The work in this paper focuses on the system quality of direct and coherent communication system for two computers. A system quality is represented by Signal to Noise ratio (SNR) and Bit Error Rate (BER). First part of the work includes implementation of direct optical fiber communication system and measure the system quality .The second part of the work include implementation both the( homodyne and heterodyne)coherent optical fiber communication system and measure the system quality . Laser diode 1310 nm wavelength with its drive circuit used in the transmitter circuit . A single mode of 62.11 km optical fiber is selected as transmission medium . A PIN photo detector is used in the receiver circuit. The optical D-coupler was used to combine the optical signal that come from transmitter laser source with optical signal of laser local oscillator at 1310/1550 nm to obtain coherent detection . Results show that for direct detection the SNR and the BER (28.5 dB, 9.64x10-8,) respectively, while for homodyne and heterodyne coherent detection , the SNR(94.36,97.71)dB and the BER are (1.32x10-22,2.43x10-23) at maximum optical fiber length at 62.11 km. Results show that the homodyne and heterodyne detection are better than direct detection because the large output SNR and low BER of the received signal.
Over the years, the field of Medical Imagology has gained considerable importance. The number of neuroimaging studies conducted using functional magnetic resonance imaging (fMRI) has been exploding in recent years. fMRI survey gives to rise to large amounts of noisy data with a complex spatiotemporal correlation structure. Statistics play great role in clarifying the features of the data and gain results that can be used and explain by neuroscientists. Several types of artifacts can happen through a functional magnetic resonance imaging (fMRI) scanner Because of software or hardware problems, physical limitation or human physiologic phenomenon. Several of them can negatively affect di
In this work, the plasma parameters (electron temperature and
electron density) were determined by optical emission spectroscopy
(OES) produced by the RF magnetron Zn plasma produced by
oxygen and argon at different working pressure. The spectrum was
recorded by spectrometer supplied with CCD camera, computer and
NIST standard of neutral and ionic lines of Zn, argon and oxygen.
The effects of pressure on plasma parameters were studied and a
comparison between the two gasses was made.
A new results for fusion reactivity and slowing-down energy distribution functions for controlled thermonuclear fusion reactions of the hydrogen isotopes are achieved to reach promising results in calculating the factors that covered the design and construction of a given fusion system or reactor. They are strongly depending upon their operating fuels, the reaction rate, which in turn, reflects the physical behavior of all other parameters characterization of the system design
In the present investigation two different types of fiber reinforced polymer composites were prepared by hand lay-up method using three different parameters (curing temperature, pressing load and fiber volume fraction). These composites were prepared from the polyester resin as the matrix material reinforced with glass fibers as first group of samples and mat Kevlar fibers as the second group, both with different volume fractions (4%, 8%, and 12%) of fibers. They were then tested by tensile strength and impact strength. The main objective in this study is to use Taguchi method for predicting the better parameters that give the better tensile and impact strength to the composites, and then preparing composites at
... Show MoreIn this paper the full stable Banach gamma-algebra modules, fully stable Banach gamma-algebra modules relative to ideal are introduced. Some properties and characterizations of these classes of full stability are studied.
Infrastructure, especially wastewater projects, plays an important role in the life of residential communities. Due to the increasing population growth, there is also a significant increase in residential and commercial facilities. This research aims to develop two models for predicting the cost and time of wastewater projects according to independent variables affecting them. These variables have been determined through a questionnaire distributed to 20 projects under construction in Al-Kut City/ Wasit Governorate/Iraq. The researcher used artificial neural network technology to develop the models. The results showed that the coefficient of correlation R between actual and predicted values were 99.4% and 99 %, MAPE was
... Show MoreThe research aims to design a narrow-band frequency drive amplifier (1.5GHz -1.6GHz), which is used to boost the transmitter amplifier's input signal or amplify the GPS, GlONASS signals at the L1 band.
The Power Amplifier printed circuit board (PCB) prototype was designed using InGaP HBT homogeneous technology transistor and GaAs Heterojunction Bipolar Transistor (HBT) transistor. Two models have been compared; one of the models gave 16dB gain, and the other gave 23dB when using an input power signal (-15dBm). The PCB consumes 2.4W of power and has a physical dimension of 11 x 4 cm.
The study aimed to compare the expression of miR-126-3p and miR-423-5p in patients and normal subjects, and correlate their expression with response to induction therapy. Circulating miR-126-3p and miR-423-5p were measured in the plasma of 43 adult AML patients and 35 age- and sex-matched controls by real time PCR. The foldchange in differential expression for each gene was calculated using the comparative cycle threshold (CT) method (also known as the 2−CT method). For statistical purposes, the fold change was calculated using DDCT (or 2–∆∆Ct) method to find the relative expression of miRNAs. The expression fold change of miR-126-3p was 1.73-fold increase in patients than controls (p= 0.010). The expression fold change of miR-423-5
... Show MoreDue to severe scouring, many bridges failed worldwide. Therefore, the safety of the existing bridge (after contrition) mainly depends on the continuous monitoring of local scour at the substructure. However, the bridge's safety before construction mainly depends on the consideration of local scour estimation at the bridge substructure. Estimating the local scour at the bridge piers is usually done using the available formulae. Almost all the formulae used in estimating local scour at the bridge piers were derived from laboratory data. It is essential to test the performance of proposed local scour formulae using field data. In this study, the performance of selected bridge scours estimation formulae was validated and sta
... Show More