Development of a precise and delicate reaction has been acquired for the determination of vancomycin hydrochloride using batch and cloud point extraction (CPE) methods. The first method is based on the formation of azo dye as a result of diazotized dapsone coupled with vancomycin HCl (VAN) in a basic medium. The sensitivity of this reaction was enhanced by utilizing a nonionic surfactant (Triton X-114) and the cloud point extraction technique (second method). The azo dye formed was extracted into the surfactant-rich phase, dissolved in ethanol and detected at λmax 440 nm spectrophotometrically. The reaction was investigated using both batch and CPE methods (with and without extraction), and a simple comparison between the two developed methods was made. The conditions that affect the extraction process and the sensitivity of the methods have been carefully examined. The linearity of the calibration curves was in the range of 3-50 and 0.5- 25 µg.mL-1 with limits of detection of 0.806 and 0.462 µg.mL-1 for VAN in both batch and CPE procedures, respectively. The percentage of relative standard deviation (R.S.D.%) for the two methods was better than 2.54% and 2.83%, respectively. The recommended procedures have been effectively used to assay VAN in commercial injections.
New, simple and accurate batch and flow injection spectrophotometric
methods have been developed for the determinationsof tetracycline
hydrochloride (TCH) and doxycycline hyclate (DCH) in pharmaceutical
preparations. The methods are based on diazotization of
metchlopramide and coupling reaction with either TCH or DCH in alkaline
medium to form yellow–orange water soluble dye with absorption maxima
at 414 and 436 nm for TCH and DCH, respectively. A graphs of absorbance
versus concentration show that Beer’s law was obeyed over the
concentration ranges of 1 –52 μgmL-1 TCH and DCH for batch method and
of 8 – 240 μg mL-1 TCH and 5 – 350 μgmL-1 DCH for FIA method. The
limits of detection in batchmetho
In current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show MoreAn accurate and sensitive spectrophotometric method has been developed for the determination of cefotaxime (CEF) in pure and pharmaceutical samples. The suggested method depended on the coupling reaction between diazotized cefotaxime and 3,5-dimethyl phenol (3,5-DMPH) in basic medium to form light orange, water soluble dye, that is stable and has a maximum absorbance at 497nm. The calibration graph was liner over the concentration range (1-70) µg.mL-1 with LOD of 0.750 µg.mL-1 and LOQ of. 2.740 µg. mL-1, sandal sensitivity of 0.0526 µg. cm-2 . molar absorptivity 11328 Lmol-1 cm-1 . The stoichiometry composition was found by Jobs a
... Show MoreA simple, fast and sensitive spectrophotometric method has been applied for the determination of tetracycline hydrochloride in its pure form and in pharmaceutical preparations. The method based on coupling reaction of the antibiotic with diazotized anthranilic acid to form a stable yellow azo dye which shows a maximum absorption at 419 nm. Uni- and multivariate approaches were followed in optimizing the experimental conditions. Under optimum experimental conditions obtained via multivariate (Central Composite Design), the linearity of the constructed calibration curve was in the range of 0.560 μg.mL-1 with molar absorptivity of 14619 L.mol-1.cm-1 and the value of detection limit was 0.2813μg.mL-1. The capability of the metho
... Show MoreThis work was influenced the separation and preconcentration steps were carried out to determination of metformin (MET) in pharmaceutical preparations and human serum samples. Complex formation method and cloud-point extraction (CPE) coupling with UV-Visible spectrophotometry were used to investigated of study target.The results has showed the best optical characteristic for calibration curve and statistical data which were obtained under optimum conditions. The first method is based on the reaction of MET with nickel (II) in alkaline medium an absorption maximum ?)max) at 434nm. ''Beer's low'' is obeyed in the concentration range (10-100µg.ml-1) with molar absorptivity of 3.9x103 L.mol-1.cm-1.The limit of detection and quantitation valu
... Show MoreSimple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. A
... Show MoreA simple, accurate and sensitive spectrophotometric way is used to determine Bisacodyl in pure and pharmaceutical preparations. The proposed method depends on using 2,4-Dinitrophenylhydrazine as chromogenic reagent . The method was based on the oxidative coupling reaction of Bisacodyl with 2,4-Dinitrophenylhydrazine with Sodium periodate in the presence of sodium hydroxide as alkaline media to form red water soluble dye product , that has a maximum absorption at ?max 522nm . Beer ,s law is obeyed in the concentration of (2.00–20.00) ?g.ml -1 .The molar absorptivity is (6505) L.mol-1.cm-1,a sandall sensitivity of(0.0555) ?g.cm-2), correlation coefficient of (0.9970) , Limitof detection (LOD) (0.0312 ?g.ml-1), limit of Quantitation (LOQ) (
... Show MoreA spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and l
... Show MoreA spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples
... Show MoreA simple, fast, and sensitive batch and flow injection spectrophotometric
methods have been developed for the determination of clonazepam(CZP) in pure
form and in pharmaceutical preparations. The proposed methods are based on the
oxidative coupling reaction of the reduced clonazepam using Zn powders and conc.
HCl with payrocatechol and in the presence of ferric sulphate. The resulting reddish
colored product had a maximum absorbance at 515 nm. The optimum reaction
conditions and other analytical parameters have been evaluated . The linear ranges
for the batch and FI methods determination of CZP were 0.5-32, 50-400 μg mL-1
and the detection limits were 0.193, 22.60 μg mL-1 for both methods respectively.
Statis