The human kidney is one of the most important organs in the human body; it performs many functions
and has a great impact on the work of the rest of the organs. Among the most important possible treatments is
dialysis, which works as an external artificial kidney, and several studies have worked to enhance the
mechanism of dialysate flow and improve the permeability of its membrane. This study introduces a new
numerical model based on previous research discussing the variations in the concentrations of sodium,
potassium, and urea in the extracellular area in the blood during hemodialysis. We simulated the differential
equations related to mass transfer diffusion and we developed the model in MATLAB Simulink environment.
A value of 700 was appeared to be the most appropriate as a mass transfer coefficient leading to the best
permeability. The suggested models enabled to track the temporal variations of urine, K and Na concentrations
in blood streamline. This also produced the time needed to reach the requested concentrations mentioned in
literature studies (960 ms). Concentrations evaluation was performed with error rates not exceeding 2% for all
ions compared to the normal values of human blood.The current work presents the first step towards combinig
the mass transfer and diffusion principles with our efforts in designing and implementing an electrophoresisbased implantable kidney.
This study estimated seven heavy metals (Fe, Cu, Zn, Pb, Ni, Cd, Cr) in water (dissolved and particulate phase), sediments and some aquatic organisms including two species from aquatic plants (Ceratophyllum demersum&Phragmites australis); one species of clam (Psedontopeses euphratics) and two species from fish (Oreochromis aureus& Leuciscus vorax)in four sites within Mashroo AL- Musayyib channel project/ branch of Euphrates river, Babylon , medial of Iraq . This aims to show the concentration of these elements, their fate and the mechanisms of their transmission through the food chain in this lotic aquatic system ; also in addition to examining some physicochemical properties of ri
... Show MoreBackground: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f
... Show MoreBackground: This study aimed to determine the value of Beta angle for a sample of Iraqi adults with class I skeletal and dental relations and to verify the existence of sexual dimorphism and to find out the relation between this angle and other craniofacial measurements. Materials and Methods: Sixty dental students (23 males and 37 females) with an age ranged between 20-31 years old and having class I skeletal and dental relations were chosen for this study. Each student was subjected to clinical examination and digital true lateral cephalometric radiograph. The radiographs were analyzed using AutoCAD 2007 computer program to measure the angular and linear variables. Descriptive statistics were obtained for the measurements for both genders
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli
Mn2O3 was coated onto reduced titania nanotubes by reverse pulse electrodeposition, showing smooth and homogenous deposits without covering the opening of the nanotubes.
To prepare a new ligand, many compounds were used to synthesize Schiff-Mannich base, such as isatin, Para chloro Aniline, 2-mercaptobenzimidazole and indole. The resulting compound 1-((2-((1H-indol-1-ylthio)-1H-benzo[d]imidazol1-yl)methyl)-3-(4-chlorophenylimino)indolin-2-one (L). (L) was used to create a series of metal ion complexes with Co (II), Ni (II), Cu (II), Pd (II), Pt (IV), and Au (III). C.H.N.S., FTIR, mass spectra UV-ViS, 1H-NMR, 13CNMR, magnetic moment, and molar conductivity were used to characterize all of these compounds. Except for the palladium(II) and gold(III) complexes, all of the produced complexes had an octahedral geometry, according to the data. The antibacterial activity of the produced compounds was tested by usin
... Show MoreIn this study, from a total of 856 mastitis cases in lactating ewes, only 34 Streptococcus agalactiae isolates showed various types of resistance to three types of antibiotics (Penicillin, Erythromycin and Tetracycline). St. agalactiae isolates were identified according to the standard methods, including a new suggested technique called specific Chromogenic agar. It was found that antibiotic bacterial resistance was clearly identified by using MIC-microplate assay (dilution method). Also, by real-time PCR technique, it was determined that there were three antibiotics genes resistance ( pbp2b, tetO and mefA ). The high percentage of isolate carried of a single gene which was the Tetracycline (20.59%) followed by percentage Penicillin was
... Show MoreObjective: This study aimed to evaluate the effectiveness of the Benson Relaxation Technique (BRT) in reducing pain during femoral artery sheath removal after percutaneous coronary intervention (PCI). Methods and Materials: A randomized controlled trial was conducted at three cardiac centers in Iraq. A total of 58 patients undergoing therapeutic PCI were randomly assigned into two groups: intervention (n=27) and control (n=31). The intervention group received BRT for 10 minutes before and after sheath removal. Pain was assessed using the Visual Analogue Scale (VAS) immediately after the procedure. Demographic data and clinical variables were collected. Data were analyzed using SPSS v26 and non-parametric tests (Mann-Whitney U, Krus
... Show More