Nowadays, the mobile communication networks have become a consistent part of our everyday life by transforming huge amount of data through communicating devices, that leads to new challenges. According to the Cisco Networking Index, more than 29.3 billion networked devices will be connected to the network during the year 2023. It is obvious that the existing infrastructures in current networks will not be able to support all the generated data due to the bandwidth limits, processing and transmission overhead. To cope with these issues, future mobile communication networks must achieve high requirements to reduce the amount of transferred data, decrease latency and computation costs. One of the essential challenging tasks in this subject area is the optimal self-organized service placement. In this paper a heuristic-based algorithm for service placement in future networks was presented. This algorithm achieves the ideal placement of services replicas by monitoring the load within the server and its neighborhood, choosing the node that contributes with the highest received load, and finally replicating or migrating the service to it based on specific criteria, so that the distance of requests coming from clients becomes as small as possible because of placing services within nearby locations. It was proved that our proposed algorithm achieves an improved performance by meeting the services within a shorter time, a smaller bandwidth, and thus a lower communication cost. It was compared with the traditional client-server approach and the random placement algorithm. Experimental results showed that the heuristic algorithm outperforms other approaches and meets the optimal performance with different network sizes and varying load scenarios.
Background: The patient's vital signs must stay stable pre a pulmonary function test since the approach demands the patient to breathe slowly and deeply and exhale quickly. However, events that cause variations in normal vital signs may impact the patient. Many strategies can be utilized to stabilize vital signs, including music treatment. The purpose of this study is to compare the effectiveness of music therapy on the vital signs of client's pre a pulmonary function test. Methods: An experimental design study with an application (pre-test, post-test), to determine the effectiveness of music therapy for clients pre pulmonary function test for 106 clients in Al-Diwaniyah, Al-Shamiya, and Al- Hamza public hospitals In Iraq. Parti
... Show MoreThe research aimed to statement, which impact that the development of Iraqi auditing standards in the fight against corruption and to fulfill the reform requirements by conducting a comparative study analysis with a framework proposal to amend the Iraqi Audit directory number statement (6) issued by the Accounting and Auditing Standards Board of the Republic of Iraq dated 08/24/2002 on audit planning and supervision on the basis of the latest versions of international auditing standards in this regard.
The researchers concluded that there is a need to update the standards (evidence) audit accredited in the Republic of Iraq in accordance with international auditing standards to meet the requirements of the report of the external a
... Show Moreيُعد التنمر ظاهرة إجتماعية قديمة موجودة في جميع المجتمعات سواء أكان المجتمع صناعيًا أم ناميًا، كما يُعد من المفاهيم الحديثة نسبيًا، وربما يرجع لحداثة الإعتراف به نوعًا من أنواع العنف فضلاعن ندرة الدراسات التي تناولته وعدم وجود معيار محدد لتحديد السلوك الذي يعد تنمرًا أم عابرًا، لقد بدأ الأهتمام بدراسة التنمر في سبعينات القرن الماضي وأصبح موضعًا يحضى بأهتمام العديد في مختلف البلدان، وفي عصرنا الحالي تطورت
... Show MoreThe cathodic deposition of zinc from simulated chloride wastewater was used to characterize the mass transport properties of a flow-by fixed bed electrochemical reactor composed of vertical stack of stainless steel nets, operated in batch-recycle mode. The electrochemical reactor employed potential value in such a way that the zinc reduction occurred under mass transport control. This potential was determined by hydrodynamic voltammetry using a borate/chloride solution as supporting electrolyte on stainless steel rotating disc electrode. The results indicate that mass transfer coefficient (Km) increases with increasing of flow rate (Q) where .The electrochemical reactor proved to be efficient in removing zinc and was abl
... Show More