Preferred Language
Articles
/
bsj-527
Determination of Serum CA125 and evaluate its efficiency as screening tool For Early Detection of Ovarian Tumors
...Show More Authors

Epithelial ovarian cancer is the leading cause of cancer deaths in women. To date, an effective screening tool for ovarian cancer has not been identified Several clinical and biological factors including serum cancer antigen 125 (CA- 125) have been assessed for prognostic and predictive relevance CA-125 is an epithelial marker derived from coelomic epithelium. It is elevated in 90% of advanced ovarian cancers and in 50% of early ovarian cancers while 20% of ovarian cancers have low or no expression of CA- 125 CA-125 concentrations were measured by Mini Vidas test (VIDAS CA125 II / BIOMERIEUX / France). The median CA-125 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors and in healthy controls. However in correlation with stages the results showed that Patients with stage II have highly significant differences in level of serum CA125 compare with stage I in and stage III.CA125 showed low sensitivity to detect stage I carcinoma of the ovary which limits its value as an initial screening tool therefore combining of CA125 with other markers might enable improved early detection of ovarian cancer as compared with use of this marker alone.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Aug 21 2022
Journal Name
International Journal Of Health Sciences
Molecular detection of fimH& mrkDgenes of strong biofilm producers & MDR Klebsiella pneumoniae
...Show More Authors

Klebsiella pneumoniae is an adaptable pathogen that forms biofilms on a variety of surfaces. This study's objective was to identify the presence of fimbrial genes (types 1 and 3) in K. pneumoniae strains isolated from various clinical sources based on their antibiotic resistance and ability to form biofilms. According to identification utilizing the vitek 2 technology and confirmation by molecular identification targeting the 16S rRNA gene with a particular primer, forty isolates were identified from clinical specimens. The vitek 2 compact system was utilized to evaluate the antibiotic susceptibility of all the isolates. The findings revealed a range of resistance percentages, including 52.5% for Penicillin, 40.5% for Trimethoprim/S

... Show More
View Publication
Crossref
Publication Date
Sat Jun 15 2024
Journal Name
Iraqi Journal Of Laser
Estimation of mean photon number based on single photon detection of weak coherent pulses
...Show More Authors

The demand for single photon sources in quantum key distribution (QKD) systems has necessitated the use of weak coherent pulses (WCPs) characterized by a Poissonian distribution. Ensuring security against eavesdropping attacks requires keeping the mean photon number (µ) small and known to legitimate partners. However, accurately determining µ poses challenges due to discrepancies between theoretical calculations and practical implementation. This paper introduces two experiments. The first experiment involves theoretical calculations of µ using several filters to generate the WCPs. The second experiment utilizes a variable attenuator to generate the WCPs, and the value of µ was estimated from the photons detected by the BB

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
DETECTION OF sHLA-G PROTEINS IN THE SERA OF PATIENTS INFECTED WITH VISCERAL LEISHMANIASIS
...Show More Authors

Visceral leishmaniasis (VL) or kala-azar is one of the worlds most neglected tropical diseases in mortality and fourth in morbidity, rK39 dipstick was used to diagnose the suspected infected patients as cheapest simple technique which can differentiate recent from chronic infection, for disease out-coming, naïve T-lymphocyte cells should be differentiated into pathogen-specific immunity responses, such as T-helper 1(Th-1) or (Th-2). HLA-G is a special protein defined as nonclassical HLA class I molecule can suppress the immune system through prevention of T-cell function by foul all T-cell mechanisms. So, this study aimed to detect and evaluate the level of sHLA-G in the sera of patients infected with VL. The results showed that there was

... Show More
Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
World Journal Of Experimental Biosciences
Detection of anti-Helicobacter pylori antibodies in sera of women with recurrent spontaneous abortion
...Show More Authors

To determine the relationship between Helicobacter pylori infection and reproduction disorder (recurrent spontaneous abortion), twenty women patients who undergo spontaneous abortion during first trimester of pregnancy (20-38) years and have been investigated from 2015/12/1 -2016/3/1 and compared to fifteen healthy individuals. All subjects were carried out to measure anti-H. pylori IgA and anti- H. pylori IgG antibodies by enzyme linked immunosorbent assay (ELISA). There was significant elevation (p≤ 0.05) in concentration of anti- H. pylori IgG Abs (6.30± 0.99) compared to control group (4.48± 0.61) and IgA Abs (5.42 ± 0.90 U /ml) as compared to control group (3.92 ± 0.41 U/ml). The percentage of H. pylori IgG and IgA was 20% and 25

... Show More
Publication Date
Sun Jun 02 2024
Journal Name
Methods And Objects Of Chemical Analysis
Simultaneous Spectrophotometric Determination of Piroxicam, Naproxen, Diclofenac Sodium and Mefenamic Acid in Pharmaceutical Formulations by Partial Least Squares Method
...Show More Authors

A chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Apr 10 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified with Functionalized Graphene Oxide
...Show More Authors

Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×

... Show More
Preview PDF
Publication Date
Mon Jun 10 2019
Journal Name
Chemistry &chemical Technology
Quantitative Determination of Ephedrine Hydrochloride in Pharmaceutical Injections by Highly Sensitive Turbidimetric and Reversed-Phase Combined with UFLC Methods
...Show More Authors

In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi Journal Of Science
Assessing the Potentiality of Using CXCL9 as A Predictive Biomarker for Acute and Chronic Toxoplasmosis, and Study the Correlation Between CXCL9, Toxoplasmosis and Thyroid Disorder in These Cases
...Show More Authors

     Background:  Chemokine (C-X-C motif) ligand (CXCL9) has an important role recruiting the T-lymphocytes and immune response after infection by inducing T-cells accumulation around the areas associated with infections. However, this role is poorly known in relation with Toxoplasma gondii infection and also in association with thyroid hormones, which the present study is focused on. Methods: Eighty-seven women were included in this study for the period between September 2021 and February 2022. Blood samples of uninfected healthy pregnant, in addition to aborted and pregnant women infected with toxoplasmosis, were collected. Sera were then obtained and stored at -10°C. Toxo-latex agglutination test was done, followed by detec

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Validity of Hounsfield Units from computed tomographic images of mandibular bone in detection of osteoporosis
...Show More Authors

Background: The figure for the clinical application of computed tomography have been increased significantly in oral and maxillofacial field that supply the dentists with sufficient data enables them to play a main role in screening osteoporosis, therefore Hounsfield units of mandibular computed tomography view used as a main indicator to predict general skeleton osteoporosis and fracture risk factor. Material and Methods: Thirty subjects (7 males &23 females) with a mean age of (60.1) years underwent computed tomographic scanning for different diagnostic assessment in head and neck region. The mandibular bone quality of them were determined through Hounsfield units of CT scan images and were correlated with the bone mineral density v

... Show More
View Publication Preview PDF