Preferred Language
Articles
/
bsj-2138
Comparison Between Conventional and Microwave Methods For Extraction Pectin and Degree of Esterification from Orange (Citrus sinesis) and Grapefruit (Citrus paradisi) Peels
...Show More Authors

In this study Microwave and conventional methods have been used to extract and estimate pectin and its degree of esterification from dried grapefruit and orange peels. Acidified solution water with nitric acid in pH (1.5) was used. In conventional method, different temperature degrees for extraction pectin from grape fruit and orange(85 ,90 , 95 and 100?C) for 1 h were used The results showed grapefruit peels contained 12.82, 17.05, 18.47, 15.89% respectively, while the corresponding values were 5.96, 6.74, 7.41 and 8.00 %, respectively in orange peels. In microwave method, times were 90, 100, 110 and 120 seconds. Grapefruit peels contain 13.86, 16.57, 18.69, and 17.87%, respectively, while the corresponding values were of 6.53, 6.68, 7.28 and 9.05 %, respectively in orange peels. The degree of esterification increased gradually in both methods. The maximum values were of 69.7% in orange and of 67% in grapefruit at 95 °C in conventional method, while microwave method the values gave 68.8% and 66.6% for orange and grape fruit pectin at 110 sec, respectively .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Bayes and Non-Bayes Estimation Methods for the Parameter of Maxwell-Boltzmann Distribution
...Show More Authors

In this paper, point estimation for parameter ? of Maxwell-Boltzmann distribution has been investigated by using simulation technique, to estimate the parameter by two sections methods; the first section includes Non-Bayesian estimation methods, such as (Maximum Likelihood estimator method, and Moment estimator method), while the second section includes standard Bayesian estimation method, using two different priors (Inverse Chi-Square and Jeffrey) such as (standard Bayes estimator, and Bayes estimator based on Jeffrey's prior). Comparisons among these methods were made by employing mean square error measure. Simulation technique for different sample sizes has been used to compare between these methods.

View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Comparative Evaluation of Roundabout Capacities Methods for Single-lane and Multi-lane Roundabout
...Show More Authors

A roundabout is a highway engineering concept meant to calm traffic, increase safety, reduce stop-and-go travel, reduce accidents and congestion, and decrease traffic delays. It is circular and facilitates one-way traffic flow around a central point. The first part of this study evaluated the principles and methods used to compare the capacity methods of roundabouts with different traffic conditions and geometric configurations. These methods include gap acceptance, empirical, and simulation software methods. Previous studies mentioned in this research used various methods and other new models developed by several researchers. However, this paper's main aim is to compare different roundabout capacity models for acceptabl

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Batch and flow injection spectrophotometric methods for determination of Ceftazidime in pharmaceutical formulations
...Show More Authors

It is generally accepted that there are two spectrophotometric techniques for quantifying ceftazidime (CFT) in bulk medications and pharmaceutical formulations.  The methods  are described as simple, sensitive, selective, accurate and efficient techniques. The first method used an alkaline medium to convert ceftazidime to its diazonium salt, which is then combined with the 1-Naphthol (1-NPT) and 2-Naphthol (2-NPT) reagents. The azo dye that was produced brown  and red in color with absorption intensities of ƛmax 585 and 545nm respectively. Beer's law was followed in terms of concentration ranging from  (3-40) µg .ml-1 For (CFT-1-NPT) and (CFT-2-NPT), the detection limits were 1.0096 and 0.8017 µg.ml-1, respec

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Fri Oct 01 2021
Monitoring and controlling the speed and direction of a DC motor through FPGA and comparison of FPGA for speed and performance optimization
...Show More Authors

<span lang="EN-US">We are living in the 21<sup>st</sup> century, an era of acquiring necessity in one click. As we, all know that technology is continuously reviving to stay ahead of advancements taking place in this world of making things easier for mankind. Technology has been putting his part in introducing different projects as we have used the field programmable gate arrays (FPGAs) development board of low cost and programmable logic done by the new evolvable cyclone software is optimized for specific energy based on Altera Cyclone II (EP2C5T144) through which we can control the speed of any electronic device or any Motor Control IP product targeted for the fan and pump. Altera Cyclone FPGAs’ is a board thro

... Show More
Scopus (15)
Crossref (6)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
2019 First International Conference Of Computer And Applied Sciences (cas)
A Comparison for Some of the estimation methods of the Parallel Stress-Strength model In the case of Inverse Rayleigh Distribution
...Show More Authors

View Publication
Scopus (10)
Crossref (3)
Scopus Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Chemical Data Collections
Removal of diclofenac from aqueous solution on apricot seeds activated carbon synthesized by pyro carbonic acid microwave
...Show More Authors

Pharmaceuticals have been widely remaining contaminants in wastewater, and diclofenac is the most common pharmaceutical pollutant. Therefore, the removal of diclofenac from aqueous solutions using activated carbon produced by pyrocarbonic acid and microwaves was investigated in this research. Apricot seed powder and pyrophosphoric acid (45 wt%) were selected as raw material and activator respectively, and microwave irradiation technique was used to prepare the activated carbon. The raw material was impregnated in pyrophosphoric acid at 80◦C with an impregnation ratio of 1: 3 (apricot seeds to phosphoric acid), the impregnation time was 4 h, whereas the power of the microwave was 700 watts with a radiation time of 20 min. A series o

... Show More
Crossref (16)
Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of some robust methods to estimate parameters of partial least squares regression (PLSR)
...Show More Authors

   The technology of reducing dimensions and choosing variables are very important topics in statistical analysis to multivariate. When two or more of the predictor variables are linked in the complete or incomplete regression relationships, a problem of multicollinearity are occurred which consist of the breach of one basic assumptions of the ordinary least squares method with incorrect estimates results.

 There are several methods proposed to address this problem, including the partial least squares (PLS), used to reduce dimensional regression analysis. By using linear transformations that convert a set of variables associated with a high link to a set of new independent variables and unr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
International Journal Of Physics And Research (ijpr)
CALCULATIONS OF MOLTIPOLE MIXING RATIOS FOR GAMMA TRANSITIONS OF Yb POPULATED FROM Yb REACTION USING -RATIO, CONSTANT STATISTICAL TENSOR AND LEAST SQUARES FITTING METHODS
...Show More Authors

The - mixing ratios of -transitions from levels in populated in the reactions are calculated in present work using - ratio, constant statisticalTensor and least squares fitting methods The results obtained are in general, in good agreement or consistent, within the associated uncertainties, with these reported in Ref.[9],the discrepancies that occurs are due to inaccuracy existing in the experimental data The results obtained in the present work confirm the –method for mixed transitions better than that for pure transition because this method depends only on the experimental data where the second method depends on the pure or those considered to be pure -transitions, the same results occur in – method

Publication Date
Mon Oct 03 2022
Journal Name
Egyptian Journal Of Chemistry
Improving Biogas Production from Rice Husk Waste by Mixing with Pomegranate peels Waste by using Anaerobic Digestion
...Show More Authors

Biogas is one of the most important sources of renewable energy and is considered as an environment friendly energy source. The major goal of this research is to see if rice husk (Rh) waste and pomegranate peels (PP) waste are suitable for anaerobic digestion and what effect NaOH pre-treatment has on biogas generation. Rice husk and pomegranate peels were tested in anaerobic digestion under patch anaerobic conditions as separate wastes as well as blended together in equal proportions. The cumulative biogas output for the blank test (no pretreatment) was 1923 and 2526 ml, respectively using a single rice husk (Rh) and pomegranate peel (PP) substrates. The 50% rice husk digestion and 50% of pomegranate peels for blank test gave the result 224

... Show More
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Oil from Eucalyptus Camadulensis Using Water Distillation Method
...Show More Authors

This work was conducted to study the extraction of eucalyptus oil from natural plants (Eucalyptus camaldulensis leaves) using water distillation method by Clevenger apparatus. The effects of main operating parameters were studied: time to reach equilibrium, temperature (70 to100°C), solvent to solid ratio (4:1 to 8:1 (v/w)), agitation speed (0 to 900 rpm), and particle size (0.5 to 2.5 cm) of the fresh leaves, to find the best processing conditions for achieving maximum oil yield. The results showed that the agitation speed of 900 rpm, temperature 100° C, with solvent to solid ratio 5:1 (v/w) of particle size 0.5 cm for 160 minute give the highest percentage of oil (46.25 wt.%). The extracted oil was examined by HPLC.

View Publication Preview PDF