Preferred Language
Articles
/
bsj-5664
Collection, Storage and Protein Extraction Method of Gingival Crevicular Fluid for Proteomic Analysis
...Show More Authors

Gingival crevicular fluid (GCF) may reflect the events associated with orthodontic tooth movement. Attempts have been conducted to identify biomarkers reflecting optimum orthodontic force, unwanted sequallea (i.e. root resorption) and accelerated tooth movement. The aim of the present study is to find out a standardized GCF collection, storage and total protein extraction method from apparently healthy gingival sites with orthodontics that is compatible with further high-throughput proteomics. Eighteen patients who required extractions of both maxillary first premolars were recruited in this study. These teeth were randomly assigned to either heavy (225g) or light force (25g), and their site specific GCF was collected at baseline and after 1hr, 1day, 7days, 14days, 21days and 28days post force application. Periostrips were used for GCF collection and subsequent phosphate buffered saline (PBS) was used for immediate protein elution with centrifugal speed of 10000rpm for 5min and stored at -80°C. Protein concentration was estimated using Bradford colorimetric assay. Sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) was carried out to resolve the purity of proteins in the collected samples and the method of collection was validated by western immuno-blotting of alpha amylase salivary enzyme. The current collection, storage and protein extraction protocol showed the best protein recovery and purity with validated collection free of salivary contamination. In conclusion, tiny GCF volume from healthy sites and evaporation issues of such promising non-invasive fluid motivate us to investigate a standardized protocol enabling optimal preservation of GCF sample and the currently followed protocol may serve as a reference for future proteomic studies searching for GCF biomarkers in diagnosing and monitoring orthodontic tooth movement.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 03 2021
Journal Name
International Journal Of Energy Research
Simulation and experimentation study on the performance of metal hydride storage vessels
...Show More Authors

This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure

... Show More
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Nov 23 2020
Journal Name
Advanced Science
Association of Fluorescent Protein Pairs and Its Significant Impact on Fluorescence and Energy Transfer
...Show More Authors

View Publication
Scopus (16)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % were

... Show More
Crossref (5)
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Applied Mathematical Modelling
Potential flow of fluid from an elevated, two-dimensional source
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (3)
Crossref
Publication Date
Sat Jul 21 2018
Journal Name
Plant Archives
EXTRACTION, ANTIMICROBIALACTIVITYAND PHYTOCHEMICAL OF CLERODENDRUM VISCOSUM
...Show More Authors

Clerodendrum plant is believed to be very useful in many countries for treating various health disorders .“in this study was undertaken to assess antimicrobial activity of ethanol and aqueous extracts of clerodendrum plant”. Display my alcoholic extract higher inhibition of the aqueous extract all of the bacteria (Esherichia Coli , Pseudomonas aeruginosa, Bacillus subtilis). While the inhibition of the aqueous extract bacteria (Streptococcus, Shigelladysenteria) in higher alcoholic extract. However, the bacteria (Klebseillapneumoniae) did not shown any inhibition zone for both aqueous and alcoholic extracts. From the above results,“ it is concluded the antibacterial properties of Clerodendrum against life threatening pathogens”. So,

... Show More
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
FINITE ELEMENT METHOD FOR INCOMPRESSIBLE VISCOELASTIC MATERIALS
...Show More Authors

A numerical method (F.E.)was derived for incompressible viscoelastic materials, the aging and
environmental phenomena especially the temperature effect was considered in this method. A
treatment of incompressibility was made for all permissible values of poisons ratio. A
mechanical model represents the incompressible viscoelastic materials and so the properties can
be derived using the Laplace transformations technique .A comparison was made with the other
methods interested with viscoelastic materials by applying the method on a cylinder of viscoelastic material surrounding by a steel casing and subjected to a constant internal pressure, as well as a comparison with another viscoelastic method and for Asphalt Concrete pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 03 2022
Journal Name
Tikrit Journal Of Pure Science
A Pixel Based Method for Image Compression
...Show More Authors

The basic solution to overcome difficult issues related to huge size of digital images is to recruited image compression techniques to reduce images size for efficient storage and fast transmission. In this paper, a new scheme of pixel base technique is proposed for grayscale image compression that implicitly utilize hybrid techniques of spatial modelling base technique of minimum residual along with transformed technique of Discrete Wavelet Transform (DWT) that also impels mixed between lossless and lossy techniques to ensure highly performance in terms of compression ratio and quality. The proposed technique has been applied on a set of standard test images and the results obtained are significantly encourage compared with Joint P

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
New Iterative Method for Solving Nonlinear Equations
...Show More Authors

The aim of this paper is to propose an efficient three steps iterative method for finding the zeros of the nonlinear equation f(x)=0 . Starting with a suitably chosen , the method generates a sequence of iterates converging to the root. The convergence analysis is proved to establish its five order of convergence. Several examples are given to illustrate the efficiency of the proposed new method and its comparison with other methods.

View Publication Preview PDF
Crossref