The aim of this research is to determine the uranium concentration in soil and water samples taken from different locations from the middle and south of Iraq using fission fragments track registration. Twelve samples of soil and water were taken from middle and South of Iraq. The nuclear reaction used as a source of nuclear fission fragments is U-235 (n.f) obtained by bombardment U-235with thermal neutrons from (Am-Be) neutron source with flux (5X103 n.cm-2.s-1). The concentration values were calculated by a comparison with standard samples recommended by IAEA.The results of the measurements show that the uranium concentration in soil samples were in Thekar (16.38 ppm), AL-Basra (16.1ppm) and (0.78 ppm) in Baghdad, from the results which show that this governorate were contaminated with depleted uranium after the Wars against Iraq . The uranium concentration in the water samples of Tigers river were in AL-Qurna (8.85 ?g/l) and in AL-Suwera (4.72 ?g/l).
Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 were used for absolute dose measurement in Equinox accelerator. A comparison of dose measurement by two different IAEA protocols TRS-277 and TRS-398 has been studied. Analyzing TRS-398, a common shaped empirical formula was developed for the four Co-60 units of four Medical Colleges in Bangladesh with fitting parameters. It was found that an average discrepancy in the determination of absorbed dose in water among the two different protocols TRS-277 and TRS-398 were 1
... Show MoreOne hundred of dialysis patients' mean age ( 51.18±8.28) years and one hundred healthy control group , where carried out from different hospitals of Baghdad city , during the period between November /2012 until March/2013. Blood samples were collected before dialyzing for estimation the concentration of urea, creatinine, uric acid, random blood sugar , calcium and cholesterol by enzymatic method detected spectrophotometerically.
The aim of this study is to determine concentration of urea, creatinine, uric acid, RBS , calcium and cholesterol in hemodialysis patients in Baghdad . The results showed that there were highly significant increases (P<0.01) in the mean of creatinine ,
... Show MoreIn this research the a-As flims have been prepared by thermal evaporation with thickness 250 nm and rata of deposition r_d(1.04nm/sec) as function to annealing temperature (373 and 473K), from XRD analysis we can see that the degree of crystalline increase with T_a, and I-V characteristic for dark and illumination shows that forward bias current varieties approximately exponentially with voltage bias. Also we found that the quality factor and saturation current dependence on annealing temperatures.
In this research the a-As flims have been prepared by thermal evaporation with thickness 250 nm and rata of deposition (1.04nm/sec) as function to annealing temperature (373 and 373K), from XRD analysis we can see that the degree of crystalline increase with , and I-V characteristic for dark and illumination shows that forward bias current varieties approximately exponentially with voltage bias. Also we found that the quality factor and saturation current dependence on annealing temperatures.
Purpose: To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design: Descriptive observational. Place and Duration of Study: Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods: A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results: Mean age was 28.54 ± 6.6 years, me
... Show MoreThirty-two soil samples were collected from the study area in October 2020 for geochemical and pollutants investigation of Shwan Sub-basin soil. All soil samples were analysed for different geochemical analyses. The analysis results revealed that the pH values in soil samples ranged from 7.12 to 7.56 with a mean of 7.327. According to the pH values detected in the soil samples, the soil is classified as neutral soil. The electrical conductivity ranged from 0.92 mmhos/cm to 7.8 mmhos/cm with a mean of 1.53 mmhos/cm. Thus, according to the detected electrical conductivity values, the soil was classified as non-saline to slightly saline. The organic matter ranged from 1.14% to 1.45% with a mean value of 1.326 %, while total organic
... Show MoreEight soil samples were selected around Najaf governorate at depth levels 40-50 cm. X-Ray Fluorescence (XRF) was used to determine the concentrations of major and trace elements. Liner and mass attenuation coefï¬cient (µ, µÏ) have been determined at gamma energies (662, 1172,1332) keV using NaI (Tl) detector. The range of linear attenuation coefficients for calculated samples were (0.553-1.163) cm-1, (0.122-0.178) cm-1 and (0.049-0.105) cm-1 at (662, 1172,1332) keV respectively. The range of mass attenuation coefficients obtained (0.39-0.76) cm2/gm, (0.087-0.117) cm2/gm and (0.0336-0.074) cm2/gm at (662, 1172,1332) keV respectively. The result
... Show MoreThis paper displays a survey about the laboratory routine core analysis study on ten sandstone core samples taken from Zubair Reservoir/West Quarna Oil Field. The Petrophysical properties of rock as porosity, permeability, grain's size, roundness and sorting, type of mineral and volumes of shales inside the samples were tested by many apparatus in the Petroleum Technology Department/ University of Technology such as OFITE BLP-530 Gas Porosimeter, PERG-200TM Gas Permeameter and liquid Permeameter, GeoSpec2 apparatus (NMR method), Scanning Electron Microscopy (SEM) and OFITE Spectral Gamma Ray Logger apparatus. By comparing all the results of porosity and permeability measured by these instruments, it is clear a significant vari
... Show More