Preferred Language
Articles
/
bsj-527
Determination of Serum CA125 and evaluate its efficiency as screening tool For Early Detection of Ovarian Tumors
...Show More Authors

Epithelial ovarian cancer is the leading cause of cancer deaths in women. To date, an effective screening tool for ovarian cancer has not been identified Several clinical and biological factors including serum cancer antigen 125 (CA- 125) have been assessed for prognostic and predictive relevance CA-125 is an epithelial marker derived from coelomic epithelium. It is elevated in 90% of advanced ovarian cancers and in 50% of early ovarian cancers while 20% of ovarian cancers have low or no expression of CA- 125 CA-125 concentrations were measured by Mini Vidas test (VIDAS CA125 II / BIOMERIEUX / France). The median CA-125 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors and in healthy controls. However in correlation with stages the results showed that Patients with stage II have highly significant differences in level of serum CA125 compare with stage I in and stage III.CA125 showed low sensitivity to detect stage I carcinoma of the ovary which limits its value as an initial screening tool therefore combining of CA125 with other markers might enable improved early detection of ovarian cancer as compared with use of this marker alone.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 03 2017
Journal Name
Journal Of Babylon University
Spectrophotometric Determination of Sulfamethoxazole in Pure and Pharmaceutical Preparations Based on Condensation Reaction Method
...Show More Authors

A new, Simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sulfamethoxazole (SMZ) drug in pure and dosage forms. This method based on the reaction of sulfamethoxazole (SMZ) with 1,2-napthoquinone-4-sulphonic acid (NQS) to form Nalkylamono naphthoquinone by replacement of the sulphonate group of the naphthoquinone sulphonic acid by an amino group. The colored chromogen shows absorption maximum at 460 nm. The optimum conditions of condensation reaction forms were investigated by (1) univariable method, by optimizing the effect of experimental variables (different bases, reagent concentration, borax concentration and reaction time), (2) central composite design (CCD) including the effect of

... Show More
Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Simultaneous Ratio Derivative Spectrophotometric Determination of Paracetamol, Caffeine and Ibuprofen in Their Ternary Form
...Show More Authors

A new, accurate, precise and economic two spectrophotometric methods for determination of Paracetamol (Par), Ibuprofen (Ibu), and Caffeine (Caf) were suggested. Those methods were the first and second ratio derivative spectrum using a double devisor. Par, Ibu, and Caf showed many useful peaks for their quantified determination. The validity of all analysis modes for determination of the three compounds, peak to baseline, peak area and peak to peak were according to ICH. The linearity of two methods was between 5 µg/ml as a lower concentration and 50 µg/ml as the highest concentration for three compounds. Recovery percentage was around 100% and relative standard deviation was less than 2.6%. The methods were applied successfully in the

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bisacodyl in Pure and Pharmaceutical Preparation via Oxidative Coupling Organic Reaction
...Show More Authors

A simple, accurate and sensitive spectrophotometric way is used to determine Bisacodyl in pure and pharmaceutical preparations. The proposed method depends on using 2,4-Dinitrophenylhydrazine as chromogenic reagent . The method was based on the oxidative coupling reaction of Bisacodyl with 2,4-Dinitrophenylhydrazine with Sodium periodate in the presence of sodium hydroxide as alkaline media to form red water soluble dye product , that has a maximum absorption at ?max 522nm . Beer ,s law is obeyed in the concentration of (2.00–20.00) ?g.ml -1 .The molar absorptivity is (6505) L.mol-1.cm-1,a sandall sensitivity of(0.0555) ?g.cm-2), correlation coefficient of (0.9970) , Limitof detection (LOD) (0.0312 ?g.ml-1), limit of Quantitation (LOQ) (

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Determination and evaluation of principal minerals in Negella sativa by atomic absorption technical methods
...Show More Authors

Determination and evaluation of principal minerals in Negella sativa by atomic absorption technical methods were showed, using wet ashing method. This work was done on Negella sativa because of wide using of this plant in many formulations ( in food or medicine ).two types of atomic absorptions were used : first, flame atomic absorption spectroscopy, for minerals of high concentrations such as, Na, Mg, K, Fe, Ca, Li, Ni, Zn, Mn, Cu. Second, flameless atomic absorption spectroscopy, for minerals of low concentrations such as, Al, Si, V, B, Pb, Co, Cd, Cr ,Si, Hg, Sn .The results showed the existence of many minerals in Negella sativa useful to human sanity with acceptable dietary allowance. On other side, the presence of harmful m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Reservoir Hydraulic Flow Units and Permeability Estimation Using Flow Zone Indicator Method
...Show More Authors

   Reservoir characterization plays a crucial role in comprehending the distribution of formation properties and fluids within heterogeneous reservoirs. This knowledge is instrumental in constructing an accurate three-dimensional model of the reservoir, facilitating predictions regarding porosity, permeability, and fluid flow distribution. Among the various methods employed for reservoir characterization, the hydraulic flow unit stands out as a widely adopted approach. By effectively subdividing the reservoir into distinct zones, each characterized by unique petrophysical and geological properties, hydraulic flow units enable comprehensive reservoir analysis. The concept of the flow unit is closely tied to the flow zone indicator, a cr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 06 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Contributing Risk Factors to Adult Nephrolithiasis Patients
...Show More Authors

Objectives: To determine the contributing risk factors to adult nephrolithiasis patients.
Methodology: A descriptive study was conducted to determine the contributing risk factors to
Adults nephrolithiasis starting from December 2007 to September 2008. A purposive "nonprobability"
sample of (100) patients with nephrolithiasis was selected of those who were
admitted to the hospitals, attending the Urology Consultation Clinic and Extracorporeal Shock
Wave Lithotripsy Department. The study instrument consists of two parts. The first part is
related to the patients' demographic variables and the second part is constructed to serve the
purpose of the study. The total number of items in the questionnaire was (85) ones.

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2008
Journal Name
Journal Of Al-nahrain University
DETERMINATION THE AGE OF GALAXIES USING STRONG GRAVITATIONAL LENSING
...Show More Authors

Most of the known cases of strong gravitational lensing involve multiple imaging of an active galactic nucleus. The properties of lensed active galactic nuclei make them promising systems for astrophysical applications of gravitational lensing. So we present a simple model for strong lensing in the gravitational lensed systems to calculate the age of four lensed galaxies, in the present work we take the freedman models with (k curvature index =0) Euclidian case, and the result show a good agreement with the other models.

Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric determination of cefixime by charge transfer complex formation
...Show More Authors

Simple, sensitive and economical spectrophotometric methods have been developed for the determination of cefixime in pure form. This method is based on the reaction of cefixime as n-electron donor with chloranil to give highly colored complex in ethanol which is absorb maximally at 550 nm. Beer's law is obeyed in the concentration ranges 5-250 µg ml-1 with high apparent molar absorptivities of 1.52×103 L.mole-1. cm-1.

View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Brazilian Journal Of Analytical Chemistry
Determination of insecticides in different commercialformulations by Gradient HPLC
...Show More Authors

A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.

... Show More
Publication Date
Wed Aug 20 2025
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication