Objectives: To explore the correlation between maternal and cord blood prolactin, the correlation between cord prolactin and birth weight, and to compare cord blood prolactin in new-borns of women with normal pregnancy and women with pregnancy complications namely; gestational hypertension, gestational diabetes and preterm labour.Methods: This study was performed from September to December 2018. Thirty-two women, delivered at Baghdad teaching hospital, and their newborns (32) were included. Maternal blood (5 ml) was taken before labour and cord blood (5 ml) was collected after placenta expulsion. Maternal and cord blood prolactin were analysed using fluorescence immunoassay. Results: Cord blood prolactin was higher in babies born to hypertensive women (405.28±77.52 ng/ml) than normal pregnancy women (244.80±60.80 ng/ml), P=0.000. Also, cord prolactin in gestational hypertension group was significantly higher than diabetic (P=0.006) and preterm labour (P=0.000) groups. No significant difference was noticed in cord blood prolactin in newborns of diabetic and normal pregnancy women (299.28±37.01, 244.80±60.80 ng/ml respectively, P=0.053). Preterm babies had lower cord prolactin (204.57±22.90 ng/ml) than normal pregnancy babies (244.80±60.80 ng/ml), however the difference was non-significant, P=0.118. Positive correlation was found between cord and maternal prolactin (P=0.000) and between cord prolactin and birth weight (P=0.018). Conclusion: Cord blood prolactin is high in newborns of hypertensive women, low in preterm neonates. Diabetes has no effect on cord prolactin level. doi: https://doi.org/10.12669/pjms.35.4.558 How to cite this:Alawad ZM, Al-Omary HL. Maternal and cord blood prolactin level and pregnancy complications. Pak J Med Sci. 2019;35(4):1122-1127. doi: https://doi.org/10.12669/pjms.35.4.558 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
In the drilling and production operations, the effectiveness of cementing jobs is crucial for efficient progress. The compressive strength of oil well cement is a key characteristic that reflects its ability to withstand forceful conditions over time. This study evaluates and improves the compressive strength and thickening time of Iraqi oil well cement class G from Babylon cement factory using two types of additives (Nano Alumina and Synthetic Fiber) to comply with the American Petroleum Institute (API) specifications. The additives were used in different proportions, and a set of samples was prepared under different conditions. Compressive strength and thickening time measurements were taken under different conditions. The amoun
... Show MoreAims: This study was conducted to assess the effect of the addition of yttrium oxide (Y2O3) nanoparticles on the tensile bond strength, tear strength, shore A hardness, and surface roughness of soft-denture lining material. Materials and Methods: Y2O3 NPs with 1.5 and 2 wt.% were added into acrylic-based heat-cured soft-denture liner. A total of 120 specimens were prepared and divided into four groups according to the test to be performed (tensile bond strength, tear strength, surface hardness, and surface roughness). Results: There was a highly significant increase in tensile bond strength between the soft liner and the acrylic denture base, tear strength, and hardness at both concentrations as compared to the control group, whereas ther
... Show MoreObjective: Evaluate the effects of different storage periods on flexural strength (FS) and degree of conversion (DC) of Bis-Acryl composite and Urethane dimethacrylate provisional restorative materials. Material and Methods: A total of 60 specimens were prepared from four temporary crown materials commercially available and assigned to four tested groups (n = 15 for each group): Prevision Temp, B&E CROWN, Primma Art, and Charm Temp groups. The specimens were stored in artificial saliva, and the FS was tested after 24 h, 7 d, and 14 d. A standard three-point bending test was conducted using a universal testing machine. Additionally, the DC was determined using a Fourier transform infrared spectroscopy (FTIR) device. The data were analyzed st
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show More