This study assessed the quality of hand-dug drinking water sources in Eku and its environs at Eku I, Samagidi, Eku 2, and Okuechi, using the weighted arithmetic water quality index method. Water samples collected from hand-dug wells at these locations returned values for analyzed parameters. Temperature 26 – 30(⁰C), dissolved Oxygen (D.O) 5.2-8mg/l, biological oxygen demand (BOD) 5.2-8(mg/l), Electrical Conductivity (EC) 77-119(µS/cm), Total suspended solids were (TSS) 20000-120000(mg/l), pH 5.31-7.09, Phosphates 2-9.2(mg/l), Alkalinity 28-160(mg/l), Turbidity, 0.02 -0.19(NTU) Total coliform 2 -48 (cfu/ml) and fungal count 1-502. Variations in the values of these parameters were only significant for phosphate, alkalinity, and turbidity between Samagidi and Okuechi at a level of significance of p≤0.05. D.O, BOD, phosphates, total coliform and TSS levels, exceeded standards recommended by NSDWQ/WHO, rendering these water sources unsuitable for drinking purposes. Cluster analysis revealed three cluster groups; cluster 1(Eku2), cluster 2(Samagidi), and cluster 3(Eku1 and Okuechi), while factor analysis showed a strong correlation with pH, D.O, BOD, phosphate, conductivity, total coliform and fungal counts with water sources in the study stations. The calculated WQI for these water sources is 107.56, 95.18, 103.45, and 110.36 for Eku I, Samagidi, Eku 2, and Okuechi, respectively, classifying them as very poor water quality and unsuitable for drinking purposes. Indiscriminate waste disposal, surface runoff and poor sanitary facilities, and the exposed nature of these wells are major contributors to the deterioration of these wells.
The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co
... Show MoreThe problem of job burnout has become one of the main problems for researchers in social welfare organizations (social protection bodies) - one of the formations of the Ministry of Labor and Social Affairs. Its negative effects increased in light of the COVID-19 pandemic, and in light of the Corona pandemic, the pressures and burdens of workers varied, which resulted in high rates of anxiety, tension, and intellectual and physical exhaustion, and then negatively affected their efficiency in performing work at the individual and organizational level, especially after the increasing tasks of these Bodies in carrying out their role in achieving the general goals and objectives as beingThe general goals are that they are responsible for providi
... Show MoreIn this research, radon concentrations in some types of healthy drinking water samples available in Iraq's market were measured using a technique called Durridge RAD-7-H2O with closed loop. Then the rate of annual effective dose in human taken this water is determined.
It was found that, radon concentrations in studied samples ranged between 1.2 Bq.m-3 to 142 Bq.m-3. The results of the radon concentrations and the rate of annual effective dose for drinking water samples were significantly lower than the USEPA and WHO recommended limits that equal 500 Bq/m3 and 1 mSv/y resp
... Show MoreLuqman's story stated that human instinct, if I was brought up properly, reaches wisdom and inflicts the right to everything. It is to go to worship God and adhere to the satisfaction of morals and high morals that are ordered to meet among human beings in this life, because this worship educates in the soul the most beautiful morals needed by human beings of honesty, honesty and modesty, and the work of good and virtues, and distancing the soul from evil and vices.
The possibility of using activated carbon developed from date palm seeds wastes as a permeable reactive barrier (PRB) to remove copper from polluted shallow groundwater was investigated. The activated carbon has been developed from date palm seeds by dehydrating methods using concentrated sulfuric acid. Batch tests were performed to characterize the equilibrium sorption properties of new activated carbon in copper-containing aqueous solutions, while the sandy soil (aquifer) was assumed to be inert. Under the studied conditions, the Langmuir isotherm model gives a better fit for the sorption data of copper by activated carbon than other models. At a pilot scale, One-dimensional column experiments were performed, and an integrated model ba
... Show MoreAbstract To ensure that the distribution system has safe drinking water. It is necessary to know the residual chlorine concentrations at various points in the network. A chlorine photometer device was used to measure twenty points taken every day for a week at a selected time in the distribution system. Both pressures and flows in the network were measured using bourdon gauge and Tuf-2000H Handheld Digital ultrasonic flow meters. WaterGEMS CONNECT Edition update one software was used to simulate the flow in the network. The Baghdad water department provided the data about the network, such as the lengths of pipes, the layout of the network, and pipes diameters. The network calibrated consists of 781 pipes of different lengths and 542 juncti
... Show MoreThis study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were
... Show MoreObjectives: To assess the psychological adjustment of middle school students and to identify the relationship between differences in demographic characteristics and psychological adjustment.
Methodology: A descriptive correlation design was used. The study utilized a simple random sample to select (381) students using self-report to select students who will be recruited into the study for the period from November 26th, 2021 to April 1st, 2022. A scale approved in the study consisting of 40 items was chosen. It measures four trends which are personal, social, familial, and emotional adjustment. The data were analyzed by applying the descriptive statistical dat
... Show MoreA chemical study was carried out to evaluate the efficiency of the liver enzyme concertation and uric acid level and its antagonists in the serum of the professors exposed to chemicals in the laboratories of the University of Samarra and their comparison with the healthy people. The research included 25 samples of the exposed professors and 20 samples as a group of officers.
The results of the current study showed a significant increase in the level of AST, ALT in the serum of professors exposed to chemicals compared to healthy people. The results showed no significant increase in
... Show MoreThe objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fix
... Show More