The present work aimed to examine the nature and degree of the cross-correlations among three different ionospheric indices: these are Optimum Working Frequency (OWF), Highest Probable Frequency (HPF), and Best Usable Frequency (BUF). VOCAP and ASASPS models were adopted to determine the datasets of the selected ionospheric indices. The determination was made for different transceiver stations that provide certain HF connection links during the minimum and maximum years of solar cycle 24, 2009 and 2014, respectively. Matlab program was implemented to produce the geodesic parameters for the selected transceiver stations. The determination was made for different path lengths (500, 1000, 1500, and 2000) Km and bearings (0o, 45o, 90o ........ 315o). Different correlation methods were used to examine the best determination coefficient values between the tested parameters. A third-order polynomial equation was set as the best correlation method that gave a better description for the correlation among the tested parameters. The proposed mathematical correlation equations were used to predict the seasonal values of the (HPF, OWF and BUF) parameters. The proposed equations were verified by comparing their values with the observed datasets during the study years. Also, the predicted values were tested using different statistical methods, which gave good results for all tested cases. يهدف العمل الحالي إلى دراسة طبيعة ودرجة الترابط بين ثلاثة مؤشرات آيونوسفيرية مختلفة وهي (HPF,OWF and BUF), تم استخدام نماذج VOCAP و ASASPS لحساب قيم البيانات للمؤشرات الآيونوسفيرية المختارة. اجريت الحسابات لمحطات الإرسال / الاستقبال المختلفة التي توفر روابط اتصال عالية التردد خلال سنوات الصغرى والعظمى للدورة الشمسية 24 (2009 و 2014) على التوالي. تم تنفيذ برنامج Matlab لايجاد قيم المعلمات الجيوديسية لمحطات الإرسال / الاستلام لأطوال مسافات مختلفة (500، 1000، 1500 و 2000) كم واتجاهات مختلفة(0o, 45o, 90o ........ 315o). تم تطبيق طرق ارتباطية مختلفة لاختبار افضلها بين المعاملات المختبرة . تم اقتراح معادلات رياضية متعددة الحدود (الدرجة الثالثة) كأفضل طريقة تصف القيم الارتباطية بين المعاملات المحددة لغرض الدراسة. تمكنت المعادلات المقترحة من التنبؤ بالقيم الموسمية للمؤشرات ((HPF و(OWF) و (BUF).و تم التحقق منها من خلال مقارنتها مع قيم المعلمات المرصودة خلال سنوات الدراسة . كما تم اختبار القيم المتوقعة باستخدام طرق إحصائية مختلفة والتي قدمت نتائج جيدة لجميع الحالات المختبرة
The research aims to identify the degree of crystallized intelligence among Intermediate School Female Students , and the research sample reached (200) students. The two researchers used the crystallized intelligence test tool prepared by Dr. (Morsi, 2001), The use of words and their meanings (linguistic outcome), abstract thinking, the acquisition of general information and experiences in daily life, the use of numbers and their sequence, mathematical thinking). To the next Results: the weakness of crystallized intelligence among Intermediate School Female Students with a statistical significance of (0.05) And done analyzed in the light of the results and recommendations.
The CIGS/CdS p-n junction thin films were fabricated and deposited at room temperature with rate of deposition 5, and 6 nm secG1 , on ITO glass substrates with 1mm thickness by thermal evaporation technique at high vacuum pressure 2×10G5 mbar, with area of 1 cm2 and Aluminum electrode as back contact. The thickness of absorber layer (CIGS) was 1 µm while the thickness of the window layer CdS film was 300 nm. The X-ray Diffraction results have shown that all thin films were polycrystalline with orientation of 112 and 211 for CIGS thin films and 111 for CdS films. The direct energy gaps for CIGS and CdS thin films were 1.85 and 2.4 eV, respectively. Atomic Force Microscopy measurement proves that both films CIGS and CdS films have nanostru
... Show MoreA plastic tubes used as absorber of active flat plate solar collector (FPSC) for heating water were studied numerically and experimentally. The set-up is located in Babylon (republic of Iraq) 43.80 East longitude and 32.30 North latitude with titled of 450 toward the south direction. The study involved three dimensions mathematical model for flat coil plastic absorber which solved by FLUENT-ANSYS-R.18 program. Experiments were conducted at outdoor conditions for clear days on January and February 2018 with various water volume flow rates namely (500, 750, 1000, 1250, and 1500 Liter per hour LPH) on each month for Reynolds number range of (1 x 104 to 5 x 104) th
... Show MoreThis paper presents the design, construction and investigates an experimental study of a parabolic Trough Solar Collector (PTSC). It is constructed of multi – piece glass mirror to form the parabolic reflector (1.8 m ? 2.8 m) its form were checked with help of a laser and carbon steel rectangular as receiver. Sun tracker has been developed (using two – axis) to track solar PTSC according to the direction of beam propagation of solar radiation. Using synthetic oil as a heat transfer its capability to heat transfer and load high temperature (?400 oc). The storage tank is fabricated with stainless steel of size 50 L. The experimental tests have been carried out in Baghdad climatic conditions (33.3o N, 44.4o E) during selective days of the
... Show MorePV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building 220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficien
... Show MoreThe present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that cause global warming and greenhouse effect. Flat plate collector was used because it’s easy, ninexpensive and efficient. Many test runs (more than 50) were carried out on the system from May to October, 2013; the main results were taken between the period of July 15, 2013 to August 15, 2013 to find the maximum C.O.P, cooling, temperature and pressure of the system. The system demonstrates a maximum generator temperature of 93.5 oC, on July 18, 2013 at 2:30 pm, and the average mean generator temperature Tgavr was 74.7 °C, for this period. The maximum pressure Pg
... Show MoreIn this study, a theoretical scenario has been used to calculate the electronic current in sensitizer N3 molecule contact to TiO2 semiconductor for electrons in functional solar cells. It is known to play an important role on the compute the eficiency of solar cell. Some parameters of electronic current such as the transition energy, driving force energy, barrier height coupling overlapping values are determined. Transition energy is a necessary parameter to calculate the electronic current in solar cell with using wide polarity solvents Acetic acid, 2-Methoxyethanol, 1-Butanol, Methyl alcohol, chloroform, N,N-Dimethylacetamide and Ethyl alcohol via the quantum donor-acceptor system. Here, we show the results of transition energy can be var
... Show More(3) (PDF) Theoretical calculation of the electronic current at N3 contact with TiO2 solar cell devices. Available from: https://www.researchgate.net/publication/362780274_Theoretical_calculation_of_the_electronic_current_at_N3_contact_with_TiO2_solar_cell_devices [accessed May 01 2023].