This study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices and subsequently optimized using Particle Swarm Optimization (PSO) and the Cheetah Optimizer (CO). The optimized controllers are referred to as PSO-PID and CO-PID, respectively. The error standard used for the electro-hydraulic elevator control system is the Integral Time-weighted Absolute Error (ITAE) type. This study addresses the need to improve dynamic performance and control accuracy in electro-hydraulic elevator systems under maximum load conditions. Experimental results obtained under a 30 kg load for the displacement response showed that PSO-PID reduced rise time by 36.8% and settling time by approximately 37.2% while improving steady-state accuracy by nearly 80% compared with the conventional PID. The CO-PID controller further improved performance, achieving additional reductions of 13.6% in rise time and 13.8% in settling time relative to PSO-PID, as well as decreasing steady-state error by 37.5%. Overall, CO-PID achieved substantial reductions in rise and settling times (up to 45.4% and 45.7%, respectively) and improved steady-state accuracy by nearly 87% compared with the traditional PID. In pressure control loops, PSO-PID reduced settling time by up to 12.8%, whereas CO-PID achieved up to 16.4% faster stabilization relative to the conventional PID. The experimental results were in agreement with the developed MATLAB/Simulink model, confirming the high accuracy of the simulation in representing the system dynamics. These findings demonstrate the superior responsiveness, stability, and efficiency of the CO-PID controller for electro-hydraulic elevator applications.
The standard formulation of Wave Intensity Analysis (WIA) assumes that the flow velocity (U) in the conduit is <;<; the velocity of propagation of waves (c) in the system, and Mach number, M=U/c, is negligible. However, in the large conduit arteries, U is relatively high due to ventricular contraction and c is relatively low due to the large compliance; thus M is > 0, and may not be ignored. Therefore, the aim of this study is to identify experimentally the relationship between M and the reflection coefficient in vitro. Combinations of flexible tubes, of 2 m in length with isotropic and uniform circular cross sectional area along their longitudinal axes, were used to present mother and daughter tubes to produce a range of reflection coeffic
... Show MoreThis paper describes a new finishing process using magnetic abrasives were newly made to finish effectively brass plate that is very difficult to be polished by the conventional machining processes. Taguchi experimental design method was adopted for evaluating the effect of the process parameters on the improvement of the surface roughness and hardness by the magnetic abrasive polishing. The process parameters are: the applied current to the inductor, the working gap between the workpiece and the inductor, the rotational speed and the volume of powder. The analysis of variance(ANOVA) was analyzed using statistical software to identify the optimal conditions for better surface roughness and hardness. Regressions models based on statistical m
... Show MoreAbstract
Much attention has been paid for the use of robot arm in various applications. Therefore, the optimal path finding has a significant role to upgrade and guide the arm movement. The essential function of path planning is to create a path that satisfies the aims of motion including, averting obstacles collision, reducing time interval, decreasing the path traveling cost and satisfying the kinematics constraints. In this paper, the free Cartesian space map of 2-DOF arm is constructed to attain the joints variable at each point without collision. The D*algorithm and Euclidean distance are applied to obtain the exact and estimated distances to the goal respectively. The modified Particle Swarm Optimization al
... Show MoreCommunity detection is an important and interesting topic for better understanding and analyzing complex network structures. Detecting hidden partitions in complex networks is proven to be an NP-hard problem that may not be accurately resolved using traditional methods. So it is solved using evolutionary computation methods and modeled in the literature as an optimization problem. In recent years, many researchers have directed their research efforts toward addressing the problem of community structure detection by developing different algorithms and making use of single-objective optimization methods. In this study, we have continued that research line by improving the Particle Swarm Optimization (PSO) algorithm using a
... Show MoreElectro coagulation treatment was used for zinc removal from electroplating wastewater of the State Company for Electrical Industries . This wastewater, here consists zinc ions with maximum concentration in solution of 90 ppm .
The parameters that influenced the wastewater treatment are: current density in the range 1-1.4 mA/cm2, pH in the range 5-10, temperature in the range 25-45°C and time in the range 10-180 minute.
The research is a laboratory experimental type using batch system for electrical process with direct current. The cell comprised of aluminum electrode as anode and stainless steel electrode as cathode. Thirty experiments and one hundred fifty sample lab tests were carried out in this research
... Show MoreThis work is concerned with the vibration attenuation of a smart beam interacting with fluid using proportional-derivative PD control and adaptive approximation compensator AAC. The role of the AAC is to improve the PD performance by compensating for unmodelled dynamics using the concept of function approximation technique FAT. The key idea is to represent the unknown parameters using the weighting coefficient and basis function matrices/vectors. The weighting coefficient vector is updated using Lyapunov theory. This controller is applied to a flexible beam provided with surface bonded piezo-patches while the vibrating beam system is submerged in a fluid. Two main effects are considered: 1) axial stretching of the vibrating beam that leads
... Show MoreThe present work aimed to study the efficiency of nanofiltration (NF) and reverse osmosis (RO) membrane for heavy metal removal from wastewater and study the factors affecting the performance of these two membranes: feed concentrations for heavy metal ions, pressure, and flow rate. The experimental results showed, heavy metals concentration in permeate increase with raise in feed concentrations, decline with increase in flow rate. The raise of pressure, heavy metals concentration decreases for RO membrane, but for NF membrane the concentration decrease and then at high pressure increase. The rejection percentage for chromium in NF and RO is 99.7% and 99.9%, for copper is 98.4% and 99.3%, for zinc is 97.9% and 99.5%, for nickel is 97.2% and
... Show MoreIn this work, the effect of the addition of bright nickel plating and silver carried out by the electroplating method has been studied, on the coating of copper nanoparticles on the copper base metal via the process of thermal evaporation. The improvement of the solar absorber using CuNP in combination with the bright nickel and silver was obtained to be better than copper nanoparticles individually. A bright nickel enhanced the absorbed thermal stability. Also, other optical properties, absorptions, and emissivity slightly decreased from (93% to 87%), while the existence of silver had a slight impact on absorption of about (86.50%). On the other hand, thermal conductivity was evaluated using hot disk analyzer. The results showed a good
... Show MoreA comparative study was carried out on ecological and genetical adaptation of three Iraqi
freshwater snails, Physa acuta, Melanopsis buccinoidea and Melanoides tuberculata, in
respect to acute toxicity of heavy metals (Zn, Cd and Hg). Longevity are used as poisoning
tolerance criterion. LT 50 and LT 100 were determined for the studied snails at (0.5, 1, 5, and
10 ppm), for the three metals. Results indicated that Physa acuta had a higher tolerance than
Melanopsis buccinoidea and Melanoides tuberculata, which was the lower one. Previous
exposure to heavy metals in the original habitat was affecting on experimental tolerance and
no relationships of physical and chemical factors (total hardness, temperature, D. O. and