BACKGROUND: Hospital training courses for pharmacy students were required to prepare students to meet the challenges of real-world hospital work. AIM: Because there have been few studies on the efficacy of such courses, we aimed to recognize recent graduates’ perceptions, benefits, and factors influencing the quality of hospital training courses for pharmacy students. METHODS: A qualitative study using a phenomenology approach was conducted in 2022 and included several hospitals in Baghdad, Iraq, using in-depth face-to-face individual-based semi-structured interviews. Until saturation, a convenient sample of recently graduated pharmacists was included. The obtained data were analyzed using a thematic content analysis approach. RESULTS: A total of 40 recently graduated pharmacists participated in this study. Twenty-two participants took the hospital training course by direct attendance, while eighteen received the course online. A higher proportion of pharmacists stated that the hospital training course was beneficial and effective. The information obtained in the course is adequate in the direct attendance group, while those in the online group are inadequate. The teaching staff was the most influential factor influencing educational quality. The stress of studying during the training course hampered approximately 40% of the participants. CONCLUSION: The hospital training course effectively prepared the graduate pharmacist for future work in hospitals. On the other hand, the online training course was insufficient and only provided students with theoretical, repetitive information with no practical engagement. Still, there is a need to improve the course in terms of lengthening the course, reducing crowding, and expanding the role of the teaching staff.
In this study, a different design of passive air Solar Chimney(SC)was tested by installing it in the south wall of insulated test room in Baghdad city. The SC was designed from vertical and inclined parts connected serially together, the vertical SC (first part) has a single pass and Thermal Energy Storage Box Collector (TESB (refined paraffin wax as Phase Change Material(PCM)-Copper Foam Matrix(CFM))), while the inclined SC was designed in single pass, double passes and double pass with TESB (semi refined paraffin wax with copper foam matrix) with selective working angle ((30o, 45o and 60o). A computational model was employed and solved by Finite Volume Method (FVM) to simulate the air i
... Show MoreLinear motor offers several features in many applications that require linear motion. Nevertheless, the presence of cogging force can deteriorate the thrust of a permanent magnet linear motor. Using several methodologies, a design of synchronous single sided linear iron-core motor was proposed. According to exact formulas with surface-mounted magnets and concentrated winding specification, which are relying on geometrical parameters. Two-dimensional performance analysis of the designed model and its multi-objective optimization were accomplished as a method to reduce the motor cogging force using MAXWELL ANSYS. The optimum model design results showed that the maximum force ripple was approximatrly reduced by 81.24%compared to the origina
... Show MoreThis article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs
... Show MoreIn solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational
... Show MoreIn this work, the effect of variation of semi-angle of the conical part on the vibration characteristics of cylindrical-conical coupled structure is investigated. The shell is made of polyester resin reinforced by continuous E-glass fibers. The case is analyzed experimentally and numerically for orthotropic shell structures. The experimental program is conducted by exciting the fabricated structure by an impact hammer and monitoring the response using an attached accelerometer for different semi-angles of the conical part.
Software named SIGVIEW is used to perform the signal processing on the acquired signal in order to measure the natural frequencies and the corresponding mode shapes. The numerical investigation is achieved using ANS