The effects of temperature on an exotic aquatic snail Pomacea canaliculata (Lamarck, 1819) collected from the Shatt Al-Arab intertidal zone were investigated. A series of laboratory experiments were conducted during the summer period of 2017. Individuals of new born snails hatched in the laboratory from adult snails were collected from Shatt Al-Arab intertidal zone, and subjected to five fixed temperatures: 15, 25, 35, 40 and 45 Cº, after short term thermal acclimation. The heartbeats (HB) were counted at each temperature level. The results showed significant direct increase of HB from 15 Cº (19.8 HB/min) up to 25 Cº (76 HB/min) (P<0.05) as well as from 25 Cº to 35 Cº (93 HB/min). At 40 Cº the snail HB shows only slight insignificant increase (79 HB/ min). At 45 ºC the HB became irregular and showed negative thermo cardiac activity (HB dropped to 50.4/min). The minimum HB rate of 11/min was recorded at 15 Cº and the maximum value of 119 HB/min was recorded at 40 Cº. The study concluded that P. canaliculata can be highly stressed when exposed to extreme temperature experienced during the prolonged summer months and will no longer tolerate living in the intertidal zone of Shatt Al-Arab.
In this work, the possibility of utilizing osmosis phenomenon to produce energy as a type of the renewable energy using Thin Film Composite Ultra Low Pressure membrane TFC-ULP was studied. Where by forward osmosis water passes through the membrane toward the concentrated brine solution, this will lead to raise the head of the high brine solution. This developed static head may be used to produce energy. The aim of the present work is to study the static head developed and the flux on the high brine water solution side when using forward and reverse osmosis membranes for an initial concentration range from 35-300 g/l for each type of membrane used at room temperature and pressure conditions, and finally calculating the maximum possible po
... Show MoreContours extraction from two dimensional echocardiographic images has been a challenge in digital image processing. This is essentially due to the heavy noise, poor quality of these images and some artifacts like papillary muscles, intra-cavity structures as chordate, and valves that can interfere with the endocardial border tracking. In this paper, we will present a technique to extract the contours of heart boundaries from a sequence of echocardiographic images, where it started with pre-processing to reduce noise and produce better image quality. By pre-processing the images, the unclear edges are avoided, and we can get an accurate detection of both heart boundary and movement of heart valves.
Background: The COVID-19 infection is a more recent pandemic disease all over the world and studying the pulmonary findings on survivors of this disease has lately commenced.
Objective: We aimed to estimate the cumulative percentage of whole radiological resolution after 3 months from recovery and to define the residual chest CT findings and exploring the relevant affecting factors.
Subjects and Methods: Patients who had been previously diagnosed with COVID-19 pneumonia confirmed by RT-PCR test and had radiological evidence of pulmonary involvement by Chest CT during the acute illness were included in the present study. The radiol
... Show MoreThe phytoremediation technique has become very efficient for treating soil contaminated with heavy metals. In this study, a pot experiment was conducted where the Dodonaea plant (known as hops) was grown, and soil previously contaminated with metals (Zn, Ni, Cd) was added at concentrations 100, 50, 0 mg·kg-1 for Ni and Zn, and at concentrations of 0, 5, 10 mg·kg-1 for cadmium. Irrigation was done within the limits of the field capacity of the soil. Cadmium, nickel and zinc was estimated in the soil to find out the capacity of plants to the absorption of heavy and contaminated metals by using bioconcentration factors (BCFs), bioaccumulation coefficient (BAC) and translocation factor (TF). Additionally, BCF values of both Ni and Zn were l
... Show MoreThe ground state proton, neutron, and matter density distributions and corresponding root-mean-square (rms) of P19PC exotic nucleus are studied in terms of two-frequency shell model (TFSM) approach. The single-particle wave functions of harmonic-oscillator (HO) potential are used with two different oscillator parameters bRcoreR and bRhaloR. According to this model, the core nucleons of P18PC nucleus are assumed to move in the model space of spsdpf. The shell model calculations are carried out for core nucleons with w)20(+ truncations using the realistic WBPinteraction. The outer (halo) neutron in P19PC is assumed to move in the pure 2sR1/2R-orbit. The halo structure in P19PC is confirmed with 2sR1/2R-dominant configuration.Elastic electr
... Show MoreA simulation study of using 2D tomography to reconstruction a 3D object is presented. The 2D Radon transform is used to create a 2D projection for each slice of the 3D object at different heights. The 2D back-projection and the Fourier slice theorem methods are used to reconstruction each 2D projection slice of the 3D object. The results showed the ability of the Fourier slice theorem method to reconstruct the general shape of the body with its internal structure, unlike the 2D Radon method, which was able to reconstruct the general shape of the body only because of the blurring artefact, Beside that the Fourier slice theorem could not remove all blurring artefact, therefore, this research, suggested the threshold technique to eliminate the
... Show MoreT he article deals with the linguistic, cultural, sociolinguistic, functional and stylistic characteristics of the translation of gluttonic discourse text structures within the framework of the Arabic-Russian combination, as well as with the difficulties encountered in interpretation and translation and related to different conditions under which speech is generated in Arabic and Russian-speaking areas.
Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.
... Show More