A new, accurate, precise and economic two spectrophotometric methods for determination of Paracetamol (Par), Ibuprofen (Ibu), and Caffeine (Caf) were suggested. Those methods were the first and second ratio derivative spectrum using a double devisor. Par, Ibu, and Caf showed many useful peaks for their quantified determination. The validity of all analysis modes for determination of the three compounds, peak to baseline, peak area and peak to peak were according to ICH. The linearity of two methods was between 5 µg/ml as a lower concentration and 50 µg/ml as the highest concentration for three compounds. Recovery percentage was around 100% and relative standard deviation was less than 2.6%. The methods were applied successfully in the determination of Par, Ibu, and Caf in pure and pharmaceutical forms.
Background: coronavirus 19 is a beta-coronavirus, enveloped and roughly spherical with approximately 60 to 140 nm in diameter with positive-sense single-stranded RNA genome.
Objectives: Measurement of interleukin 6 (IL6) level in a group of patients with confirmed Covid19 infection and its correlation with many hematological and biochemical parameters , mainly lymphocyte , neutrophil count and their ratio , platelet count , serum ferritin , C reactive protein as well as D-dimer level
Subjects and Methods: This study was conducted on 60 PCR positive patients variably affected by COVID-19 , cases collected sequentially from June till November 20
... Show MoreA sensitive and environmentally benign spectrometric method was developed for quantifying Meprobamate (MEP). The analyzed MEP was derivatized into a colored complex and determined spectrometrically. The colorimetric analytical parameters were optimized and validated. Low limit of detection (LOD) was achieved down to 1.88×10-6 mol/l while the limit of quantification (LOQ) was extended over the range of 1.97×10-6 - 1.35×10-3 mol/l. The high precision has been denoted by the 1.54% value of the coefficient of variation. The recovery was 96.07%, while the RSD (n=3) was 1.05 - 1.19%. The apparent molar absorptivity (Æ) obtained within 1154.7 - 1691.9 L.mol-1.cm
... Show MoreThis paper discusses the method for determining the permeability values of Tertiary Reservoir in Ajeel field (Jeribe, dhiban, Euphrates) units and this study is very important to determine the permeability values that it is needed to detect the economic value of oil in Tertiary Formation. This study based on core data from nine wells and log data from twelve wells. The wells are AJ-1, AJ-4, AJ-6, AJ-7, AJ-10, AJ-12, AJ-13, AJ-14, AJ-15, AJ-22, AJ-25, and AJ-54, but we have chosen three wells (AJ4, AJ6, and AJ10) to study in this paper. Three methods are used for this work and this study indicates that one of the best way of obtaining permeability is the Neural network method because the values of permeability obtained be
... Show MoreItem Difficulty and Item Discrimination Coefficient for School and College Ability Tests (SCAT) Advanced Form in Classical Test Theory (CTT) and Item Response Theory (IRT) and the Correlation among Them Mohammad moqasqas Haifa T. Albokai Assistant Professor of Measurement and Evaluation Associate Professor of Measurement and Evaluation College of Education, Taibah University The aim of this study was to study the item difficulty and item discrimination of the SCAT (advance form) with CTT, and IRT, and to study the correlation among them. To do this, the researchers used the data of their previous study, which conducted in (2011). It consisted of (3943) subject. Then, they used two-statistical programs (TAP, Bilog-MG-3) to obtain the item
... Show MoreIn the current work, the mixing ratios ( 𝛿 ) of gamma transitions were calculated from energy levels in the isotopes neodymium 60𝑁𝑎 142−150 populated in the 60Nd 142− 150 (n, n ˊγ) 60Nd 142− 150 using the 𝑎2 ratio method. We used the experimental coefficient (𝑎2 ) for two γ-transitions from the initial state itself, the statistical tensor 𝜌2(𝐽𝑖), associated with factor 𝑎2 , would be the same for the two transitions. The results obtained are in good agreement or within the experimental error with -those previously published. And existing contradictions resulting from inaccuracies in the empirical results of previous work. The current results confirm that the , 𝑎2 − method is used to calculate th
... Show MoreSeven leafhoppers (Cicadeilidae). and one plantboppei (Delpbacidae), Homoptera were identified from a one year operated light trap at the College of Agiculture farm in Abu¬Ghraib. The leafhoppers were: Balclutha hortensis Lind.; B. rufaofasciata Merine.; psammctettix alien us Dahlbem.; P. striatus L.; Extianus capicola.; Neoaliturus haematoceps H. R.; and Orozius albicnctus Dist. The planthopper was Sogatella vibix Haupt. one year records of their populations, indicated that B. rufofasciata occured during the fall from October 10 until December 18; E. capicola from October 24 until November 21 and again in the summer from March to October. The others occured only during the summer, from the end of March and early April until Mid-Septemb
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreA method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav
... Show More