This paper deals with defining Burr-XII, and how to obtain its p.d.f., and CDF, since this distribution is one of failure distribution which is compound distribution from two failure models which are Gamma model and weibull model. Some equipment may have many important parts and the probability distributions representing which may be of different types, so found that Burr by its different compound formulas is the best model to be studied, and estimated its parameter to compute the mean time to failure rate. Here Burr-XII rather than other models is consider because it is used to model a wide variety of phenomena including crop prices, household income, option market price distributions, risk and travel time. It has two shape-parameters (α, r) and one scale parameter (λ) which is considered known. So, this paper defines the p.d.f. and CDF and derives its Moments formula about origin, and also derive the Moments estimators of two shapes parameters (α, r) in addition to maximum likelihood estimators as well as percentile estimators, the scale parameter (λ) is not estimated (as it is considered known). The comparison between three methods is done through simulation procedure taking different sample size (n=30, 60, 90) and different sets of initial values for (α, r, λ).It is observed that the moment estimators are the best estimator with percentage (46%) ,(42%) respectively compared with other estimators.
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show MoreRadiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th
Criteria to be met in selecting the obtimal areas for generating alternative electric energy from wind
The development of information systems in recent years has contributed to various methods of gathering information to evaluate IS performance. The most common approach used to collect information is called the survey system. This method, however, suffers one major drawback. The decision makers consume considerable time to transform data from survey sheets to analytical programs. As such, this paper proposes a method called ‘survey algorithm based on R programming language’ or SABR, for data transformation from the survey sheets inside R environments by treating the arrangement of data as a relational format. R and Relational data format provide excellent opportunity to manage and analyse the accumulated data. Moreover, a survey syste
... Show MoreLiquid membrane electrodes for the determination iron(III) were constructed based on chloramphenicol sodium succinate and iron(III) CPSS-Fe(III) as ion pair complex, with four plasticizers Di-butyl phosphate (DBP); Di-butyl phthalate (DBPH); Di-octyl phthalate (DOP); Tri-butyl phosphate (TBP); in PVC matrix . These electrodes give Nernstian and sub-Nernstian slopes (19.79, 24.60, 16.01 and 13.82mV/decade) and linear ranges from (1x10-5-1x10-2 M, 1x10-5-1x10-2 M, 1x10-6-1x10-2 M and 1x10-5-1x10-2 M) respectively. The best electrode was based on DBP plasticizer which gave a slope 19.79 mV/decade, correlation coefficient 0.9999, detection limit of 9×10-6 M, lifetime 37 day displayed good stability and reproducibility and used to determine
... Show MoreThe current study is concerned with the analysis of spatial and temporal to death the elderly population in the city of Baghdad and at the level of administrative units Minor (districts and the areas) depending on the general population census of the province of Baghdad, data for 1997 and data from the Ministry of Health Department of Health and Vital Statistics for 2013.
The study showed differing age and quality of mortality rates at the level of administrative units of the study area, and notes the high mortality rates of elderly people of all age groups in 2013 compared to 1997, and this is due to security conditions after the USA occupation, and the accompanying conditions have affected the increase in mortality rates.