In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray machines, the ESD increases with age. The lowest recorded radiation dose was from hospital 1 machine 2. In this facility ESD ranged from 19.93 µGy to 67.66 µGy for chest X-ray, from 39.03 µGy to 82.63 µGy for abdomen (AP), and from 35.47 µGy to 94.27 µGy for skull (AP). In contrast the highest dose levels are recorded from hospital 2 machine 1; the minimum ESD for chest X-ray is 247.51 µGy and the maximum is 2393.12 µGy; for abdomen X-ray the lowest ESD is 269.05 µGy and the highest value is 5106.15 µGy; and for skull X-ray minimum values is 430.96 µGy and the maximum value is 3072.77 µGy. In conclusion, for the considered pediatrics examinations, most of ESD values are within the international acceptable level and some are higher >100% .
The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which
... Show MoreThe nature and intensity of the association of myasthenia gravis (MG) with distinct human leukocyte antigen (HLA) haplotypes differ between ethnic populations, so this study determined the association of HLA class II antigens with myasthenia gravis (MG) in Iraq.The study included Iraqi patients diagnosed with MG and two control groups the first of 54 insulin dependent diabetes mellitus patients and the second of 237 subjects as a normal control group. The test used was microlymphocytotoxicity test.The work was done in the Teaching Laboratories/Medical City/Baghdad.Results: positive associations were observed (etiological risk factors) as follows: 1. HLA-DR locus showed one positively associated allele when compared to healthy control and th
... Show MoreCiprofloxacin, which is a second generation of fluoroquinolone and one of the most effective and widely used drugs within fluoroquinolone. Unfamiliar adverse effects of ciprofloxacin such as bone marrow (BM) suppression, thrombocytopenia, anemia, agranulocytosis, renal failure, and others observed. Lutein, is a xanthophyll (an oxygenated carotenoid), was focused by most studies as it has a strong antioxidant activity in vitro; and also, it has been associated with reducing the risk of the age-related disorders. The current study was designed to describe the role of apoptosis through the measurement of Bcl-2 associated X protein (Bax) marker, as mechanisms of bone marrow toxicity induced by ciprofloxacin and to find whether lutei
... Show MoreA simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations
... Show MoreBackground: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16
... Show MoreBackground BK polyomavirus is one of the common post-transplant viral infections, affecting ∼15% of renal transplantation recipients (RTR), leading to graft loss in more than half of cases. Objectives Study the rate of detection of BK virus (BKV) in RTRs in Pap-stained urine cytology specimens. Methods A single center study, urine samples were collected from 99 RTR patients, with 15 Living Donors (LD) and 15 patients with chronic kidney disease (CKD) were taken as controls. And urine cytology smears were Pap stained for detection of decoy cells (DCs). Results Out of the 99 RTRs, 27 (27.3%) patients were decoy positive, 8 out of these 27 patients had uncommon DCs, and 5 out of these 27 cytology positive patients (18.5%) had biopsy proven B
... Show MoreThe influence of the grounded electrode area on the ignition voltage in capcitively coupled radio frequency discharge at 13.56 MHz in argon gas is studied experimentally. The results indicate a systematic decrease of the breakdown voltage with increasing grounded electrode area for the same pd value. Results show that the secondary ionization coefficient γ increases with the increase of grounded electrode area. Furthermore, results also the discharge current at the breakdown voltage increases almost linearly with the increase of electrode area suggesting an almost constant current density.