Preferred Language
Articles
/
dRhue5UBVTCNdQwCPS7z
The Effect of Two Bonding Agents Generations On Microleakage Of Composite Resin Using Two Light Curing Systems.
...Show More Authors

Aim: To evaluate the effect of two bonding systems and two curing systems on sealing ability of class V composite restorative materials. Materials and methods: This study was performed in vitro on 40 caries free upper first premolar teeth. The Standardized class V cavity preparation on buccal and lin- gual surfaces of each tooth was done. Then the teeth were randomly divided into two major groups each of twenty. 40 cavities were performed on these teeth and the first group7th generation bonding agent (i Bond) were applied according to the manufacturer instructions and single increment of univer- sal composite (XRV Herculite) from kerr were applied and twenty of the cavities were cured with con- ventional light cure device (astralis-5) and the other twenty cavities were cured with a LED. While the second group 5th generation (Excite bonding agent) applied according to the manufacturer instructions. And filled with universal composite (tetric).Twenty of the cavities light cured with conventional light cure device and the other twenty cavities cured with LED light cured device. Then the teeth were stored in normal physiological saline in an incubator at (37Co) half of each sub group (10 cavities) were stored for one day and the second half stored for one week. Then the teeth were thermo cycled for (200) cycles, after thermo cycling all teeth were immersed in a freshly prepared solution of 2% methylene blue for (24) hours at (37Co). Results: The results showed that there was no statistically significant difference between samples cured using conventional light curing system and those cured using LED light curing system. The type of bonding system and composite material used in this study had no sig- nificant effect on reducing microleakage. Samples aged for seven days produced significantly higher levels of microleakage than that for one day. Conclusions: All samples in this study showed microlea- kage with different levels. Microleakage increases as the age increases. Neither the types of light curing system nor the types of bonding were able to reduce microleakage.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparison between the Horizontal Condylar and Bennett Angles of Iraqi Full Mouth Rehabilitation Patients by Using Two Different Articulator Systems (An In-Vivo Study)
...Show More Authors

Background: Errors of horizontal condylar inclinations and Bennett angles had largely affected the articulation of teeth and the pathways of cusps. The aim of this study was to estimate and compare between the horizontal condylar (protrusive) angles and Bennett angles of full mouth rehabilitation patients using two different articulator systems. Materials and Methods: Protrusive angles and Bennett angles of 50 adult males and females Iraqi TMD-free full mouth rehabilitation patients were estimated by using two different articulator systems. Arbitrary hinge axis location followed by protrusive angles and Bennett angles, estimation was done by a semiadjustable articulator system. A fully adjustable articulator system was utilized to locate th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
Effect of Steering Wheel Vibration on drivers Hands in a Two-Wheel Drivers Hand tractor
...Show More Authors

The paper presents research results of the vibration transmitted from the steering wheel of the
tractor with a 2-wheel drive to the driver’s hands. The vibration measurements were carried out on the
tractor randomly chosen from the collage of agriculture / university of Baghdad. Before testing the
tractor was examined and adjusted following the producer’s recommendations. The vibration levels
were measured during the operation tillage at idling and at full load .The field was 3١٫٧ m above level
sea. Soil was treated at soil constant moisture (1٧-20 %) with depth of plowing (١٧ cm). During
operation the weather temperature was measured (15 C) and humidity was ( 27 % ) The vibration level
on the steering whee

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 17 2011
Journal Name
Journal Of Engineering
Effect of Steering Wheel Vibration on drivers Hands in a Two-Wheel Drivers Hand tractor
...Show More Authors

The paper presents research results of the vibration transmitted from the steering wheel of the tractor with a 2-wheel drive to the driver’s hands. The vibration measurements were carried out on the tractor randomly chosen from the collage of agriculture / university of Baghdad. Before testing the tractor was examined and adjusted following the producer’s recommendations. The vibration levels were measured during the operation tillage at idling and at full load .The field was 31.7 m above level sea. Soil was treated at soil constant moisture (17-20 %) with depth of plowing (17 cm). During operation the weather temperature was measured (15 C) and humidity was ( 27 % ) The vibration level on the steering wheel was measured and analyzed .T

... Show More
Preview PDF
Publication Date
Wed Oct 23 2019
Journal Name
Iraqi Journal Of Agricultural Sciences
EXTRACTION OF JOJOBA OIL USING VARIOUS CONCENTRATIONS OF TWO DIFFERENT SOLVENTS
...Show More Authors

The aim of this study was extraction of jojoba oil using different solvents. A mixture of waterhexane and water-ethanol are used as solvents to extract jojoba oil in a batch extraction process and compared with a pure solvent extraction process. The effects of particle size of crushed seeds, solvent-to-water ratio and time on jojoba oil extraction were investigated. The best recovery of oil was obtained at the boiling temperature of the solvent and four hour of extraction time. When seed particle size was 0.45 mm and a pure ethanol was used (45% yield of oil extraction), whereas, it was 40% yield of oil at 25% water-hexane mixture. It was revealed that the water-ethanol and water-hexane mixtures have an effect on the oil extraction yield. T

