Preferred Language
Articles
/
bsj-7685
Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
...Show More Authors

In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having higher values of µ/ρ, show minimum dose rate values. (µ/ρ) and RPE% values were enhanced, the concrete containing E/Mag/B4C (S2) had the best results, while the concrete containing Ep (S4) provide the worst results. The ANN prediction results take 15 sec for estimating gamma doses corresponding to seventeen shield thicknesses, while the theoretical MCNP-5 results took approximately between 7 to 10 hours for five gamma doses. ANN provides excellent predictions with a high degree of correlation depending on increasing the number of attenuation parameters used in the training process. Also, it predicts gamma dose rates for a large number of shield thicknesses that cannot be calculated theoretically in a very short time. This supports, the created epoxy composite offers good attenuation properties for many shielding applications and could be proposed as an injecting mortar for cracks in biological shields and the walls of diagnostic and radiotherapy rooms. However, further investigations are planned for different filler ratios, for comparison purposes, in order to reach optimal shielding properties

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun May 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Calculation and Study of Gamma ray Attenuation Coefficients for Different Composites
...Show More Authors

In this work, the total linear attenuation coefficients µ(cm
-1
) were calculated and studied
for particulate reinforced polymer-based composites. Unsaturated polyester (UP) resin was
used as a matrix filled with different concentrations of Al, Fe, and Pb metal powders as
reinforcements. The effect of the metal powders addition at different weight percentages in
the range of (10,20,30,40,50)wt % and gamma energy on attenuation coefficients was studied.
The results show, as the metallic particulates content increase, the attenuation coefficients will
increase too, while it, were exhibited a decrease in their values when the gamma energy
increase.The total linear attenuation coefficients of gamma ray fo

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Study the Shielding Properties against Gamma-rays for Epoxy Resin Reinforced by Different materials
...Show More Authors

In the present work the Buildup factor for gamma rays were studied in shields from epoxy reinforced by lead powder and by aluminum powder, for NaI(Tl) scintillation detector size ( ×? ), using two radioactive sources (Co-60 and Cs-137). The shields which are used (epoxy reinforced by lead powder with concentration (10-60)% and epoxy reinforced by aluminum powder with concentration (10-50)% by thick (6mm) and epoxy reinforced by lead powder with concentration (50%) with thick (2,4,6,8,10)mm. The experimental results show that: The linear absorption factor and Buildup factor increase with increase the concentration for the powders which used in reinforcement and high for aluminum powder than the lead powder and decrease with inc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
Gamma-Ray Shielding Effectiveness of Clay and Boron Doped Clay Material at Different Thicknesses
...Show More Authors

      In this work, the gamma-ray shielding parameters of red clay and boron-doped red clay with different sample thicknesses are theoretically and experimentally reported. These shielding parameters are considered at a photon energy of 0.662 MeV emitted from 137Cs. The theoretical calculations are demonstrated using the XCom software program, while a scintillation detector, NaI(TI), with an efficiency of 98% is used to attain the experimental results of the mass attenuation coefficient of the prepared samples. The acquired results show that the boron-doped clay delivers a higher mass attenuation coefficient as compared to those of pure clay. Additionally, the mass attenuation coefficient exhibits an increasing behavior w

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Apr 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Gamma Ray Attenuation Coefficients for Lead Oxide and Iron Oxide Reinforced In Silicate Glasses as Radiation Shielding Windows
...Show More Authors

     In this work, the mass attenuation coefficient, effective atomic number and half value layer parameters were calculated for silicate (SiO2) mixed with various levels of lead oxide and iron oxide as reinforced materials. SiO2 was used with different concentrations of PbO and Fe2O3 (25, 50 and 75 weight %). The glass system was prepared by the melt-quenching method. The attenuation parameters were calculated at photon energies varying from 1keV to 100MeV using the XCOM program (version 3.1). In addition, the mass attenuation coefficient and half value layer parameters for selected glass samples were experimentally determined at photon energies 0.662 and 1.28 MeV emitted from radioactive sources 137Cs and 22Na respe

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 03 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparative study of two different techniques for leak and bleeding prevention during laparoscopic sleeve gastrectomy
...Show More Authors

Background: Laparoscopic sleeve gastrectomy has gained more popularity as an independent bariatric procedure because laparoscopic sleeve gastrectomy was reported to be an effective, safe, and time-savingprocedure, leading to adequate weight loss for morbidly obese patients and becoming one of the most common procedures performed for the treatment of morbidly obese patients in the last few years until now.
Objectives: The aim of this study is to compare two different techniques of the reinforcement of staple line during LSG in the reduction of major complications (bleeding and leak).
Patients and methods: prospective randomized study of a consecutive series of 126 patients that underwent LSG between April 20

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Experimental study of some shielding parameters for composite shields
...Show More Authors

View Publication
Scopus (8)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Study of target volume effect on efficiency index and paddick comformty index for arteriovenous malformation treatment plans by gamma knife : Study of target volume effect on efficiency index and paddick comformty index for arteriovenous malformation treatment plans by gamma knife
...Show More Authors

الهدف نظرًا   لأن الطاقة هي نتاج الحجم مرات الجرعة ، يتم إعطاء الأحجام ترجيحًا يتناسب مع الجرعة التي تلقتها. هذه نتيجة أن الطاقة هي مقياس لمقدار المادة التي تم امتصاصها. مؤشر الكفاءة عبارة عن إحصائية واحدة يمكن استخدامها لتقييم جودة الخطة بكفاءة من خلال م

... Show More
View Publication
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Structure dependence of gamma ray irradiation effects on polyurethane and epoxy resin studied by PAL technique
...Show More Authors

Positron annihilation lifetime (PAL) technique has been employed to
study the microstructural changes of polyurethane (PU), EUXIT 101
and epoxy risen (EP), EUXIT 60 by Gamma-ray irradiation with the
dose range (95.76 - 957.6) kGy. The size of the free volume hole and
their fraction in PU and EP were determined from ortho-positronium
lifetime component and its intensity in the measured lifetime spectra.
The results show that the irradiation causes significant changes in the
free volume hole size (Vh) and the fractional free volume (Fh), and
thereby the microstructure of PU and EP. The results indicate that
the γ-dose increases the crystallinity in the amorphous regions of PU
and increas

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study Reinforcing and Applied Load of Wear Rate for Epoxy Composites
...Show More Authors

This research studies Reinforcing and applied load of  Wear Rate for Epoxy composites contains from epoxy resin (Ep) as a matrix material and reinforced by Gawain red wood flour , Russian white wood flour , glass powder and rock wool fibers , with volume fraction (20%) for all samples in lab conditions.  by using the load (10,20 ,30 ,40) Newton of iron disc for testing  time(10) minute, and the results have shown that the reinforcing of epoxy resin led to decrease  wear rate for all samples except the hybrid composites reinforced earth glass powder , that the wear rate values  decrease  from   (22×10-9g/cm) to (4×10-9g/cm) of composite material(Ep+R.W.F) and thus(Ep+W.W.F)   at la

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 24 2021
Journal Name
Iraqi Journal Of Science
Study of Thermal Conductivity and Solution Absorption for Epoxy –Talc Composites
...Show More Authors

In this research prepared Epoxy – Talc powder composites with weight ratio of Talc powder (0,5,10,15,20,25)% . The value of thermal conductivity increase with increasing ratio of talc powder and water absorption increase with increasing ratio of talc powder because the structure from magnesium silicate hydroxide and hydrophilic nature .Ethanol absorption decrease with increasing percentage talc powder compared with epoxy pure

View Publication Preview PDF
Crossref (1)
Crossref