The pancreatic ductal adenocarcinoma (PDAC), which represents over 90% of pancreatic cancer cases,
has the highest proliferative and metastatic rate in comparison to other pancreatic cancer compartments. This
study is designed to determine whether small nucleolar RNA, H/ACA box 64 (snoRNA64) is associated with
pancreatic cancer initiation and progression. Gene expression data from the Gene Expression Omnibus (GEO)
repository have shown that snoRNA64 expression is reduced in primary and metastatic pancreatic cancer as
compared to normal tissues based on statistical analysis of the in Silico analysis. Using qPCR techniques,
pancreatic cancer cell lines include PK-1, PK-8, PK-4, and Mia PaCa-2 with different levels of snoRNA64,
including PK-1, PK-8, PK-4, and Mia PaCa-2. The level of expression is correlated with the cell line epithelial
or mesenchymal characteristics. Cell lines displaying epithelial characteristics such as PK-1, PK-8 show high
levels of snoRNA64 meanwhile, cell lines displaying mesenchymal characteristics such as PK-4, Mia PaCa-2
show low levels of snoRNA64. The level of expression is correlated with the cell line epithelial or
mesenchymal characteristics. After knocking down the PK-8 with high snoRNA64 expression, the epithelial
markers E. cadherin (E-cad) and Cytokeratin-8 (CK-8) are decreased, while mesenchymal markers Vimentin
(Vim), Cytokeratin-19 (CK-19), Metalloprotease -2 (MMP-2), and Metalloprotease-3 (MMP-3) are activated.
Those changes suggest that PK-8 responding to the snoRNA64 knock down protocol and increase in
mesenchymal function. Together, snoRNA64 expression may participate in epithelial to mesenchymal
transition (EMT) and mesenchymal to epithelial transition (MET), in which during metastasis these processes
are crucial. In addition, snoRNA64 may be considered as a potential diagnostic biomarker for both early and
invasive stages of PDAC. And due to its gradual expression decreases, it may be considered a barrier in tumor
progression.
Fire is one of the most critical risks devastating to human life and property. Therefore, humans make different efforts to deal with fire hazards. Many techniques have been developed to assess fire safety risks. One of these methods is to predict the outbreak of a fire in buildings, and although it is hard to predict when a fire will start, it is critical to do so to safeguard human life and property. This research deals with evaluating the safety risks of the existing building in the city of Samawah/Iraq and determining the appropriateness of these buildings in terms of safety from fire hazards. Twelve parameters are certified based on the National Fire Protection Association (NFPA20
The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed
... Show MoreThe psychological burnout is considered one of dangerous phenomenon’s which appeared in the 70s of the 20th century and suffered by most of the society classes. It is a term which the wide uses and various meaning like emotional, mental, and physical exhaustion and chronic weak exhaustion. The presented research aims t identify the psychological burnout as for the Kindergarten teacher and the differences significance according to the variations (Kindergarten type: private or govern mental). The research sample contains 400 female teachers divided to 170 governmental Kindergarten teachers and 230 private Kindergarten teachers. The researcher prepared a measurement method to measure the psychological burnout for those teachers after
... Show MoreThe heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed
... Show MoreIn high-dimensional semiparametric regression, balancing accuracy and interpretability often requires combining dimension reduction with variable selection. This study intro- duces two novel methods for dimension reduction in additive partial linear models: (i) minimum average variance estimation (MAVE) combined with the adaptive least abso- lute shrinkage and selection operator (MAVE-ALASSO) and (ii) MAVE with smoothly clipped absolute deviation (MAVE-SCAD). These methods leverage the flexibility of MAVE for sufficient dimension reduction while incorporating adaptive penalties to en- sure sparse and interpretable models. The performance of both methods is evaluated through simulations using the mean squared error and variable selection cri
... Show MoreThe main objective of the present work is to find a method increases the efficiency of the airfoil that is used for blade in wind turbine, wing in aircraft, propeller and helicopter (like NACA 4412). By overcoming the separation of flow at high angle of attacks, a slotted airfoil had been used and solved numerically through connecting the pressure side in the bottom surface with the suction side in the top surface of the airfoil to energize the separated flow. Slot exit, width and slope were considered as a parameters of slot configuration to determine the effective design of consideration. Reynolds number was taken as [1.6 x106 ] and the angle of attacks were ranged from (0o - 20o ). The numerical solution with Ansys Fluent commercial prog
... Show More