The purpose of this study was to measure serum levels of insulin-like growth factor-binding protein (IGFBP7), Insulin-like Growth Factor 1 (IGF-1), Growth Hormone (GH), Interleukin 6 (IL-6) and insulin in acromegaly patients and healthy controls. The acromegaly group had 60 patients, while the population group had 30 people who had never had acromegaly before. The concentration of IGFBP7, IGF-1, GH, IL-6, and insulin were determined. The results of the present study indicate that IGFBP7 level in the acromegaly group was significantly lower (1.690.07 ng/mL vs. 2.740.12 ng/mL, respectively, p = 0.001). IGF-1, GH, IL-6, and insulin concentrations were also significantly higher in acromegaly patients. The diagnostic accuracy (2.194) was excellent in separating acromegaly from the healthy patient group, and the area under the curve (AUC = 0.871, p = 0.001). From the results of the present study, we can conclude that serum IGFBP7 can be used to distinguish acromegaly patients from healthy individuals.
The aim of this research is to know the effect of two strategies of active learning, the five fingers and traffic signals, on the first grade intermediate level student's achievement and personal intelligence. The research sample was chosen from the Al- Mansour intermediate school for boys, including (101) students divided into three groups chosen randomly which represented the first experimental group (32) students, the second experimental group (34) students, and the control group (33) students. To achieve the research aims, the research prepared a physics achievement test containing (26) items, and a personal intelligence test containing (20) items. The psychometric characteristics, of the tests were checked up the following results were
... Show MoreThe new ligand [N1,N4-bis((1H-benzo[d]Glyoxalin-2-yl)carbamothioyl)Butanedi amide] (NCB) derived from Butanedioyl diisothiocyanate with 2-aminobenz imidazole was used to prepare a chain of new metal complexes of Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Pd(II), Ag(I), Cd(II) by general formula [M(NCB)]Xn ,Where M= Cr(III), n=3, X=Cl; Mn(II), Co(II), Ni(II), Cu(II), Pd(II), Cd(II) ,n=2 , X=Cl; Ag(I), n=1, X=NO3. Characterized compounds on the basis of 1H, 13CNMR (for (NCB), FT-IR and U.V spectrum, melting point, molar conduct, %C, %H, %N and %S, the percentage of the metal in complexes %M, Magnetic susceptibility, thermal studies (TGA),while its corrosion inhibition for mild steel in Ca(OH)2 solution is studied by weight loss. These measureme
... Show MoreThe percentage of fatty acids, quantity of tocopherols, tocotrienols, carotens and physiochemical characteristics of crude red palm oil have been evaluated, in addition to specific chemical detection of active compounds unsaponifiable matters. Results of Gas Liquid Chromatography showed:- The major fatty acids in red palm oil is palmitic (44.36%) then oleic (39.65%), linolenic (10.55%), stearic (3.56%), myristic (1.22%), arachdonic (0.24%) and palmotic (0.19%). Red palm oil contains ? – ?- ?- ? – Tocopherols with concentration 258 , 121 , 259, 109 m/kg oil , ? – ?- ?- ? – Tocotrienol with concentration 462.77 , 571.03, 619.18, 509.07 m/kg oil respectively. Total tocopherols & tocotrienols 2909.05 m/kg oil and
... Show MoreIn this study, polymeric coating was developed by incorporating nano graphene in the polymer blend with applications to oil storage tanks. The oil storage tanks samples were brought from the oil Pipeline Company / Doura refinery in Baghdad. The coating polymer was formed with a blend (epoxy resin and repcoat ZR). The proportion of mixing the mixture was 3:1:1 epoxy resin 21.06 gm: repcoat ZR 10.53 gm: hardener 10.53 gm. The blend/graphene was prepared using in stui-polymerization method with different weight percentage 1, 3, 5, and 7 wt % added to blend. The resulting solution was put in a glass tube on a magnetic stirrer for one hour at a temperature of 40 °C. The result of contact angle and water absorption the best ratio of 3wt
... Show MoreEstimation of the unknown parameters in 2-D sinusoidal signal model can be considered as important and difficult problem. Due to the difficulty to find estimate of all the parameters of this type of models at the same time, we propose sequential non-liner least squares method and sequential robust M method after their development through the use of sequential approach in the estimate suggested by Prasad et al to estimate unknown frequencies and amplitudes for the 2-D sinusoidal compounds but depending on Downhill Simplex Algorithm in solving non-linear equations for the purpose of obtaining non-linear parameters estimation which represents frequencies and then use of least squares formula to estimate
... Show MoreDue to its various resistance mechanisms, Pseudomonas aeruginosa is the most prevalent opportunistic infection that kills hospitalized patients. Thus, therapeutic options become limited. Objective: The study aimed to estimate the antibiofilm effectiveness of Conocarpus erectus leaf extracts against MDR P. aeruginosa isolates and examines pelA and algD gene expression. Subjects and Methods: One hundred-fifty clinical samples were collected from five Baghdad hospitals between September 2021 and January 2022. Samples were grown on different mediums. Despite cetrimide agar's ability to detect P. aeruginosa, only 83 isolates developed at 42°C. VITEK 2 compact system identification followed. This study examined 83 of P. aeruginosa isolates for r
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli