In this paper new methods were presented based on technique of differences which is the difference- based modified jackknifed generalized ridge regression estimator(DMJGR) and difference-based generalized jackknifed ridge regression estimator(DGJR), in estimating the parameters of linear part of the partially linear model. As for the nonlinear part represented by the nonparametric function, it was estimated using Nadaraya Watson smoother. The partially linear model was compared using these proposed methods with other estimators based on differencing technique through the MSE comparison criterion in simulation study.
In the nineteenth century, a new type of cities appeared, known as new cities located on the edges of major cities, and these cities began to decentralization, urban studies turned to this type of cities to find out the most important reasons for the emergence of new cities and find out what those cities will become . Therefore, we will discuss in this research how the urban emergence of these cities (edge cities) occurs, so the research formulates its problem : The need to know the stages that edge cities go through, ending with their emergence, and the mechanisms that cities take within their context ( regeneration or adaptation ), Assuming that edge cities are a
... Show MoreIn this paper, A.C conductivity of micro and nano grain size- TiO2 filled epoxy composites is measured. The dielectric material used is epoxy resin, while micro and nano-sized titanium dioxide (TiO2) of grain size (1.5μm, and 50nm) was used as filler at low filler concentrations by weight (3%, and 5%). Additionally the effect of annealing temperature range (293-373)º K and at a frequency range of 102-106 Hz on the A.C conductivity of the various specimens was studied.
The result of real permittivity for micro and nanocomposite show that the real permittivity increases with decreasing frequency at range of 102-106Hz. The micron-filled material has a higher real relative permittivity than the nano-filled this is true at all the temper
The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser
n this work, a series of new nucleoside analogues (β-glucose liked to pyrazoline moiety) was synthesized. In the beginning, chalcone [1-3] was formed from the reaction of acetophenone and benzaldehyde derivatives in the presence of sodium hydroxide. Pyrazolines [4-6] were obtained from the reaction of the prepared chalcones and hydrazine hydrate in the presence of ethanol absolute. These pyrazolines were treated with β-glucose pentaacetate to afford a series of desirable protected nucleoside analogues [8-10]. After that hydrolysis of protected nuclioside analogues in sodium methoxide gave free nucleoside analogues [11-13]. These new formed compounds were diagnosed by 13C-NMR and 1H- NMR for some of them and FT-IR spectroscopy.
This study was carried out to prepare and characterize domperidone nanoparticles to enhance solubility and the release rate. Domperidone is practically insoluble in water and has low and an erratic bioavailability range from 13%-17%. The domperidone nanoparticles were prepared by solvent/antisolvent precipitation method at different polymer:drug ratios of 1:1 and 2:1 using different polymers and grades of poly vinyl pyrolidone, hydroxy propyl methyl cellulose and sodium carboxymethyl cellulose as stabilizers. The effect of polymer type, ratio of polymer:drug, solvent:antisolvent ratio, stirring rate and stirring time on the particle size, were investigated and found to have a significant (p? 0.05) effect on particle size. The best formul
... Show More
