Mycobacterium tuberculosis resistance to rifampicin is mainly mediated through mutations in the rpoB gene. The effects of rpoB mutations are relieved by secondary mutations in rpoA or rpoC genes. This study aims to identify mutations in rpoB, rpoA, and rpoC genes of Mycobacterium tuberculosis isolates and clarify their contribution to rifampicin resistance. Seventy isolates were identified by acid-fast bacilli smear, Genexpert assay, and growth on Lowenstein Jensen medium. Drug susceptibility, testing was performed by the proportional method. DNA extraction, PCR, and sequencing were accomplished for the entire rpoA, rpoB, and rpoC genes. Twenty-three isolates (32.85%) showed resistance to rifampicin by either proportion method or Genexpert assay. Sequence analysis of the rpoB gene revealed fourteen different mutation patterns. Inside the rifampicin resistance determining region (RRDR), codons: S531L, D516V were highly mutated with frequencies of (21.73%, 17.39%) respectively. Outside the RRDR, there were nine different types of mutations, and M479L was the most prevalent one. Out of 23 RIF resistant isolates, seven isolates (30.43%) carried mutations in the rpoA gene, and twelve isolates (52.17%) harbored a mutation in rpoC. Most of the mutations were identified for the first time in this study. The current study demonstrated that mutations in rpoB, rpoA, and rpoC contributed to RIF resistance in Mycobacterium tuberculosis and this new finding may be relevant to realize how compensatory mutations in the rpoA and rpoC genes restore the fitness cost caused by rifampin resistance-conferring mutations in rpoB.
This study is a numerical investigation of the performance of reinforced concrete (RC) columns after fire exposure. This study aims to investigate the effect of introducing lateral ties and using the RC jacket on improving post-fire behavior of these columns, the effect of the duration of the fire on ultimate load of columns. The analysis was performed through ABAQUS, a 3D – non-linear finite element program. 4 m tall lengthening square RC column with a cross- section of 0.4 m × 0.4 m was used as a test specimen. The RC column was reinforced by 4Ø28 mm longitudinal bars bonded by steel tie bars of Ø10 mm spaced at 400 mm. The firing temperature was increased to 60
Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e
... Show MoreAn experiment was carried out in the vegetables field of Horticulture Department / College of Agriculture / Baghdad University , for the three seasons : spring and Autumn of 2005 , and spring of 2007 , to study the type of gene action in some traits of vegetative and flowery growth in summer squash crosses (4 x 3 = cross 1 , 3 x 7 = cross 2 , 3 x 4 = cross 3 , 3 x 5 = cross 4 , 5 x 1 = cross 5 , 5 x 2 = cross 6). The study followed generation mean analysis method which included to each cross (P1 , P2 , F1 , F2 , Bc1P1 , Bc1P2) , and those populations obtained by hybridization during the first and second seasons. Experimental comparison was performed in the second (Two crosses only) and third seasons , (four crosses) by using RCBD with three
... Show MoreA simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi
... Show Morehas experienced a step-change since the inception of ambient mass spectrometry removed the requirement for samples to be investigated under vacuum conditions. Approaches based on surface– plasma interactions are especially promising, including PADI. Whilst the mechanisms involved in generating PADI spectra still need to be unravelled, PADI shows significant promise to become a valuable and versatile tool in the instrumental arsenal available to the surface analyst