Preferred Language
Articles
/
bsj-6405
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at threshold 10%. The DD/DTA criteria are performed with 3%/3 mm and 2%/2 mm. A significant difference is shown between the measured and calculated point dose for the treatment plans. A comparison made between the gamma passing rate between the 2%/2 mm and 3%/3 mm shows a significant difference for local and global which shows that the 2%/2 mm are more sensitive to dose variation than 3%/3 mm. The total monitor unit (MU) shows a negative linear relationship with both criteria and %GP types. A significant correlation is shown between the total MU and global %GP at 2%/2 mm criterion. The conclusion of the study indicates that 2%/2 mm criterion is more sensitive to the dose distribution changes than the 3%/3 mm. The total number of monitor units should be taken into consideration during the planning of H&N tumors using the IMRT plans.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Preparation single layer of (MgO) as antireflection coating using PLD technique
...Show More Authors

In this work preparation of antireflection coating with single layer of MgO using pulsed laser deposition (PLD) method which deposit on glass substrate with different thicknesses (90 and 100) nm annealed at temperature 500 K was done.
The optical and structural properties (X-ray diffraction) have been determined. The optical reflectance was computed with the aid of MATLAB over the visible and near infrared region. Results shows that the best result obtained for optical performance of AR'Cs at 700 shots with thickness 90 nm nanostructure single layer AR'Cs and low reflection at wavelength 550 nm.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Evaluation The Performance Geodetic of the Receivers Using Static Positioning Technique
...Show More Authors

Global Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufactur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 12 2019
Journal Name
Oral And Maxillofacial Surgery
Lingual anesthesia of the lower anterior teeth, which technique is better?
...Show More Authors

Purpose To extract the lower anterior teeth, the oral surgeon needs to anesthetize the pulpal tissue of the accused tooth and the surrounding tissues. The lingual nerve innervates the lingual soft tissue to the lower teeth, this nerve usually anesthetized alongside the inferior alveolar nerve by a block technique. However, the lingual tissue of the lower anterior teeth usually anesthetized by either infiltration or periodontal ligament injection (PDL) techniques. This study was intended to compare between these two techniques. Methods Forty-eight teeth were extracted from 24 patients. Non-adjacent two lower anterior teeth in the same patient were selected. The lingual soft tissue in one of them was anesthetized by PDL injection technique wh

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Evaluation The Performance Geodetic of the Receivers Using Static Positioning Technique
...Show More Authors

Global Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufacturers, were fi

... Show More
View Publication
Crossref
Publication Date
Fri Apr 12 2019
Journal Name
Journal Of Economics And Administrative Sciences
The robust estimators of reliability function using sample technique AM & POT
...Show More Authors

Abstract 

The Phenomenon of Extremism of Values ​​(Maximum or Rare Value) an important phenomenon is the use of two techniques of sampling techniques to deal with this Extremism: the technique of the peak sample and the maximum annual sampling technique (AM) (Extreme values, Gumbel) for sample (AM) and (general Pareto, exponential) distribution of the POT sample. The cross-entropy algorithm was applied in two of its methods to the first estimate using the statistical order and the second using the statistical order and likelihood ratio. The third method is proposed by the researcher. The MSE comparison coefficient of the estimated parameters and the probability density function for each of the distributions were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reduction of Sulfur Compounds from Petroleum Fraction Using Oxidation-Adsorption Technique
...Show More Authors

Oxidation of sulfur compounds in fuel followed by an adsorption process were studied using two modes of operation, batch mode and continuous mode (fixed bed). In batch experiment oxidation process of kerosene with sulfur content 2360 ppm was achieved to study the effect of amount of hydrogen peroxide(2.5, 4, 6 and 10) ml at different temperature(40, 60 and 70)°C. Also the effect of amount acetic acid was studied  at the optimal conditions of the oxidation step(4ml H2O2 and 60 °C).Besides, the role of acetic acid different temperatures(40, 60, 70) °C and 4ml H2O2, effect of reaction time(5, 30, 60, 120, 300) minutes at temperatures(40,60) °C, 4ml H2O2 and 1 mlHAC)&

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Variables Affecting Developments of Hydroxyapatite Coating by Using Electrophoretic Deposition Technique
...Show More Authors

Electrophoretic Deposition (EPD) process offers various advantages like the fabrication of the ceramic coatings and bodies with dense packing, good sinterability and homogenous microstructure. The variables namely (applied potential, deposition time and sintering temperature) affected the development of hydroxyapatite (HAP) coatings. The coating weight and thickness were found to increase with the increase in applied potential or coating time. Sintering temperature was found to affect in change phases of the metal, furthermore the firing shrinkage of the HAP coating on a constraining metal substrate leads to serve cracking. XRD Characterization indicates the formation of a contamination free phase pure, and the optical micrographs show th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Ieee Access
Nondestructive Evaluation of Coatings Delamination Using Microwave Time Domain Reflectometry Technique
...Show More Authors

View Publication
Scopus (28)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Thu Oct 17 2024
Journal Name
South Eastern European Journal Of Public Health
Evaluation of Lifestyle for Women with Breast Cancer
...Show More Authors

Introduction: Breast cancer is a significant global health concern, affecting millions of women worldwide. While advancements in diagnosis and treatment have improved survival rates, the impact of this disease extends beyond physical health. It also significantly influences a woman's lifestyle and overall well-being. Objectives: The current study intends to analyze the lifestyle of breast cancer patients who are receiving therapy or are being followed up at the Oncology Teaching Hospital in Medical City, Baghdad, Iraq. Method: The present study uses a descriptive design with an application of an evaluation approach. A convenience sample of 100 women with breast cancer was selected from the Teaching Oncology Hospital at the Medical C

... Show More
View Publication
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Heliyon
Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study)
...Show More Authors

Objectives: This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods: Sixty cylindrical specimens (5 mm diameter ×3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was tr

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref