Let R be a 2-torision free prime ring and ?, ?? Aut(R). Furthermore, G: R×R?R is a symmetric generalized (?, ?)-Biderivation associated with a nonzero (?, ?)-Biderivation D. In this paper some certain identities are presented satisfying by the traces of G and D on an ideal of R which forces R to be commutative
Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy (Heavy
Metals), including toxic in the air, with different concentrations in the air depending on the
nature of the area, for example be in rural areas is lower than in cities or industrial areas as
measured parts million (ppm ) or parts per billion (ppb). Some of these important elements in
the physiological processes and enzymatic organisms but become toxic and Qatlhand-increase
Tercisahaan the permissible limits Bhave nature ,The air contaminant co
The combination of high protein content and a soft seed coat makes the wheat-rye hybrid Triticale (Triticosecale) vulnerable to attack by rice weevils. Drying triticale grain to moisture contents safe for storage can prevent infestation by rice weevils, but if grain is being stored for seed, high drying temperatures can affect seed germination. Grain can be effectively dried at low temperatures, but low-temperature drying is difficult in hot, humid regions such as the Gulf Coast. This study nvestigated the effects of drying temperatures from 35°C to 45°C on triticale seed germination and found no statistical differences between the germination rates of the seed at any of the drying temperatures and the germination rates of controls. Final
... Show MoreA variety of new phenolic Schiff bases derivatives have been synthesized starting from Terephthaladehyde compound, all proposed structures were supported by FTIR, 1H-NMR, 13C-NMR, Elemental analysis, some derivatives evaluated by Thermal analysis (TGA).
Biaxial hollow slab is a reinforced concrete slab system with a grid of internal spherical voids included to reduce the self-weight. This paper presents an experimental study of behavior of one-way prestressed concrete bubbled slabs. Twelve full-scale one-way concrete slabs of (3000mm) length with rectangular cross-sectional area of (460mm) width and (150mm) depth. Different parameters like type of specimen (solid or bubbled slabs), type of reinforcement (normal or prestress), range of PPR and diameter of plastic spheres (100 or 120mm) are considered. Due to the using of prestressing force in bubbled slabs (with ratio of plastic sphere diameter D to slab thickness H, D/H=0.67), the specimens showed an increase in ultimat
... Show MoreThe research aims to study some of the human characteristics of the state of Singapore to know the impact of these characteristics on the strength of the state, its development and. The research included two aspects, theoretical and analytical, using the descriptive analytical method, force analysis method, as well as the historical method. The data was analyzed according to mathematical equations, including the size of the country's population, the extraction of the population growth rate and the concept of age structure, where some indicators related to this concept have been explained. The researcher reached a set of results, the most important of which were: that the population size of the state of Singapore in the period between (19
... Show MoreScams remain among top cybercrime incidents happening around the world. Individuals with high susceptibility to persuasion are considered as risk-takers and prone to be scam victims. Unfortunately, limited number of research is done to investigate the relationship between appeal techniques and individuals' personality thus hindering a proper and effective campaigns that could help to raise awareness against scam. In this study, the impact of fear and rational appeal were examined as well as to identify suitable approach for individuals with high susceptibility to persuasion. To evaluate the approach, pretest and posttest surveys with 3 separate controlled laboratory experiments were conducted. This study found that rational appeal treatm
... Show MoreThermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl