Preferred Language
Articles
/
dRb3DIcBVTCNdQwCszNx
Response of Damaged Reinforced Concrete Beams Strengthened with NSM CFRP Strips
...Show More Authors

This paper presents a study (experimentally) for strengthening reinforced concrete (RC) beams with Near-Surface-Mounted (NSM) technique. The use of this technique with CFRP strips or rebars is an efficient technology for increasing the strength for flexure and shear or for repairing damaged reinforced concrete (RC) members. The objective of this research is to study, experimentally, RC beams either repaired or strengthened with NSM CFRP strips and follow their flexural behavior and failure modes. NSM-CFRP strips were used to strengthen three RC beam specimens, one of them was initially strengthened and tested up to failure. Four beam specimens have been initially subjected to preloading to 50% and 80% of ultimate load. Two of the specimens were either repaired or strengthened with NSM-CFRP strips. All the repaired/strengthened pre-damaged beams have been tested up to failure by using compression-testing machine. An appropriate-scale model was adopted. All the specimens have a cross-sectional dimension of 150 mm with an effective span of 110 mm. Depends on the experimental results, a better performance of the strengthened concrete specimens was obtained in both strength and serviceability. As a comparison with the control beam specimen, all the repaired specimens show a very good increase of about 40% in the load-carrying capacity and a high improvement in resistance to cracking of about 120% in NSM. On the other hand, the test results of NSM CFRP-strengthened concrete specimens with a preloading of 50% and 80% of the ultimate load show an increase of about 9% to 20% in the load-carrying capacity, for 50% and 80% pre-loading, respectively an improvement in deflection of about 2% to 27% in NSM, for 80% and 50% pre-loading, respectively.

Crossref
View Publication
Publication Date
Fri Mar 04 2022
Journal Name
Baghdad Science Journal
Fusion Reaction Study of some Selected Halo Systems
...Show More Authors

The challenge in studying fusion reaction when the projectile is neutron or proton rich halo nuclei is the coupling mechanism between the elastic and the breakup channel, therefore the motivation from the present calculations is to estimate the best coupling parameter to introduce the effect of coupled-channels for the calculations of the total cross section of the fusion , the barrier distribution of the fusion and the average angular momentum ⟨L⟩ for the systems 6He+206Pb, 8B+28Si, 11Be+209Bi, 17F+208Pb, 6He+238U, 8He+197Au and 15C+232Th using quantum mechanical approach. A quantum Coupled-Channel Calculations are performed using CC code. The predictions of quantum mechanical approach are comparable with the measured data that is

... Show More
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Mathematics Research
Effect of Some Geometric Transfers on Homology Groups
...Show More Authors

Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Oscillation of Nonlinear First Order Neutral Differential Equations
...Show More Authors

In this paper, the author established some new integral conditions for the oscillation of all solutions of nonlinear first order neutral delay differential equations. Examples are inserted to illustrate the results.

View Publication Preview PDF
Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Cubic Of Positive Implicative Ideals In KU- Semigroup
...Show More Authors

In this paper, we define a cubic positive implicative-ideal, a cubic implicative-ideal and a cubic commutative-ideal of a semigroup in KU-algebra as a generalization of a fuzzy (positive implicative-ideal, an implicative-ideal and a commutative-ideal) of a semigroup in KU-algebra. Some relations between these types of cubic ideals are discussed. Also, some important properties of these ideals are studied. Finally, some important theories are discussed. It is proved that every cubic commutative-ideal, cubic positive implicative-ideal, and cubic implicative-ideal are a cubic ideal, but not conversely. Also, we show that if Θ is a cubic positive implicative-ideal and a cubic commutative-ideal then Θ is a cubic implicative-ideal. Some example

... Show More
View Publication
Crossref
Publication Date
Sun Apr 12 2009
Journal Name
Journal Of Engineering
Correlations of Reservoir Rock Properties from Well Measurements
...Show More Authors

Publication Date
Thu Jan 10 2019
Journal Name
Journal Of The College Of Education For Women
The provisions of the autistic in criminal penalties
...Show More Authors

  Thankfully Thank meets the grace and pushes us Blaneh and a curse, peace and blessings be upon the Prophet after him, and his family and companions, and after:

    This research deals with the subject of the provisions of the autistic in criminal penalties, one of the important issues, especially after the spread in abundance in our contemporary society, as the patient is characterized by autism in most of spaces of isolation and depression and aggressive behavior, and in some cases try autistic to commit suicide as a result of going through the psychological pressure , was this research to clarify what follows autistic criminal penalties as a result of the capital crime of self or without them, and the stat

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2012
Journal Name
2012 8th International Conference On Wireless Communications, Networking And Mobile Computing
Performance Evaluation of Location Management in GSM Networks
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref
Publication Date
Thu Aug 10 2023
Journal Name
Central Asian Journal Of Medical And Natural Sciences
Role of Gamma Camera Components in Radiological Diagnosis
...Show More Authors

The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photom

... Show More
Publication Date
Mon Dec 01 2025
Journal Name
Egyptian Journal Of Microbiology
Role Of Preoperative Prophylaxis Antibiotics In Fracture Mandible
...Show More Authors

View Publication
Crossref
Publication Date
Mon Apr 26 2021
Journal Name
Journal Of Real-time Image Processing
Fast and efficient recursive algorithm of Meixner polynomials
...Show More Authors

View Publication
Scopus (33)
Crossref (29)
Scopus Clarivate Crossref