Separation of Trigonelline, the major alkaloid in fenugreek seeds, is difficult because the extract of these seeds usually contains Trigonelline, choline, mucilage, and steroidal saponins, in addition to some other substances. This study amis to isolate the quaternary ammonium alkaloid (Trigonelline) and choline from fenugreek seeds (Trigonella-foenum graecum L.) which have similar physiochemical properties by modifying of the classical method. Seeds were defatted and then extracted with methanol. The presence of alkaloids was detected by using Mayer's and Dragendorff's reagents. In this work, trigonilline was isolated with traces of choline by subsequent processes of purification using analytical and preparative TLC techniques. Further identification was done by using HPLC, IR and MP. Pure Trigonelline was isolated from the seeds of Trigonella-foenum graecum excluding other alkaloid like choline. In this study, a new, fast and convenient method for isolation and purification of Trigonelline from fenugreek seeds has been established. Unlike other methods, this one excludes all the non-alkaloidal components from the fenugreek seeds extract.
Chalcopyrite thin films were one-step potentiostatically deposited onto stainless steel plates from aqueous solution containing CuSO4, In2(SO4)3 and Na2S2O3.The ratio of (In3+:Cu2+) which involved in the solution and The effect of cathodic potentials on the structural had been studied. X-ray diffraction (XRD) patterns for deposited films showed that the suitable ratio of (In3+:Cu2+) =6:1, and suitable voltage is -0.90 V versus (Ag/AgCl) reference electrode
Radiation measuring devices need to process calibration which
lose their sensitivity and the extent of the response and the amount of
stability under a changing conditions from time to time and this
period depends on the nature and use of field in which used devices.
A comparison study was done to a (451P) (ionization chamber
survey meter) and this showed the variation of calibration factor in
five different years. This study also displayed the concept of
radiation instrument calibration and necessity of every year
calibration of them.
In this project we used the five years calibration data for ionization
chamber survey meter model Inspector (451P) to get that the values
of Calibration Factor (CF) and Res
During the syrvey on natural enemies of whiteflies in Iraq, the following. predators were recorded.
This is a survey study that presents recent researches concerning factional controllers. It presents several types of fractional order controllers, which are extensions to their integer order counterparts. The fractional order PID controller has a dominant importance, so thirty-one paper are presented for this controller. The remaining types of controllers are presented according to the number of papers that handle them; they are fractional order sliding mode controller (nine papers), fuzzy fractional order sliding mode controller (five papers), fractional order lag-lead compensator (three papers), fractional order state feedback controller (three papers), fractional order fuzzy logic controller (three papers). Finally,
... Show MoreRoller Compacted Concrete (RCC) is a technology characterized mainly by the use of rollers for compaction; this technology achieves significant time and cost savings in the construction of dams and roads. The primary scope of this research is to study the durability and performance of roller compacted concrete that was constructed in the laboratory using roller compactor manufactured in local market. A total of (60) slab specimen of (38×38×10) cm was constructed using the roller device, cured for 28 days, then 180 sawed cubes and 180 beams are obtained from RCC slab. Then, the specimens are subjected to 60 cycles of freezing and thawing, sulfate attack test and wetting and drying. The degree of effect of the type of coarse aggregate (c
... Show MoreIn this study, the kinetics for the reaction of tert-butanol esterification with acetic acid in the presence of Dowex 50Wx8 catalyst was investigated. The reaction kinetic experiments were conducted in 1000 milliliter vessel at temperatures ranged from 50 - 80 oC, catalyst loading 25-50 g/L, and the molar ratios of acetic acid to tert-butanol from 1/3 – 3/1. The reaction rate was found to increase with increasing temperature and catalyst loading. It was also found the conversion of the tert-butanol increases as the molar ratio of acid to alcohol increases from 1/3 – 3/1. The Non-ideality of the liquid phase was taken into account by using activities instead of molar fractions. The activity coefficients were calculated according to th
... Show More


