Breast cancer is the most common malignancy affecting women's health, with an increasing incidence worldwide. This study aimed to measure the intracellular concentration of the hypoxia-inducible factor 1 α (HIF-1α), tumor suppression protein p53, and estradiol (E2) in tumor tissues of adult females with breast cancer and their relation to tumor grade, tumor size, and lymph node metastases (LNM). The study was conducted on 65 adult female participants with breast mass admitted to the operating theater in Al-Hussein Teaching Hospital and Al-Habboby Teaching Hospital in Nasiriyah, Iraq, from January to November 2021. Fresh breast tumor tissues were collated and homogenized for intracellular biochemical analysis using the enzyme-linked immunosorbent assay method. In total, 44 (58%) out of 65 patients, in the age range of 18-42 years and the mean±SD age of 32.55±6.40 years, had fibroadenomas, and other 21 (42%) cases, in the age range of 32-80 years and the mean±SD age of 56±14.4 years had invasive ductal carcinoma (IDC) breast cancer. Intracellular levels of HIF-1α, p53, and E2 were elevated significantly (P<0.001) in IDC cases compared to the benign group. The most malignant tumors of IDC cases were in grade III and sizes T2 and T3. The tissue concentrations of HIF-1α, P53, and E2 were significantly elevated in patients with tumor stage T3 compared to T2 and T1. A significant elevation was found in the levels of HIF-1α, p53, and E2 in the positive LNM subgroup compared to the negative LNM group. Based on the obtained results, the prognostic value of the intracellular HIF-1α is considered to be a useful prognostic factor in Iraqi women with ICD and the combination of a HIF-1α protein with the nonfunctional p53 and E2 tends to indicate the proliferation, invasiveness, and metastases of the breast tumors.
Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes
... Show MoreReverse Phase High Performance Liquid Chromatography (RP-HPLC) was coupled with ultraviolet absorption sepectoscopy (UV) for separation and identification of Naphthalene, Acenaphthylene, Pyrene, Benz{a} anthracene and 1,3,2,4-Dibenzanthracene. RP-HPLC was performed on an ODS-C18 column (150×4.6 mm I.D) using acetonitrile–buffer phosphate as mobile phase. UV absorption spectra of the elutes was detected in 254 nm, and studying the chromatographic variables include organic modifier ratio, PH, column temperature and concentration of buffer to maximize resolution and minimize separation time. the results showed that using mobile phase( 80:20) v/v acetonitrile:0.01M phosphate buffer solution at PH 6 with flow rate 1ml/min and column te
... Show MoreBackground: Tumors of the oral cavity are under
estimated in general dental and medical practice,
some authors describe it as the forgetting disease,
others wondering if the attention paid to this disease
compared to its fatality (The 5-year survival rate is
about 50%) is enough for disease control? However;
this disease deserves a comprehensive assessment by
all dental and medical fields assumed to examine the
oral cavity regularly, especially otolaryngologist.
Objectives: To find out the sensitivity and specificity
of clinical examination in diagnosing oral tumors and
premalignant conditions by otolaryngologist.
Methods: Across sectional retrospective study was
conducted in the:
-study design:
abstract:
The aim of this study is to clarify the relationship between the concept of inconsistency and the measurement of the inverse relationship of overlap and contrast. The study will address the following points:
- Explaining the true nature of inconsistency and contrast, as understanding their relationship is essential for determining them.
- Examining the view of the scholars regarding their significance as approaches to understanding the relationship.
- Identifying the relationship between inconsistency and contrast in terms of overlap and contrast.
The Prophet Muhammed () is distinguished in the history of mankind by the fact that he came with a law that combined these two opposing sides, reality and ideals, a wonderful and amazing collection, and he created a wonderful composition between them, and they used together a wise comprehension to ensure the treatment of its ills, and the reform of their delusions together, and uses both Both of them are in the necessary position of the needs of life, and the contradictions and separation of this collection and the wise harness in this research from his law, may God bless him and grant him peace, which shows us this balance in the system of Islam, the most sincere representation, where it is one of the honors of morality, good appreci
... Show MoreD-mannose sugar was used to prepare [benzoic acid 6-formyl-2,2-dimethyl-tetrahydrofuro[3,4-d][1,3]dioxol-4-yl ester] (compound A). The condensation reaction of folic acid with (compound A) resulted in the formation of new ligand [L]. These compounds were characterized by elemental analysis CHN, atomic absorption A.A, (FT-I.R.), (U.V.-Vis), TLC, E.S. mass (for electrospray), molar conductance, and melting point. The new tetradentate ligand [L], reacted with two moles of some selected metal ions and two moles of (2-aminophenol), (metal : ligand : 2-aminophenol) at reflux in water medium to give a series of new complexes of the general formula K2[M2(L)(HA)2] where M= Co(II), Ni(II), Cu(II) and Cd(II). These complexes were characterized by elem
... Show MoreA new spectrophotometric method for individual and simultaneous determination of cefixime and cephalexin depending on the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of cefixime and cephalexin in concentration interval of (4– 24μg.ml-1 ) by measuring the amplitude of peak-to-base line, pea to peak at certain wavelengths and the area under peak at selected spectrum intervals. The methods showed reasonable precision and accuracy and have been applied to determine cefixime and cephalexin in two different pharmaceutical preparations.
.Curcumin (Cur) and L phenylalanine (Phy) compounds were used to prepare two mixed ligand complexes with Cr (III) and Fe (III) ions. The synthesized complexes are characterized by using conductivity measurement and different spectral methods like FT-IR and UV- Vis .Molar conductance and analytical studies confirmed that the complexes exhibit octahedral geometry., suggest that the complexes are formed in 1: 1 :2 [ L : Metal : 2phe ] ratio and they proposed to have the general formulae [M(Cur)(phe)2] Cl (M= Cr (III) and Fe (III) The compound dyeing method was studied and applied to acrylic fabric.The antibacterial activity of curcumin, phenylalanine and their mixed ligand complexes were examined on pathogenic bacterial strains and showed good
... Show MoreThis study focused on two areas in AL-Najaf city, AL-Ruhbah and Al-Haydariyah regions because of the importance and widespread use of groundwater in these areas. The two areas were compared quantitatively and qualitatively. For the quantitative approach, the GMS software was used in conjunction with the GIS software to simulate the groundwater flow behavior. The solid model for both areas was created, the geological formation was determined, and the hydraulic properties were identified using GMS software. To test the quantity of groundwater in both areas, the wells have been redistributed to a distance of 2000 m between them, and a period of 1000 days was chosen. When a discharge of 10 l/s and operation times of 4, 8, an
... Show More