The primary objective of this paper is to improve a biometric authentication and classification model using the ear as a distinct part of the face since it is unchanged with time and unaffected by facial expressions. The proposed model is a new scenario for enhancing ear recognition accuracy via modifying the AdaBoost algorithm to optimize adaptive learning. To overcome the limitation of image illumination, occlusion, and problems of image registration, the Scale-invariant feature transform technique was used to extract features. Various consecutive phases were used to improve classification accuracy. These phases are image acquisition, preprocessing, filtering, smoothing, and feature extraction. To assess the proposed system's performance. method, the classification accuracy has been compared using different types of classifiers. These classifiers are Naïve Bayesian, KNN, J48, and SVM. The range of the identification accuracy for all the processed databases using the proposed scenario is between (%93.8- %97.8). The system was executed using MATHLAB R2017, 2.10 GHz processor, and 4 GB RAM.
Use Almtafr Alcderan orange, one of the factors Hashr Alttafaria to study Alatjabh isolates elected on the basis of specifications so that was a positive response with mutagen record and system consisting of three isolates used Alcderan orange graded concentrations and under specific Trov similar conditions Alttafar Pal NTG compared
Abstract:
Under the state scenario, fiscal policy will not be able to use the oil surpluses optimally and economically and society, as long as these surpluses are not directed by public expenditure towards new productive investments and by following the path of fiscal policy after one year 2003 and until 2013 we note that it is based on the method of spending (excessive) consumption, and did not take any action towards the budget deficit planned at the beginning of the fiscal year, and the actual surplus at the end of the fiscal year, which represents the highest expenditure in the budget, Salaries and wages of workers in various government agencies with the expansion of spending on the security side.&n
... Show MoreIn this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displaceme
... Show MoreIn the present study, nanoporous material type MCM-41 was prepared by the sol-gel technique and was used as a carrier for prednisolone (PRD) drug delivery. The structural properties of mesoporous were fully characterized by X-ray diffraction (XRD), N2 adsorption /desorption and Fourier-transform infrared (FTIR). The mass transfer in term of adsorption process (loading) and desorption process (releasing) properties were investigated. The maximum drug loading efficiency was equal to 38% and 47.5% at different concentrations. The PRD released was prudently studied in water media of pH 6.8 simulated body fluid (SBF) in according to "United State Pharmacopeia (USP38)". The results proved that the release of prednisolone from MCM-41
... Show MoreThe performance analyses of 15 kWp (kW peak) Grid -Tied solar PV system (that considered first of its type) implemented at the Training and Energy Research Center Subsidiary of Iraqi Ministry of Electricity in Baghdad city has been achieved. The system consists of 72 modules arranged in 6 strings were each string contains 12 modules connected in series to increase the voltage output while these strings connected in parallel to increase the current output. According to the observed duration, the reference daily yields, array daily yields and final daily yields of this system were (5.9, 4.56, 4.4) kWh/kWp/day respectively. The energy yield was 1585 kWh/kWp/year while the annual total solar irradiation received by solar array system was 198
... Show More