This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) buffer to yield a reddish/orange colour change proportional to the iron(II) concentration measured at λmax = 510 nm. Under optimum conditions, the calibration curve was linear in the range between (0.5-150) mg L-1 with a limit of detection of 0.09 mg L-1. Compared to a spectrophotometric detection method, µPAD measured colour intensity using captured images using Samsung mobile phone and image J program to give proof of concept that µPAD platform fulfils the purpose of accuracy and at the same time remaining cost-effective and simplistic to be used in both developing and developed countries gave same linear calibration curve with a limit of detection 0.12 mg L-1. ANOVA test was used to compare the proposed method results with conventional method results showing the method was accepted. The antimicrobial activity showed no significant effect from lipstick samples on tested microbes.
The ring modulator described in part I of this paper is designed here for two operating wavelengths 1550nm and 1310nm. For each wavelength, three structures are designed corresponding to three values of polymer slot widths (40, 50 and 60nm). The performance of these modulators are simulated using COMSOL software (version 4.3b) and the results are discussed and compared with theoretical predictions. The performance of intensity modulation/direct detection short range and long rang optical communication systems incorporating the designed modulators is simulated for 40 and 100Gb/s data rates using Optisystem software (version 12). The results reveal that an average energy per bit as low as 0.05fJ can be obtained when the 1550nm modulator is d
... Show MoreThe aim of the present study is to evaluate the change in the levels of glucagon, GLP-1 and GPCR in diabetic patient's and diabetic with dyslipidemia as metabolic syndrome. The study included 75 male aged ranged (30-50) years and with BMI (25-29) kg/m2 which divided into three groups as follows: group one (G1): consist of 25 subjects as healthy control group. Group two (G2): consist of 25 patient's with diabetes mellitus and group three (G3): consist of 25 patient's with diabetic and dyslipidemia as metabolic syndrome. Serum was used in determination of FBG, lipid profile, insulin, glucagon, GLP-1 and GPCR. Whole blood was determination of HbA1c. The results revealed significant elevation in FBG and HbA1c in G2 and G3 comparing to G1. While
... Show MoreLinear regression is one of the most important statistical tools through which it is possible to know the relationship between the response variable and one variable (or more) of the independent variable(s), which is often used in various fields of science. Heteroscedastic is one of the linear regression problems, the effect of which leads to inaccurate conclusions. The problem of heteroscedastic may be accompanied by the presence of extreme outliers in the independent variables (High leverage points) (HLPs), the presence of (HLPs) in the data set result unrealistic estimates and misleading inferences. In this paper, we review some of the robust
... Show MoreBackground: Patient satisfaction is of increasing importance and widely recognized as an important indicator of quality of the medical care. There was no homogeneous definition of patient satisfaction, since satisfaction concerns different aspects of care or settings, as well as care given by various professions.
Objective: The objective of this study is to assess the patients’ level of satisfaction with diabetes care and to identify the underlying factors influencing it.
Methods: This cross-sectional study had been conducted in the Specialized Center for Diabetes and Endocrinology in Baghdad Al- Rusafa 2018. Where150 type two diabetic patients attending their follow-up
... Show MoreBackground: Periodontal diseases are inflammatory diseases affecting the supporting tissues of the teeth. One of the leading environmental factors that are closely related not only to the risk but also to the prognosis of periodontitis is smoking. This study aimed to evaluate the influence of smoking on periodontal health status and to measure the levels of matrix metalloproteinase-9 in smokers and nonsmokers chronic periodontitis patients, also it aimed to test the correlation between the levels of matrix metalloproteinase-9 and the clinical periodontal parameters. Materials and Methods: Five milliliters samples of un-stimulated whole saliva and full-mouth clinical periodontal recordings (plaque index, gingival index, bleeding on probing,
... Show MoreBackground: The value of lateral cephalometric radiographs to evaluate the pharyngeal airway is limited because it provided 2-dimensional (2D) images of complex 3-dimensional (3D) anatomic structures. Three dimensional analyses of the airway volumes are required to understand oral and pharyngeal adaptations in mouth breathing and nasal breathing subjects. The aim of this study was to measure the pharyngeal airway volume and the size of the face, then compare between pharyngeal airway volume in mouth breathing and nasal breathing subjects and find the gender difference in each group, also to study the relation between pharyngeal airway volume and the size of the face. Material and Methods: Fifty patients including 28 males and 22 females wit
... Show MoreThis study was carried out to measure the percentage of heavy metals pollution in the water of the Diyala river and to measure the percentage of contamination of these elements in the leafy vegetables grown on both sides of the Diyala river, which are irrigated by the contaminated river water (celery, radish, lepidium, green onions, beta vulgaris subsp, and malva). Laboratory analysis was achieved to measure the ratio of heavy element contamination (Pb, Fe, Ni, Cd, Zn and Cr) using flame atomic absorption spectrophotometer during the summer months of July and August for the year 2017. The study showed that the elements of zinc, chromium, nickel and cadmium were high concentrations and exceeded. The maximum concentration of these
... Show MoreA comparison of double informative and non- informative priors assumed for the parameter of Rayleigh distribution is considered. Three different sets of double priors are included, for a single unknown parameter of Rayleigh distribution. We have assumed three double priors: the square root inverted gamma (SRIG) - the natural conjugate family of priors distribution, the square root inverted gamma – the non-informative distribution, and the natural conjugate family of priors - the non-informative distribution as double priors .The data is generating form three cases from Rayleigh distribution for different samples sizes (small, medium, and large). And Bayes estimators for the parameter is derived under a squared erro
... Show MoreThe problem of the damage caused by terrorist acts has raised many difficulties in many countries, including Iraq, which requires the existence of a law that sets out sufficient rules for compensating the victims of terrorist acts, in order to compensate them for the harm they have not suffered. It may be difficult or impossible for them to identify causing damage, and therefore unable to obtain compensation by applying the traditional rules of liability that require proof of fault and identify the culprit. The security funds come as an appropriate alternative that pays compensation in such cases for victims to reparation for the damage they suffered. Therefore, this problem remains one of the most problems that Iraq suffers from it, which
... Show MoreAbstract
In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3 have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r
... Show More