Preferred Language
Articles
/
bsj-527
Determination of Serum CA125 and evaluate its efficiency as screening tool For Early Detection of Ovarian Tumors
...Show More Authors

Epithelial ovarian cancer is the leading cause of cancer deaths in women. To date, an effective screening tool for ovarian cancer has not been identified Several clinical and biological factors including serum cancer antigen 125 (CA- 125) have been assessed for prognostic and predictive relevance CA-125 is an epithelial marker derived from coelomic epithelium. It is elevated in 90% of advanced ovarian cancers and in 50% of early ovarian cancers while 20% of ovarian cancers have low or no expression of CA- 125 CA-125 concentrations were measured by Mini Vidas test (VIDAS CA125 II / BIOMERIEUX / France). The median CA-125 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors and in healthy controls. However in correlation with stages the results showed that Patients with stage II have highly significant differences in level of serum CA125 compare with stage I in and stage III.CA125 showed low sensitivity to detect stage I carcinoma of the ovary which limits its value as an initial screening tool therefore combining of CA125 with other markers might enable improved early detection of ovarian cancer as compared with use of this marker alone.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Chromium Using Indigo Carmine -Application in Various Samples
...Show More Authors

A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Carbofuran with Diazotized Benzidine in Environmental Water Samples
...Show More Authors

A simple, rapid, accurate and sensitive spectrophotometric method has been developed for the determing carbamate pesticides in both pure and water samples. The method is appropriate for the determination of carbofuran in the presence of other ingredients that are usually available in dosage forms. The effect of organic solvents on the spectrophotometric properties of the azo dye and the structure of the resulting product have also been worked out and it is found to be 1:1 benzidine :carbofuran. The method can be successfully applied to determination of carbofuran in water samples. The method is based on diazotization of Benzidine (4, 4 – diamino biphenyl) with sodium nitrite and hydrochloric acid followed by coupling with carbofuran

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Spectrophotometric Determination of Ampicillin with Sulfanilic Acid by Oxidative Coupling Reaction
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Feb 20 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Some Polychlorinated Biphenyls in River Tigris within Baghdad City
...Show More Authors

A number of aqueous samples were collected from river Tigris in Baghdad city, enriched ~1000 times using solid phase extraction (SPE), then extracted the trace concentrations of some polychlorinated biphenyls (PCB) using an aqueous two-phase system (ATPS) composed of 1Methylpyridinium chloride [MePy]Cl and KH2PO4 salt. High performance liquid chromatography technique coupled with ultraviolet (HPLC-UV) is used for the quantification. Extraction under the optimized conditions of pH, solvent composition, duration and temperature has given with a yield of PCB about 91%. The limit of detection (LOD) and limit of quantification (LOQ) for analyses are 0.11-0.62 µg.L−1 and 2.67–3.43 µg.L−1 respectively with relative stan

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Spectrophotometric Determination of Olanzapine via Coupling with Diazotized p-Nitroaniline
...Show More Authors

A new spectrophotometric method has been developed for the assay of olanzapine (OLN.) in pure and dosage forms. The method is based on the diazocoupling of (OLN.) with diazotized p-nitroaniline in alkaline medium to form a stable brown colored water-soluble azo dye with a maximum absorption at 405 nm.  The variables that affect the completion of reaction have been carefully optimized. Beer’s law is obeyed over the concentration range of (0.5-45.0 μg.mL-1) with a molar absorptivity of 1.5777×104 L.mol-1.cm-1.  The limit of detection was  0.3148  Î¼g.mL-1 and  Sandell’s  sensitivity value was 0.0198 μg.cm-2. The propose

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 02 2021
Journal Name
International Journal Of Pharmaceutical Research
Detection of Kaposi’s Associated Herpesvirus in Saliva of Drug Related Immunosupressed Patient
...Show More Authors

View Publication
Crossref
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF
Publication Date
Mon Dec 02 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability
Effect of thickness variation CdO/PSi thin films on detection of radiation
...Show More Authors

CdO films were deposited on substrates from glass, Silicon and Porous silicon by thermal chemical spray pyrolysis technique with different thicknesses (130 and 438.46) nm. Measurements of X-ray diffraction of CdO thin film proved that the structure of the Polycrystalline is cubic lattice, and its crystallite size is located within nano scale range where the perfect orientation is (200). The results show that the surface’s roughness and the root mean square increased with increasing the thickness of prepared films. The UV-Visible measurements show that the CdO films with different thicknesses possess an allowed direct transition with band gap (4) eV. AFM measurement revealed that the silicon porosity located in nano range. Cadmium oxide f

... Show More
Scopus (2)
Scopus
Publication Date
Tue Jun 30 2020
Journal Name
Iraq Journal Of Market Research And Consumer Protection
DETECTION OF HEAVY METALS POLLUTION INTYPES OF MILK SAMPLES IN BAGHDAD MARKETS
...Show More Authors

View Publication
Crossref
Publication Date
Wed Jul 10 2024
Journal Name
The Open Neuroimaging Journal
The Efficacy of Bedside Chest Ultrasound in the Detection of Traumatic Pneumothorax
...Show More Authors
Background

Chest X-rays have long been used to diagnose pneumothorax. In trauma patients, chest ultrasonography combined with chest CT may be a safer, faster, and more accurate approach. This could lead to better and quicker management of traumatic pneumothorax, as well as enhanced patient safety and clinical results.

Aim

The purpose of this study was to assess the efficacy and utility of bedside US chest in identifying traumatic pneumothorax and also its capacity to estimate the extent of the lesion in comparison to the gold standard modality chest computed tomography.

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref