Preferred Language
Articles
/
dXgp4qABuRolNscL8_Tb
Experimental Optimization of PLC-Integrated Multi-Loop PID Control for a Three-Level Electro-Hydraulic Elevator Using PSO and Cheetah Optimizer
...Show More Authors

This study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices and subsequently optimized using Particle Swarm Optimization (PSO) and the Cheetah Optimizer (CO). The optimized controllers are referred to as PSO-PID and CO-PID, respectively. The error standard used for the electro-hydraulic elevator control system is the Integral Time-weighted Absolute Error (ITAE) type. This study addresses the need to improve dynamic performance and control accuracy in electro-hydraulic elevator systems under maximum load conditions. Experimental results obtained under a 30 kg load for the displacement response showed that PSO-PID reduced rise time by 36.8% and settling time by approximately 37.2% while improving steady-state accuracy by nearly 80% compared with the conventional PID. The CO-PID controller further improved performance, achieving additional reductions of 13.6% in rise time and 13.8% in settling time relative to PSO-PID, as well as decreasing steady-state error by 37.5%. Overall, CO-PID achieved substantial reductions in rise and settling times (up to 45.4% and 45.7%, respectively) and improved steady-state accuracy by nearly 87% compared with the traditional PID. In pressure control loops, PSO-PID reduced settling time by up to 12.8%, whereas CO-PID achieved up to 16.4% faster stabilization relative to the conventional PID. The experimental results were in agreement with the developed MATLAB/Simulink model, confirming the high accuracy of the simulation in representing the system dynamics. These findings demonstrate the superior responsiveness, stability, and efficiency of the CO-PID controller for electro-hydraulic elevator applications.

Scopus Crossref
View Publication
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Optimization Procedures using Effect of Etalon Finesse and Driving Term on Optical Bistability
...Show More Authors

        In this work, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). Because of a trade off between the etalon finesse values and driving terms, an optimization procedures have been done on the InSb etalon/CO laser parameters, using critical switching irradiance (Ic) via simulation systems of optimization procedures of optical cavity. in order to achieve the  minimum switching power and faster switching time, the optimization parameters of the finesse values and driving terms on optical bistability and switching dynamics must be studied.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Nov 14 2024
Journal Name
Journal Of Emergency Medicine, Trauma And Acute Care
Novel isolation and optimization of anti-MRSA bacteriophages using plaque-based biokinetic methods
...Show More Authors

Background: MRSA (methicillin-resistant Staphylococcus aureus) is a global health problem. Many people are looking for new ways to combat MRSA, for example by using bacteriophages (phages). It has been extremely challenging to isolate a sufficient quantity of lytic anti-MRSA phages. Therefore, new techniques for separating, refining, and reworking anti-MRSA phages were sought in this study.

Methods: Of 437 S. aureus isolates, nine clinical MRSA isolates were obtained from three hospitals in Baghdad, Iraq and two ATCC MRSA strains were used to separate wild anti-MRS

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
GEOMETRY OPTIMIZATION OF COUPLING ALLIN -METFORMIN USING DFT/B3LYP MOLECULAR MODELLING TECHNIQUE: GEOMETRY OPTIMIZATION OF COUPLING ALLIN -METFORMIN USING DFT/B3LYP MOLECULAR MODELLING TECHNIQUE
...Show More Authors

This researchpaper includes the incorporation of Alliin at various energy levels and angles 

With Metformin using Gaussian 09 and Gaussian view 06. Two computers were used in this work. Samples were generated to draw, integrate, simulate and measure the value of the potential energy surface by means of which the lowest energy value was (-1227.408au). The best correlation compound was achieved between Alliin and Metformin through the low energy values where the best place for metformin to b

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Bulletin Of Electrical Engineering And Informatics
A novel data offloading scheme for QoS optimization in 5G based internet of medical things
...Show More Authors

The internet of medical things (IoMT), which is expected the lead to the biggest technology in worldwide distribution. Using 5th generation (5G) transmission, market possibilities and hazards related to IoMT are improved and detected. This framework describes a strategy for proactively addressing worries and offering a forum to promote development, alter attitudes and maintain people's confidence in the broader healthcare system without compromising security. It is combined with a data offloading system to speed up the transmission of medical data and improved the quality of service (QoS). As a result of this development, we suggested the enriched energy efficient fuzzy (EEEF) data offloading technique to enhance the delivery of dat

