Preferred Language
Articles
/
bsj-7253
Determination of essential and trace elements in various vegetables using ICP-MS
...Show More Authors

Metal contents in vegetables are interesting because of issues related to food safety and ‎potential health risks. The availability of these metals in the human body ‎may perform many biochemical functions and some of them linked with various diseases at ‎high levels. The current study aimed to evaluate the concentration of various metals in ‎common local consumed vegetables using ICP-MS. The concentrations of metals in vegetables ‎of tarragon, Bay laurel, dill, Syrian mesquite, vine leaves, thymes, arugula, basil, common ‎purslane and parsley of this study were found to be in the range of, 76-778 for Al, 10-333 for B, 4-119 for ‎Ba, ‎2812‎-24645 for Ca, 0.1-0.32 for Co, 201-464 for Fe, 3661-46400 for K, 0.31–‎‎1.53 for Li, 860-14330 for Mg, 16.20-71.5 for Mn, 612-4725 for Na and 15.8-46 µg ‎g-1 for Zn. The results revealed that the concentration of Al, B except in Syrian mesquite, Ba, Ca, ‎Fe, K, Mg and Mn in all analysed vegetables is higher than the recommended value, Li is ‎well-within the safe limit, and Co, Na except in dill, arugula and common purslane, Zn are ‎lower than the recommended intake of these elements. From health point of view, the HQ values for Al, Fe ‎‎(for all vegetables) and Ba (in dill, vine leaves, thymes, arugula, basil, common ‎‎purslane and ‎parsley) were higher than one, indicating potential non-cancer health risk due to exposure to ‎these metals. Furthermore, the HI value for all vegetables was higher than one, indicating ‎potential non-cancer health risk due to long-term exposure to these metals.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2008
Journal Name
Journal Of Al-nahrain University
DETERMINATION THE AGE OF GALAXIES USING STRONG GRAVITATIONAL LENSING
...Show More Authors

Most of the known cases of strong gravitational lensing involve multiple imaging of an active galactic nucleus. The properties of lensed active galactic nuclei make them promising systems for astrophysical applications of gravitational lensing. So we present a simple model for strong lensing in the gravitational lensed systems to calculate the age of four lensed galaxies, in the present work we take the freedman models with (k curvature index =0) Euclidian case, and the result show a good agreement with the other models.

Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Physics
Evaluate the Distribution of Heavy Elements that Dissolved in Ground Water Using IDW in AL-Wafa City, Al-Ramadi,Iraq
...Show More Authors

Groundwater can be assessed by studying water wells. This study was conducted in Al-Wafa District, Anbar Governorate, Iraq. The water samples were collected from 24 different wells in the study area, in January 2021. A laboratory examination of the samples was conducted. Geographical information systems technique was relied on to determine the values of polluting elements in the wells. The chemical elements that were measured were [cadmium, lead, cobalt and chromium]. The output of this research were planned to be spatial maps that show the distribution of the elements with respect to their concentrations. The results show a variation in the heavy elements concentrations at the studied area groundwater. The samples show different values

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Lecture Notes In Electrical Engineering
A Study of the Influence of Steel Brushes in Rail Surface Magnetic Flux Leakage Detection Using Finite Elements Simulation
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Procaine HCl in Pharmaceutical Preparations Via Using Diazotization and Coupling Reaction
...Show More Authors

Simple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. A

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 02 2026
Journal Name
دار الكوثر للطباعة
طيف التوحد: دليلي أكاديمي التشخص والفهم النفسي والتربوي
...Show More Authors

Publication Date
Sat Dec 09 2023
Journal Name
Acta Geochimica
Provenance and depositional setting of the Late Miocene- Pleistocene clastic sediments in the eastern Arabian Peninsula and western Iraq using rare earth elements geochemistry
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Apr 03 2023
Journal Name
Journal Of Educational And Psychological Researches
The Effectiveness of Using Cubing Technique in the Iraqi EFL Secondary Students' Composition Writing, Vocabulary, and Meta-Cognitive Awareness
...Show More Authors

Abstract

The aim of this research is to determine how well the Cubing Technique affects the Iraqi EFL students' composition writing, vocabulary, and meta-cognitive awareness of writing strategies. The sample of (64) secondary-school female students in the fifth grade is drawn from two classrooms and split into two equal groups: the experimental group and the control group, each of which consists of (32) students. A quasi-experimental design is applied. The performance test and Meta-cognitive Writing Strategies questionnaire are given as a pre-test for equalizing the two groups after ensuring their validity and reliability. Then, they are administrated as a posttest in both groups. According to the results, the si

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Automatic Determination of Liquid's Interface in Crude Oil Tank using Capacitive Sensing Techniques
...Show More Authors

The petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 26 2022
Journal Name
Iraqi Journal Of Science
Potentiometric Determination of Mebeverine Hydrochloride Using Imprinted Molecular Polymer in PVC Matrix Membrane‏
...Show More Authors

Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (4)
Crossref