Nicotine was separated from eggplant and green pepper seeds (Solanaceous) by High Performance Liquid Chromatography (HPLC).The concentration of nicotine in the eggplant extract (0.871-0.877 μg/ml) was determined by injecting standard material with 0.5 and 1.5 μg/ml, while the concentrations of nicotine in green pepper extract (0.613-0.618 μg/ml) was determined when the standard material was injected with 0.5 and 1.5 μg/ml. The qualitative chemical data was calculated from derivations of the standard material. Nicotine concentration was measured qualitatively in both extracts through the calibration curve and method of the standard addition. This technique has high accuracy and compatibility, bringing the proportion of relative recovery percentage of nicotine extracted from eggplant seeds to 95.880-103.104% and relative error of -4.119-3.104%. Relative recovery percentage of nicotine extracted from green pepper seeds was 97.284 -103.518 % and relative error was -2.716-3.518%.
The research aims to; identify the management of conflict as perceived by secondary school managers toward the directors of directorates of education in wassat province, identify functional performance as perceived by secondary school managers toward the directors of directorates of education in wassat province. Besides, explore the relationship between Conflict management and functional performance among the directors of directorates of education in wassat province. A descriptive approach deemed more appropriate with study design. As a tool to collect the data of current research, the author used a questionnaire. Spss tools were used for data analysis
Removing Congo red (CR) is critical in wastewater treatment. We introduce a combination of electrocoagulation (EC) and electro-oxidation (EO) to address the elimination of CR. We also discuss the deposition of triple oxides (Cu–Mn–Ni) simultaneously on both anodic and cathodic graphite electrodes at constant current density. These electrodes efficiently worked as anodes in the EC-EO system. The EC-CO combination eliminated around 98 % of the CR dye and about 95 % of the Chemical Oxygen demand (COD), and similar results were obtained with the absence of NaCl. Thus, EC-EO is a promising technique to remove CR in an environmentally friendly pathway.
The catalytic cracking of three feeds of extract lubricating oil, that produced as a by-product from the process of furfural extraction of lubricating oil base stock in AL-Dura refinery at different operating condition, were carried out at a fixed bed laboratory reactor. The initial boiling point for these feeds was 140 ºC for sample (1), 86 ºC for sample (2) and 80 ºC for sample (3). The catalytic cracking processes were carried out at temperature range 325-400 ºC and initially at atmospheric pressure after 30 minutes over 9.88 % HY-zeolite catalyst load. The comparison between the conversion at different operating conditions of catalytic cracking processes indicates that a high yield was obtained at 375°C, according to gasoline pr
... Show More|
Declaration has become today has an important and active and influential role in the recipient public life، and are concentrated advertising on the creativity component manufacture to attract his attention toward what to be announced from a variety products، and is dominated by television commercials tempo and imagination، and display them a variety of ways catches the attention and an impressive simulates the their senses of hearing and sight، to influence in the receiver and the public paid for purchase. Through it crystallization the subject of our research on the importance of creativity in television advertising and effective for attracting the attention of the publi |
A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .
Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×
... Show MoreBackground This study establishes a mathematically consistent and computational framework for the simultaneous identification of two time-dependent coefficients in a one-dimensional second-order parabolic partial differential equation. The considered problem is governed by nonlocal initial, boundary, and integral overdetermination conditions. Methods The direct problem is solved using the Crank-Nicolson finite difference method (FDM), which ensures unconditional stability and second-order accuracy in both spatial and temporal discretizations. The corresponding inverse problem is reformulated as a nonlinear regularized least-squares optimization problem and efficiently solved used the MATLAB subroutine
... Show MoreA method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav
... Show More