Computers have been used for numerous applications involving the automatic or semiautomatic recognition of patterns in image. Advanced manufacturing system requires automated inspection and test method to increase production and yield best quality of product. Methods are available today is machine vision. Machine vision systems are widely used today in the manufacturing industry for inspection and sorting application. The objective of this paper is to apply machine vision technology for measuring geometric dimension of an automotive part. Vision system usually requires reprogramming or parameterization of software when it has to be configured for a part or product. A web camera used to capture an image of an automotive part that has been chosen. In the machine vision, Matlab software is used to develop an algorithm to measure a geometric dimension of the part. The measurement system has been calibrated using gauge block. This work considers the factor influencing parameters on accuracy and precision of calibration as the pixels were used to perform the unit of measurement. This measurement has been performed by the conversion through the equation of the image processing. Formulation of the calibration is important from unit in pixel to mm taking into account the perfective effect of the camera view. Finally the measurement system has been tested for accuracy and precision.
The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photom
... Show MoreVarious Hall Effects have been successfully observed in samples of n-type indium antimonide with values for conductivity, energy gap, Hall mobility and Hall coefficient all agreeing with theory. A particular interest in developing a method for obtaining accurate values of carrier concentrations in semiconductor samples has been fulfilled with an experimental result of (1.6×1016 cm-3 ±10.7%) giving a percentage difference of (6.7%) to a quoted value of (1.5×1016cm-3) at (77K) using an (80mW C.W. CO2) laser beam at (10.6μm) to illuminate a similar sample of n-type indium antimonide, an "Optical" Hall effect has been observed. Although some doubt has been raised as to the validity of effect i.e. "thermal" rather than "Optical", values o
... Show MoreAbstract:
Inclusive education has experienced a number of positive educational trends and developments in many different countries, typically by recognising that all students, including those who have special educational needs (SEN), have a right to education. Inclusion of children with SEN in mainstream schools, alongside their peers, has become a major concern for interested educators, professionals and parents in many countries around the world. The reasons for this trend are due to a number of factors such as the increasing attention to the role of education in achieving social justice for pupils with SEN; the right of individuals with SEN to be educated along with their typically developing peers in mainstr
... Show MoreA simple, rapid, accurate and sensitive spectrophotometric method for the determination of thiaminehydrochloride has been developed. The method is based on the formation of the Schiff’s base between the primary amino group present in thiamine hydrochloride and aldehyde group present in the vanillin reagent to produce a yellow colored complex having maximum absorption at 390 nm. Beer’s law has obeaid over the concentration range of 2-28µg/mL, with molar absorptivity of 0.96x104L/mol.cm. The average recovery which is a measure of accuracy is 100±1.3% and the relative standard deviation (RSD) is less than1.5 .The present method is considered to be
... Show MoreReview of multidrug sensitivity and resistance in enterococcus
Impact of buildings in Iraq and other countries on the environment is obvious; this problem began to take scientific and humanitarian dimensions in order to reduce and eliminate this problem. This impact can be seen through the energy, water and raw materials consumed for the establishment, operation and maintenance of these buildings, as well as the emissions of hazardous gases and generations of solid wastes.
This work was conducted to assess the current maintenance managerial practice for the governmental buildings to stand on the main obstacle and extrapolation of measures by means of interviews with experts to determine the effective factors and closed questionnaire to state the features and the need for new
... Show More
