Trichomonas vaginalis is a causative agent of trichomoniasis , one of the most common non-viral sexually transmitted disease (STD) over all the world, especially in immunocompromised women such as pregnant. Wet smear and Giemsa stain are the current methods used in hospital to diagnosis trichomoniasis. DNA based diagnosis is still to be validated to diagnose the local isolates, the objective of the present study was to compare the conventional methods of disease diagnosis with the DNA-based method to diagnose Trichomonas incidence in local isolates. In the present study, 105 samples were collected from outpatient women (18-45 years) of Maternity hospital in Mosul who showed a classical presentation of Trichomonas infection including foul-smelling vaginal discharge with a pH exceeding 4.5. Samples underwent microscopic examination and nucleic acid detection of AP65-1 gene, the wet smear test showed that 16.18% of the collected specimen were positive while the parasite appeared only in 8.9% of the samples stained with Giemsa dye, the molecular screening for AP65-1gene that encodes for the surface attachment protein showed high sensitivity level of 100 at 50 specificity level in compare with other routine methods, the algorithm was evaluated according to specificity, sensitivity, and predictive values. Random Amplification Polymorphic DNA (RAPD) was achieved to estimate genetic indices among isolated strains. Phylogenetic analysis was performed using PAST (Paleontological statistics software) and dendrogram with neighboring clusters was constructed. According to the outcomes of research, we recommended to utilize a probiotic vaccines and molecular silencing vaccine (like miRNA sense and antisense oligonucleotides) as a treatment in.
Non Uniform Illumination biological image often leads to diminish structures and inhomogeneous intensities of the image. Algorithm has been proposed using Morphological Operations different types of structuring elements including (dick, line, square and ball) with the same parameters of (15).To correct the non-uniform illumination and enhancement biological images, the non-uniform background illumination have been removed from image, using (contrast adjustment, histogram equalization and adaptive histogram equalization). The used basic approach to extract the statistical features values from gray level of co-occurrence matrices (GLCM) can show the typical values for features content of biological images that can be in form of shape or sp
... Show More
A research study in which a methodology for quality indicators that can be adopted to evaluate the educational process in educational institutions within a specific strategy helps individuals in charge of educational education to make appropriate decisions based on accurate and properly approved plans to achieve successful outcomes.
These indicators can be used to judge the quality of educational institutions in order to improve, improve and develop them. This study has concluded the necessity of putting quality into actual application in order to benefit from it in evaluating the future action of Iraqi educational institutions.
The external changes brought about by technology and family life have made the
... Show MoreIn this paper, an intelligent tracking control system of both single- and double-axis Piezoelectric Micropositioner stage is designed using Genetic Algorithms (GAs) method for the optimal Proportional-Integral-Derivative (PID) controller tuning parameters. The (GA)-based PID control design approach is a methodology to tune a (PID) controller in an optimal control sense with respect to specified objective function. By using the (GA)-based PID control approach, the high-performance trajectory tracking responses of the Piezoelectric Micropositioner stage can be obtained. The (GA) code was built and the simulation results were obtained using MATLAB environment. The Piezoelectric Micropositioner simulation model with th
... Show MoreOur aim in this work is to study the classical continuous boundary control vector problem for triple nonlinear partial differential equations of elliptic type involving a Neumann boundary control. At first, we prove that the triple nonlinear partial differential equations of elliptic type with a given classical continuous boundary control vector have a unique "state" solution vector, by using the Minty-Browder Theorem. In addition, we prove the existence of a classical continuous boundary optimal control vector ruled by the triple nonlinear partial differential equations of elliptic type with equality and inequality constraints. We study the existence of the unique solution for the triple adjoint equations
... Show MoreThe aim of this research is to prove the idea of maximum mX-N-open set, m-N-extremally disconnected with respect to t and provide some definitions by utilizing the idea of mX-N-open sets. Some properties of these sets are studied.
In this work, the classical continuous mixed optimal control vector (CCMOPCV) problem of couple nonlinear partial differential equations of parabolic (CNLPPDEs) type with state constraints (STCO) is studied. The existence and uniqueness theorem (EXUNTh) of the state vector solution (SVES) of the CNLPPDEs for a given CCMCV is demonstrated via the method of Galerkin (MGA). The EXUNTh of the CCMOPCV ruled with the CNLPPDEs is proved. The Frechet derivative (FÉDE) is obtained. Finally, both the necessary and the sufficient theorem conditions for optimality (NOPC and SOPC) of the CCMOPCV with state constraints (STCOs) are proved through using the Kuhn-Tucker-Lagrange (KUTULA) multipliers theorem (KUTULATH).
The temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreIn this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies
... Show More