... Show More
Publication Date
Sun Oct 01 2023
Journal Name
Bulletin Of Electrical Engineering And Informatics
A novel data offloading scheme for QoS optimization in 5G based internet of medical things
...Show More Authors

The internet of medical things (IoMT), which is expected the lead to the biggest technology in worldwide distribution. Using 5th generation (5G) transmission, market possibilities and hazards related to IoMT are improved and detected. This framework describes a strategy for proactively addressing worries and offering a forum to promote development, alter attitudes and maintain people's confidence in the broader healthcare system without compromising security. It is combined with a data offloading system to speed up the transmission of medical data and improved the quality of service (QoS). As a result of this development, we suggested the enriched energy efficient fuzzy (EEEF) data offloading technique to enhance the delivery of dat

... Show More
View Publication
Scopus (14)
Crossref (5)
Scopus Crossref
Publication Date
Fri Aug 21 2026
Journal Name
Journal Of Intelligent Decision Making And Information Science
A Key-Dependent Dynamic S-box for the ASCON Lightweight Cipher with a Dual Acceptance Filter and Population-Level Evaluation
...Show More Authors

Communication between unmanned aerial vehicle (UAV) swarms and flying ad-hoc networks is critical and challenging since it is over open radio networks and energy, memory and processing budgets are severely constrained. Lightweight cryptography is the solution and ASCON — the NIST standard for lightweight authenticated encryption — has become a popular option for securing UAV links at a fraction of the energy cost of AES. The security of ASCON relies on one nonlinear device — 5-bit substitution box (S-box). However, this S-box is fixed and publicly known, and allows an adversary to precompute the cryptographic properties one time and then reuse them against all the protected traffic, and moreover, it does not meet the strict av

... Show More
View Publication
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Plant Archives
Schistosomiasis vector control using cucumis melo plantextractswithbioassayexperiment
...Show More Authors

he aim of this study is to get a plant extracts to use it as molluscicides to control the snail vector of Schistosomiasis andfinely control the disease. Laboratory study was performed to compare the molluscicidal activity of leaves and stems extractsof Cucumis melo against Bulinus truncatus snail. The snail B. truncatus was exposed to a serial concentrations of leaves andstems extracts (4000ppm, 5000ppm) in this work. Different effects of the extracts to the snail B. truncatus were recorded.These effects includes death, escaping and imbalance of snail behavior. 96hr-LD50 values of leaves extracts were calculatedfor the doses 4000 and 5000ppm as (76 and 37%) respectively while for stems were (105 and 47%) respectively. We found thatthe snail

... Show More
View Publication
Scopus
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of The World Federation Of Orthodontists
Validity and reliability of three-dimensional modeling of orthodontic dental casts using smartphone-based photogrammetric technology
...Show More Authors

View Publication
Scopus (10)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of The Mechanical Behavior Of Materials
Groundwater flow modeling and hydraulic assessment of Al-Ruhbah region, Iraq
...Show More Authors
Abstract<p>Al-Ruhbah region is located in the southwest of Najaf Governorate. A numerical model was created to simulate groundwater flow and analyze the water quality of the groundwater, by developing a conceptual model within the groundwater modeling system software. Nineteen wells were used, 15 for pumping and four for observation. A three-dimensional model was built based on the cross-sections indicating the geologic layers of the study area, which were composed of five layers. When a distance of 1,000 m between the wells was adopted, 135 wells can be operated simultaneously. These wells were hypothetically operated at 6, 12, and 18 h intervals, with a discharge of 200, 430, and 650 m<j></j></p> ... Show More
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Determination of Mono-crystalline Silicon Photovoltaic Module Parameters Using Three Different Methods
...Show More Authors

For modeling a photovoltaic module, it is necessary to calculate the basic parameters which control the current-voltage characteristic curves, that is not provided by the manufacturer. Generally, for mono crystalline silicon module, the shunt resistance is generally high, and it is neglected in this model. In this study, three methods are presented for four parameters model. Explicit simplified method based on an analytical solution, slope method based on manufacturer data, and iterative method based on a numerical resolution. The results obtained for these methods were compared with experimental measured data. The iterative method was more accurate than the other two methods but more complexity. The average deviation of

... Show More
View Publication Preview PDF