Preferred Language
Articles
/
cxZpuosBVTCNdQwCE9jr
Detection of Mineral and Microbial Contaminants in some Types of Imported Meat
...Show More Authors
Abstract<p>The main target of the current study is to investigate the microbial content and mineral contaminants of the imported meat available in the city of Baghdad and to ensure that it is free from harmful bacteria, safe and it compliances with the Iraqi standard specifications. Some trace mineral elements such as (Iron, Copper, Lead, and Cadmium) were also estimated, where 10 brands of these meats were collected. Bacteriological tests were carried out which included (total bacterial count, <italic>Staphylococcus</italic> bacteria, <italic>Salmonella</italic> bacteria). The results showed highest number of total bacterial count 13×10<sup>5</sup> CFU/g in F8 brand, while the lowest number of bacteria 5×101 CFU/g in F3 brand. However, <italic>Staphylococcal</italic> bacteria showed the highest number of 66×10<sup>2</sup> CFU/g in F7 brand, while the lowest number of <italic>Staphylococcal</italic> bacteria amounted to 1×10<sup>1</sup> CFU/g in F9 brand. The number of <italic>Salmonella</italic> bacteria in imported meat samples, the two brands contained <italic>Salmonella</italic> bacteria were (F2, F7), while the other brands were free of <italic>Salmonella</italic> bacteria. The results showed that the highest concentration of Cu was 1.658 μg/g in F7 brand, whereas the lowest concentration of Cu was in F6 brand amounting to 0.093 μg/g. However, highest concentration of Pb reached 0.040 μg/g in F6 brand, while the lowest concentration of Pb was recorded in F2 brand reaching 0.002 μg/g. Furthermore, the highest concentration of Cd was 0.004 μg/g in F7 brand whereas the lowest detected concentration of Cd was in (F1, F4, F5, F9, and F10) brands reaching 0.000 μg<sup>/</sup>g.</p>
Scopus Crossref
View Publication
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Use of cefoxitin as indicator for detection of Methicillin Resistant Staphylococcus aureus
...Show More Authors

Rapid and accurate identification of Methicillin Resistant Staphylococcus aureus is essential in limiting the spread of this bacterium. The aim of study is the detection of Methicillin Resistant Staphylococcus aureus (MRSA) and determining their susceptibility to some antimicrobial agent. A total of fifty clinical Staphylococcus aureus, isolated from the nose of health work staff in surgery unit of Kalar general hospital and from ear of patients attended to the same hospital. The susceptibilities of isolates were determined by the disc diffusion method with oxacillin (1 ?g) and cefoxitin (30 ?g), and by the mannitol salt agar supplemented with cefoxitin (MSA-CFOX), susceptibilities of isolates to other antimicrobial agent were determined b

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 27 2018
Journal Name
Mustansiria Dental Journal
The Effect of Modified Carisolv Gel on Surface Roughness of two Different Types of Ceramic Materials Using Light Polarizing Microscope
...Show More Authors

This in vitro study evaluated the influence of chemomechanical caries removal solution on the surface topography of metal-ceramic feldspar porcelain (MAJOR ceramic) and All-ceramic feldspar porcelain (Vita Alpha) using light polarizing microscope. Forty specimens of MAJOR ceramic and forty specimens of Vita Alpha ceramic of (12mm diameter & 3mm height) were prepared .All specimens were polished with silicon polishing burs, cleaned, autoglazed and stored in 37°C before exposure to Carisolv. Thirty specimens of each material randomly exposed to Carisolv gel for 5, 10 and 20 minutes respectively, other ten specimens were not, to act as control group. All specimens were subjected to surface roughness test by profilometer and evalua

... Show More
View Publication
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Brazilian Dental Science
The Effect of Immediate Dentin Sealing on the Marginal Adaptation of LithiumDisilicate Overlay Restorations using different types of luting agents
...Show More Authors

Objective: This study evaluated the effect of immediate dentin sealing on the marginal adaptation of lithium disilicate overlays with three different types of resin-luting agents: preheated composite, dual-cure adhesive resin, and flowable composite. Materials and Methods: Forty-eight maxillary first premolars of similar size were prepared with a butt joint preparation design. The teeth were separated into two primary groups, each with twenty-four teeth: Group DDS: Delay dentin sealing (non-IDS) teeth were not treated. Group IDS: dentin sealing was applied immediately after teeth preparation. Each group was subsequently separated into three separate subgroups. Subgroups (DDS+Phc, IDS+Phc): cemented with preheated composite (Enamel plus HRi,

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat Nov 29 2025
Journal Name
Iraqi Journal Of Biotechnology
DETECTION OF GENE EXPRESSION OF SERINE PALMITOYLTRANSFERASE (SPT2) IN MOUSE CELL LINE RAW264.7 INFECTED WITH LEISHMANIA MEXICANA AMASTIGOTES
...Show More Authors

Leishmania species are the causative agent of a tropical disease known as leishmaniasis. Previous studies on the old world species Leishmania major, showed that the amastigotes form which resides inside the macrophage of the vertebrate host, utilize host’s sphingolipids for survival and proliferation. In this study, gene expression of serine palmitoyltransferase (SPT) subunit two (MmLCB2) of the mouse macrophage cell line (RAW264.7), which is the first enzyme in the de novo sphingolipid biosynthesis, was detected in both infected and non-infected macrophages. This was detected under condition where available sphingolipid was reduced, with the new world species Leishmania mexicana. Results of qPCR analysis showed that there was no differen

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Food Chemistry
Development of cellulose Nanofiber-based substrates for rapid detection of ferbam in kale by Surface-enhanced Raman spectroscopy
...Show More Authors

View Publication
Scopus (28)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Epicatechin product of Camellia sinensis leaves detection by thin layer chromatography and high performance liquid chromatography
...Show More Authors

The current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method). Qualitative and quantitative determinations of epicatechin in two tea samples were investigated. Epicatechin identification was made by utilizing preliminary chemical tests and TLC. This identification was also boosted by HPLC and then quantified epicatechin in all ethyl acetate fractions of two tea samples. This research revealed the existence of epica

... Show More
Scopus (2)
Scopus Crossref
Publication Date
Fri May 03 2024
Journal Name
Optical And Quantum Electronics
Design and analysis of a dual-core PCF biosensor based on SPR for cancerous cells detection
...Show More Authors

View Publication
Scopus (26)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Sat Nov 29 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Plasma Treatment on Shear Bond Strength of High Impact Acrylic Resin Denture Base Lined with Two Types of Soft Lining Materials after Immersion in Distilled Water and Denture Cleanser
...Show More Authors

Background: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Types of the Fiber Glass-Mat on Fatigue Characteristic of Composite Materials at Constant Fiber Volume Fraction: Experimental Determination
...Show More Authors

The aim of this work is to study the influence of the type of fiber glass –mat on fatigue behavior of composite material which is manufactured from polyester and E-glass (woven roving, chopped strand mat (CSM)) as a laminate with a constant fiber volume fraction (VF) of 33%. The results showed that the laminates reinforced with E-glass (woven roving) [0/90, ±45.0/90] and [0/90, CSM, 0/90] have lower fatigue strength than the laminates reinforced with E-glass [0/90]3,[CSM]3 and [CSM, 0/90, CSM]  although they had different tensile strength; the best laminate was [0/90]3 .

View Publication Preview PDF
Publication Date
Sat Nov 29 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of plasma treatment on shear bond strength of soft denture liner with two different types of denture base material (heat cure and light cure)
...Show More Authors

Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft

... Show More
View Publication Preview PDF