... Show More
Crossref
Publication Date
Wed Aug 16 2023
Journal Name
مجلة الاستاذ للعلوم الانسانية والاجتماعية- كلية التربية ابن رشد – جامعة بغداد،
Using the Theory of Conceptual Metaphor in Two Sonnets by Victorian Female Poets
...Show More Authors

This study has applied the theoretical framework of conceptual metaphor theory to the analysis of the source and target domains of metaphors that are used in two English nineteenth century sonnets, both written by contemporaneous female poets. The quantitative and qualitative results of the textual analysis have clearly revealed that Elizabeth Barrett Browning’s sonnet 23 centres around the conceptual mapping of the journey of love and life with that of possession. In contrast, Christina Rossetti’s sonnet Remember tackles the central conceptual mapping of death as a journey in relation to its further experiential connections. In addition, the application of conceptual metaphor theory in identifying the frequencies and densities of metap

... Show More
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Comparison of Fatigue Life Behavior between Two Different Composite Materials Subjected to Shot Peening at Different Times
...Show More Authors

This paper investigated the fatigue life behavior of two composite materials subjected to different times of shot peening (2, 4 and 6 min).The first material prepared from unsaturated polyester with E-glass reinforcement by 33% volume fraction. While, the second one was prepared from unsaturated polyester with aluminum powder by2.5% volume fraction. The experimental results showed that the improvement in endurance limit was obtained (for the first material) at 2, 4 and 6 min shot peening times where the percentage of maximum improvement was 25% at shot peening time of 6 min. While, the endurance limit of the second material decreased at shot peening times of 2, 4 and 6 min where the percentage of maximum reduction was 29 % at shot peenin

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Operative Dentistry
Interfacial Bond Strength and Morphology of Sound and Caries-affected Dentin Surfaces Bonded to Two Resin-modified Glass Ionomer Cements
...Show More Authors
SUMMARY<sec> <title>Objective

To evaluate the shear bond strength and interfacial morphology of sound and caries-affected dentin (CAD) bonded to two resin-modified glass ionomer cements (RMGICs) after 24 hours and two months of storage in simulated body fluid at 37°C.

Methods and Materials

Sixty-four permanent human mandibular first molars (32 sound and 32 with occlusal caries, following the International Caries Detection and Assessment System) were selected. Each prepared substrate (sound and CAD) was co

... Show More
View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
The Effect of metals as Additives on Thermal conductivity of Epoxy Resin
...Show More Authors

A hand lay-up method was used to prepare Epoxy/ metal composites. Epoxy resin (EP) was used as a matrix with metal particles (Al, Cu, and Fe) as fillers.
The preparation method includes preparing square panels of composites with different weight percentage of fillers (10, 20, 30, 40, and 50%). Standard specimens (88mm in diameter) for thermal conductivity tests were prepared to measure thermal conductivity kexp.The result of experimental thermal conductivity kexp, for EP/metal composites show that, kexp increase with increasing weight percentage, For EP/ Al and EP/Cu composites, and it have have maximum values of 0.33 and 0.35 W/m.K, respectively. While kexp for EP/ Fe composite show slight increase with maximum value of 0.186 W/m.K.

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
The Effect of metals as additives on adhesion properties of epoxy resin
...Show More Authors

EP/ metal composites were prepared as adhesives between two steel rods. Epoxy resin (EP) was used as a matrix with metal as fillers (Al, Cu, Fe,).
The preparation method for tensile adhesion tests includes two steel rods with adhesive composites between the rods to measure adhesion strength Sad and adhesion toughness Gad.
Results of tensile adhesion tests show that EP/ metals composite have maximum strength Sad for certain weight percentage of metals 2.95 and 9MPa at 10% for EP/Al and EP/Cu composite and 8.2MPa at 40% for EP/Fe composites

View Publication Preview PDF
Publication Date
Sat Dec 31 2011
Journal Name
Al-khwarizmi Engineering Journal
The Estimation of Vibrational Energy of Two Coupled (Welded) Plates Using Statistical Energy Analysis
...Show More Authors

 

This paper deals with a method called Statistical Energy Analysis that can be applied to the mechanical and acoustical systems like buildings, bridges and aircrafts …etc. S.E.A as a tool can be applied to the resonant systems in the circumstances of high frequency or/and complex structure». The parameters of S.E.A such as coupling loss factor, internal loss factor, modal density and input power are clarified in this work ; coupled plate sub-systems and explanations are presented for these parameters. The developed system is assumed to be resonant, conservative, linear and there is an equipartition of energy between all the resonant modes within a given frequency band in a given sub-system. The aim of th

... Show More
View Publication Preview PDF