A new, accurate, precise and economic two spectrophotometric methods for determination of Paracetamol (Par), Ibuprofen (Ibu), and Caffeine (Caf) were suggested. Those methods were the first and second ratio derivative spectrum using a double devisor. Par, Ibu, and Caf showed many useful peaks for their quantified determination. The validity of all analysis modes for determination of the three compounds, peak to baseline, peak area and peak to peak were according to ICH. The linearity of two methods was between 5 µg/ml as a lower concentration and 50 µg/ml as the highest concentration for three compounds. Recovery percentage was around 100% and relative standard deviation was less than 2.6%. The methods were applied successfully in the determination of Par, Ibu, and Caf in pure and pharmaceutical forms.
Two ligand ortho-amino phenyl thio benzyl (L1) and 1,3 bis (ortho - amino phenyl thio ) acetone (L2) and their complexes have been prepared and characterized . The L1 ligand is lossing phenyl group on complexcation and forming 1,2 bis (ortho - amino phenyl thio ) ethane L3 and this tetrahedrally coordinated to the metal ion ( M+2 = Ni , Cu , Cd ) and octahedrally coordinated with mercury and cobalt ions , while the ligand L2 is behave as tridentate ligand forming octahedrally around chrome metal ion . Structural , diagnosis were established by i.r , Uv- visible , conductivity elemental analysis and (mass spectra , H nmr spectra for( L1 , L2 ) .
The preparation of a new Azo compounds of highly conjugated dimeric and polymeric liquid crystal to achieve the crystalline characteristics Which have structures assigned based on elemental analysis, IR 1HNMR and CHNS-O while mesogenic properties have been set for DSC and hot-stage polarizing optical microscopy. The compounds show enantiotropicnematic phase being displayed. The compounds show photoluminescence properties in the organic solution at room temperature, with the fluorescence band centered around 400 nm.
Alizarin is one of the popularly used and wide separated compounds with a chemical name (1,2- dihydroxy-9,10-anthraquinone) which belong to the anthraquinones family that contain three aromatic conjugated rings and in the central rings it contains two ketonic groups.1
New substituted coumarins derivatives were synthesized by using nitration reaction to produce different nitro coumarin isomers which were separated from these isomers by using different solvent, and the reduction of nitro compounds was done to give corresponding amino coumarins. Temperature and reaction time of reaction were very important factors in determining the most productive nitro isotopes. A low temperature for three hours was sufficient to give a high product of a compound 6-nitro coumarin while increasing the temperature for a period of twenty-four hours that gave a high product of 8-nitro-coumarin. The synthesized compounds were confirmed by FT-IR,1 H-NMR, and13 C-NMR spectroscopy and all final compounds were tested for their ant
... Show MoreA simple, economical and selective method employing ion pair dispersive liquid−liquid microextraction (DLLME) coupled with spectrophotometric determination of carbamazepine (CBZ) in pharmaceutical preparations and biological samples was developed. The method is based on reduction of Mo(VI) to Mo(V) using a combination of ammonium thiocyanate and ascorbic acid in acidic medium to form a red binary Mo(V) thiocyanate complex. After addition of CBZ to the complex, extraction of the formed CBZ−Mo(V)−(SCN)6 was performed using a mixture of methylene chloride and methanol. Then, the measurement of target complex was performed at the wavelength of 470 nm. The important extraction parameters affecting the efficiency of DLLME were studied and o
... Show MoreAntibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, Al-Kindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18
... Show MoreIn this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma
... Show MoreAntibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, AlKindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 co
... Show MoreIn the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon