grain size is calculated from the X-rays pattern, it is found that the grain size increased with increasing annealing temperature. Optical transmitter microscope (OTM) and atomic force microscope (AFM) was also used. Direct band gap values of 2.2 eV for an annealed sample and (2, 1.5, 1.4) eV at 200, 300,400oC respect
... Show MoreTourism is one of the most important sources of income of economic key countries in the world so are imports of tourism for some countries a source of income is not significant of the total revenues of States. Making those countries, and those countries a destination for visitors, and here should be interest in the Wealth and cultural heritage that distinguishes Islamic countries in general, and Iraq in particular, must be placed specialist studies in all areas for the development of this area of tourism, especially religious tourism to achieve a desired and desired of such research.It is the most important ways to develop tourism in general and religious tourism is of particular publications, advertising, and is important for us in this
... Show MoreObjective: The aim of this study was to evaluate the effect of pumice, burning investment material
and black sand on the surface roughness of heat cure acrylic resin.
Methodology: Sixty specimens were prepared from pink heat cure acrylic resin, the specimens
where grouped into; 20 specimens which polished with pumice and water (control group); 20
specimens which polished with investment material (after burning it) and water; and 20 specimens
which polished with black sand and water. The average surface roughness of specimens after
polishing procedure had been determined by profilometer (surface roughness tester).
Results: Through the application of ANOVA and LSD tests, the result of this study showed that there
wa
Three types of medical commercial creams Silvazine, Cinolon Tar and Hydroquinon Domina were incorporated in this study. The medical creams were taken directly and placed uniformly on the glass slide. Each type of pharmaceutical was weighed at 1 mg and dispersed on an area of 1x1 cm. This process ensures same thickness for all samples. The creams were analyzed by using double-beam UV/visible spectrophotometer Metertech SP8001. The absorption spectrum for each of samples was measured against wavelength range of 300–700 nm.