Preferred Language
Articles
/
bsj-869
Calculations of Signal to Noise Ratio (SNR) for Free Space Optical Communication Systems
...Show More Authors

In this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
2015 9th Malaysian Software Engineering Conference (mysec)
Factors for communication technologies selection within virtual software teams
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Computers, Materials & Continua
An Optimal Algorithm for Resource Allocation in D2D Communication
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Accounting And Financial Sciences Journal
The Extent to which the Quality of Accounting Information Systems Contributes to Reducing Material
...Show More Authors

This research dealt with shedding light on the nature of material misrepresentations, in addition to knowing the extent to which the quality of accounting information systems contributes to reducing material misrepresentations On the theoretical side, a number of sources were relied upon in dealing with the research problem and presentation of the topic, while in the practical side, it was relied on the questionnaire form, where the research sample was (accountants and auditors), where 50 forms were distributed and 50 were received, and the data was analyzed and hypotheses tested through the program Statistical spss to show the relationship between the variables. The research reached a number of conclusions, the most important of which is t

... Show More
View Publication
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Classification of fetal abnormalities based on CTG signal
...Show More Authors

The fetal heart rate (FHR) signal processing based on Artificial Neural Networks (ANN),Fuzzy Logic (FL) and frequency domain Discrete Wavelet Transform(DWT) were analysis in order to perform automatic analysis using personal computers. Cardiotocography (CTG) is a primary biophysical method of fetal monitoring. The assessment of the printed CTG traces was based on the visual analysis of patterns that describing the variability of fetal heart rate signal. Fetal heart rate data of pregnant women with pregnancy between 38 and 40 weeks of gestation were studied. The first stage in the system was to convert the cardiotocograghy (CTG) tracing in to digital series so that the system can be analyzed ,while the second stage ,the FHR time series was t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 17 2013
Journal Name
Sensors
Evolution of Electroencephalogram Signal Analysis Techniques during Anesthesia
...Show More Authors

Biosignal analysis is one of the most important topics that researchers have tried to develop during the last century to understand numerous human diseases. Electroencephalograms (EEGs) are one of the techniques which provides an electrical representation of biosignals that reflect changes in the activity of the human brain. Monitoring the levels of anesthesia is a very important subject, which has been proposed to avoid both patient awareness caused by inadequate dosage of anesthetic drugs and excessive use of anesthesia during surgery. This article reviews the bases of these techniques and their development within the last decades and provides a synopsis of the relevant methodologies and algorithms that are used to analyze EEG sig

... Show More
View Publication
Scopus (52)
Crossref (52)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Compression of an ECG Signal Using Mixed Transforms
...Show More Authors

Electrocardiogram (ECG) is an important physiological signal for cardiac disease diagnosis. With the increasing use of modern electrocardiogram monitoring devices that generate vast amount of data requiring huge storage capacity. In order to decrease storage costs or make ECG signals suitable and ready for transmission through common communication channels, the ECG data
volume must be reduced. So an effective data compression method is required. This paper presents an efficient technique for the compression of ECG signals. In this technique, different transforms have been used to compress the ECG signals. At first, a 1-D ECG data was segmented and aligned to a 2-D data array, then 2-D mixed transform was implemented to compress the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 12 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Calculations of Gabor Lens Having Two Glaser Field Distributions
...Show More Authors

     The present computational work is focused on investigating some properties of Gabor lens. The Gabor lens under consideration consists of two fields, electrostatic and magnetic. The Glaser field model is assumed to represent each field along the optical axis. Under zero magnification condition the trajectory of charged particles along the axis of Gabor lens has been computed. The results have shown that a lens of short focal length and hence high refractive power can be achieved

View Publication Preview PDF
Publication Date
Thu Jun 15 2023
Journal Name
Bionatura
Copper-to-Zinc Ratio as an Inflammatory Marker in Serum of Iraqi Patients with Axial Spondyloarthritis
...Show More Authors

Axial spondyloarthritis (axSpA) is a chronic rheumatic inflammatory disease affecting mainly the spine and sacroiliac joints. Since the copper-to-zinc ratio (Cu/Zn) indicates an inflammatory response, the change in ratio is expected to correlate with axSpA. This study compared levels of Cu/Zn in the serum of axSpA patients. Serum samples were obtained from 53 patients with axSpA divided according to biological treatment into cohorts A and B, and 28 healthy control as cohort C. Serum levels of Cu and Zn were determined first by a fully automated chemistry analyzer TC-Matrix Plus, then the ratio was obtained. The elevated serum Cu concentration means of cohort B (189.32 ± 13.808 µg/dL) compared to cohort A (168.85 ± 7.244 µg/dL) a

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Value of random urinary calcium to creatinine ratio in diagnosing hypercalciuria in children with nocturnal enuresis
...Show More Authors

Background:Nocturnal Enuresis is a common problem affecting 20% of five years old children and up to 2% of adolescent and young adult. Although it is a self limiting benign condition, it has social and psychological impact on the child and his family. Many pathophysiological theories had been suggested, but none is confirmed. Hypercalciuria has been suggested to be associated with higher incidence of nocturnal enuresis. Objectives:The aim of our study to test the value of Ca/Cr ratio, on random urine sample, in diagnosing hypercalciuria in enuretic children. Type of study: Cross sectional study.Methods:Forty four enuretic children were enrolled in this study and forty five children without nocturnal enuresis were taken as control group.

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees19gr
Theoretical calculations involving a standard neutron yield distribution for the T-T nuclear fusion reaction
...Show More Authors

A standard theoretical neutron energy flux distribution is achieved for the triton-triton nuclear fusion reaction in the range of triton energy about ≤10 MeV. This distribution give raises an evidence to provide the global calculations including the characteristics fusion parameters governing the T-T fusion reaction.

View Publication Preview PDF
Scopus Clarivate Crossref