In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having higher values of µ/ρ, show minimum dose rate values. (µ/ρ) and RPE% values were enhanced, the concrete containing E/Mag/B4C (S2) had the best results, while the concrete containing Ep (S4) provide the worst results. The ANN prediction results take 15 sec for estimating gamma doses corresponding to seventeen shield thicknesses, while the theoretical MCNP-5 results took approximately between 7 to 10 hours for five gamma doses. ANN provides excellent predictions with a high degree of correlation depending on increasing the number of attenuation parameters used in the training process. Also, it predicts gamma dose rates for a large number of shield thicknesses that cannot be calculated theoretically in a very short time. This supports, the created epoxy composite offers good attenuation properties for many shielding applications and could be proposed as an injecting mortar for cracks in biological shields and the walls of diagnostic and radiotherapy rooms. However, further investigations are planned for different filler ratios, for comparison purposes, in order to reach optimal shielding properties
MR Younus…, 2020 - Cited by 2
The present study aimed to evaluate the levels of total immunoglobulin E and percentage count of eosinophil in some of allergic disease. Blood sample collected from 210 patients (110 female, 100 male) with allergic disease (allergic asthma, allergic rhinitis, and urticaria) their age between 10-70 years and 50 healthy control their age between 23-52 years. A highly significant (P<0.01) increase in the mean serum total IgE in patients with asthma (503.54 ± 63.49 IU/ml), Allergic rhinitis (442.77 ± 95.76 IU/ml) and urticaria (489.53 ± 69.68 IU/ml) as a compared with healthy controls (23.67 ± 5.81 IU/ml).There was a significant difference in percentage count of eosinophil in patients groups allergic asthma 4.37 ± 0.52% ,allergic rhinitis
... Show MoreA new series of morpholine derivative were prepared by reacting the morpholine with ethyl chloro acetate in the presence triethylamine as an catalyst and benzene as a solvent gave the ethyl morpholin-4-ylacetate reaction with hydrazine hydrate and ethanol as a solvent gave the 2-(morpholin-4-yl)acetohydrazide gave series of Schiff base were prepared by reacting 2-(morpholin-4- yl)acetohydrazide with different aromatic aldehydes and ketons . The new series of (3-9 )were synthesis by reaction of Schiff base (10-14) with chloroacetyl chloride, triethyl amine as an catalyst and 1,4dioxane as a solvent .The chemical structures of the synthesis compound were identified by spectral methods their [ IR ,1H-NMR and 13C-NMR ].The synthesised compoun
... Show MoreThe present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.
Abstract :- In this paper, silver nanoparticles had been prepared by chemical reduction method. Many tests had been done to it such as UV-Visible spectrophotometer, XRD, AFM&SEM test. finally an attempt had been done to get the optimum condition to control the grain size of silver Nanoparticles by variation the heating period and other parameters which has an effect in silver Nanoparticles synthesis process. in this method we can get a silver nanoparticles in the size range from 52 to 97 nm.
In this study, the relationship between the bare soil temperature with respect to its salinity is presented, the bare soil feature is considered only by eliminating all other land features by classifying the site location by using the support vector machine algorithm, in the same time the salinity index that calculated from the spectral response from the satellite bands is calibrated using empirical salinity value calculated from field soil samples. A 2D probability density function is used to analyze the relationship between the temperature rising from the minimum temperature (from the sunrise time) due to the solar radiation duration tell the time of the satellite capturing the scene image and the calibrated salinity index is presented. T
... Show MoreShiranish formation has been divided into two microfacies units: 1-Marly biowacke stone facies 2-Biogenic pack stone facies These microfacies reflected marine deep shelf margin in the upper part of the formation, the lower part was deeper. 238 slides were investigated depending on Mineralogical, compositional and Biological processes, which reflect deep shelf margin at upper part of the formation, but at the lower part open sea environment. The age of the formation is estimated depending on the recognized biostratigraphic zone using the index fossils to be Upper- Middle Maestrichtian.
Background: Fiber-optic endoscopy is an important
investigation of the large intestine, whether or not the
radiologist (barium enema) has discovered a lesion in
the bowel. Colonoscopy affords a unique opportunity
to direct visualization of entire colonic mucosa. At
the same time, the physician can obtain biopsy specimens, remove polyps, and decompress volvuli.
Most experienced endoscopists and well prepared
patients can reach the cecum in over 90% of patients.
If colonoscopy is properly performed, it has a low
risk of complications, such as perforation and bleeding.
Methods: A total of 70 consecutive patients admitted
to Endoscopy department at Al-Kindy Teaching hospital from September- 2008 to July-2009.
KE Sharquie, GA Ibrahim, AA Noaimi, HK Hamudy, J Saudi Soc Dermatol Dermatol Surg, 2010 - Cited by 2