Preferred Language
Articles
/
bsj-2615
Comparing Study of The Stability and spectral properties vibrations for some Tellurium (IV) compounds containing cycloctadienyl group by Quantum Mechanical Calculations
...Show More Authors

Density Functional Theory (DFT) with B3LYP hybrid exchange-correlation functional and 3-21G basis set and semi-empirical methods (PM3) were used to calculate the energies (total energy, binding energy (Eb), molecular orbital energy (EHOMO-ELUMO), heat of formation (?Hf)) and vibrational spectra for some Tellurium (IV) compounds containing cycloctadienyl group which can use as ligands with some transition metals or essential metals of periodic table at optimized geometrical structures.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Iraqi Journal Of Science
Some Properties of Algebraically Paranormal Operator
...Show More Authors

Through this study, the following has been proven, if  is an algebraically paranormal operator acting on separable Hilbert space, then  satisfies the ( ) property and  is also satisfies the ( ) property for all . These results are also achieved for  ( ) property.    In addition, we prove that for a polaroid operator with finite ascent then after the property ( ) holds for  for all.

Crossref (1)
Scopus Crossref
Publication Date
Sun Oct 29 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment the Relation between Breast Cancer and Blood Group
...Show More Authors

Objectives: To assess the relation between breast cancer & blood groups, identify the importance of women
age group and the relation of age with breast cancer.
Methodology: The study was performed on (115) women who were diagnosed with breast cancer in different
stages of disease and different ages. Blood samples were taken from them to demonstrate their blood groups and
(20) fresh tumor tissue samples were obtained; the tumor tissue used as a source of lectin for hemagglutinate
with erythrocyte of different blood groups. The study conducted at Baghdad Teaching Hospital and Radiation &
Nuclear Medicine Hospital from January, 2007 through June 2007.
Results: The study shows that the highest percentage of women

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 13 2019
Journal Name
Al-khwarizmi Engineering Journal
Investigation Microwave Furnace Effects on Mechanical Properties and Fatigue Life of AA 7075-T73 with Dry and Acid Treatments
...Show More Authors

Microwave heating is caused by the ability of the materials to absorb microwave energy and convert it to heat. The aim of this study is to know the difference that will occur when heat treating the high strength aluminum alloys AA7075-T73 in a microwave furnace within different mediums (dry and acidic solution) at different times (30 and 60) minutes, on mechanical properties and fatigue life. The experimental results of microwave furnace heat energy showed that there were variations in the mechanical properties (ultimate stress, yielding stress, fatigue strength, fatigue life and hardness) with the variation in mediums and duration times when compared with samples without treatment. The ultimate stress, yielding stress and fatigue streng

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 04 2024
Journal Name
Iraqi Journal Of Applied Physics
Experimental Investigation on Mechanical and Physical Properties of Hybrid Plastic/Wood Composites as Echo-friendly Structural and Decorative Materials
...Show More Authors

This study focuses on producing wood-plastic composites using unsaturated polyester resin reinforced with Pistacia vera shell particles and wood industry waste powder. Composites with reinforcement ratios of 0%, 20%, 30%, and 40% were prepared and tested for thermal conductivity, impact strength, hardness, and compressive strength. The results revealed that thermal conductivity increases with reinforcement, while maintaining good thermal insulation, reaching a peak value of 0.633453 W/m·K. Hardness decreased with increased reinforcement, reaching a minimum nominal hardness value of 0.9479. Meanwhile, impact strength and compressive strength improved, with peak values of 14.103 k/m² and 57.3864568 MPa, respectively. The main aim is to manu

... Show More
Publication Date
Tue Dec 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Spectral Study of Pt (II), Cr (II) Polymeric Complexes of the Ligand N- Crotonyl -2- Hydroxy-Phenylazomethine
...Show More Authors

 The polymeric complexes were obtained from the reaction of polymeric Schiff base.N-crotonyl-2-hydroxyphenylazomethine (HL), with divalent metals Pt (II), Cr (II). The modes of bonding and overall geometry of the complexes were determine through spectroscopic methods and compared with that reported from analogous monomeric ligand. This study revealed square planer geometry around the metal center for [Pt(L)Cl] and distorted octahedral geometry for Cr complex [Cr(L)Cl(H2O)2].

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Evaluation of the optical properties for thick films of epoxy-diamond paste blend prepared by the casting method
...Show More Authors

View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Engineering
Entransy dissipation of Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
...Show More Authors

Shell-and-double concentric tube heat exchanger is one of the new designs that enhance the heat transfer process. Entransy dissipation is a recent development that incorporates thermodynamics in the design and optimization of heat exchangers. In this paper the concept of entransy dissipation is related to the shell-and-double concentric tube heat exchanger for the first time, where the experiments were conducted using hot oil with temperature of 80, 100 and 120°C, flow rate of cold water was 0.667, 1, and 1.334 kg/m3 respectively and the temperature of inlet cold water was 20°C. The entransy dissipation rate due to heat transfer and to fluid friction or pressure drop was studied.

 

View Publication Preview PDF
Publication Date
Tue Jan 05 2021
Journal Name
Kufa Journal Of Engineering
IMPROVEMENT OF MARSHALL PROPERTIES FOR HOT MIX ASPHALT BY USING CERAMIC FIBER
...Show More Authors

Crossref
Publication Date
Wed Sep 20 2023
Journal Name
International Journal Of Dentistry
Improving Surface Properties of PEEK for Dental Applications by Using Piranha Solution
...Show More Authors

Background. “Polyetheretherketone (PEEK)” is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods. PEEK disks of 10 mm diameter and 2 mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon May 23 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Iraqi Pharmaceutical Formula for Clonazepam Oral Drop 2.5 mg/ ml to Treat Seizure Epilepsy in Infants and Children with its Stability Study.: Iraqi Pharmaceutical Formula for Clonazepam Oral Drop 2.5 mg/ ml to Treat Seizure Epilepsy in Infants and Children with its Stability Study.
...Show More Authors

This work has been carried out to develop national drug product contains 2.5mg/ml clonazepam as oral drop; it is used for the treatment of epilepsy in infants and children.
Several formulations were prepared using oral drop base, flavor, buffer, sweeteners and preservatives. Selection of best formula relied solely on physic-chemical testing of samples.
Stability study was conducted on the product for six months at different temperatures to determine the expiration date and the best storage conditions.
From the study we obtained an oral drop of good clear solution. The expiry date calculated to be not less than 2 years.

View Publication Preview PDF