Preferred Language
Articles
/
bsj-2128
Energy Calculation for Excited Lithium Atom in Position Space
...Show More Authors

The energy expectation values for Li and Li-like ions ( , and ) have been calculated and examined within the ground state and the excited state in position space. The partitioning technique of Hartree-Fock (H-F) has been used for existing wave functions.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 04 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Evaluation of the Relationship between Osteoporosis and Body Fat Mass of the Upper and Lower Extremities by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Using dual-energy X-ray absorptiometry, body fat mass has been determined. The assessment of body fat mass was conducted utilizing dual-energy X-ray absorptiometry analysis of the pelvis and vertebral column. While it is acknowledged that osteoporosis can impact both body fat mass and bone mineral density, the particulars of this relationship currently remain uncertain. Objective: The aim of the present investigation is to assess gender differences in the effects of osteoporosis on the body fat mass of the upper and lower extremities. Method: 170 individuals participated (85 males and 85 females) in this study. Patients who presented with bone discomfort consisted of 40 males and 40 females. In addition, 90 apparently he

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Ssrn Electronic Journal
Developing a Predictive Model and Multi-Objective Optimization of a Photovoltaic/Thermal System Based on Energy and Exergy Analysis Using Response Surface Methodology
...Show More Authors

View Publication
Crossref (4)
Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Study of the Effect of Diabetes Mellitus I on Bone Mineral Density of Upper and Lower Limbs by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Bone mineral density (BMD) has been assessed using Dual-Energy X-ray absorptiometry (DEXA). This procedure is considered to be of vital importance in assessing the general condition of individuals concerning their skeletal mineralization. BMD is measured according to the results of the DEXA examination of the vertebral column and pelvis. Although diabetes mellitus (D.M.)is known to affect BMD, the information regarding this relationship is not currently particularly clear. Objective: This study concentrates on the point that the assessment of BMD for the vertebral column is insuffi-cient to give a realistic and correct picture of the mineralization of the remaining part of the skeleton. Besides, this study elicited a gen

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Mon May 20 2024
Journal Name
Iraqi Journal Of Applied Physics
Effect of Thermal Neutron Radiation Dose on Density of Local and Extended Energy States in Se<inf>55</inf>S<inf>20</inf>Sb<inf>15</inf>Sn<inf>10</inf> Alloy
...Show More Authors

Four samples of the Se55S20Sb15Sn10 alloy were prepared using the melting point method. Samples B, C and D were irradiated with (6.04×1010, 12.08×1010 and 18.12×1010 (n.cm-2s -1 ) of thermal neutron beam from a neutron source (241Am-9Be) respectively, while sample A was left not irradiated. The electrical properties were assessed both before and after the radiation. All irradiated and non-irradiated samples show three conduction mechanisms, at low temperatures, electrical conductivity is achieved by electron hopping between local states near the Fermi level. At intermediate temperatures, conduction occurs by the jumping of electrons between local states at band tails. At high temperatures, electrons transfer between extended stat

... Show More
View Publication Preview PDF
Scopus (3)
Scopus
Publication Date
Thu Apr 27 2023
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Evaluation of the Effect of Type II Diabetes mellitus on Bone Mineral Density of Upper and Lower Limbs by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Bone mineral density has been assessed using Dual-Energy X-Ray Absorptiometry. Bone mineral density is measured according to the results of the Dual-Energy X-Ray Absorptiometry examination of the vertebral column and pelvis. Although diabetes mellitus type II (DM) is known to affect bone mineral density, at the present time this particular relationship is not clear. Objective: The aim of current study was to evaluate the effects of type II diabetes mellitus on bone mineral density of the upper and lower limbs as well as gender differences. Patients and Methods: This study involved 165 patients complaining of bone pain (85 males and 80 females), 85 patients of who suffered from diabetes, involving both genders. In addition,

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Analysis of X-ray diffraction lines profile of Tio2 nanoparticles to determine the energy per unit volume and stress by using Halder-Wagner method
...Show More Authors

In this study, the Halder-Wagner method was used for an analysisX-ray lines of Tio2 nanoparticles. Where the software was used to calculate the FWHM and integral breath (β) to calculate the area under the curve for each of the lines of diffraction. After that, the general equation of the halder- Wagner method is applied to calculate the volume (D), strain (ε), stress (σ), and energy per unit(u). Volume (β). Where the value of the crystal volume was equal to (0.16149870 nm) and the strain was equal to (1.044126), stress (181.678 N / m2), and energy per unit volume (94.8474 J m-3).The results obtained from these methods were then compared with those obtained from each of the new paradigm of the HalderWagner method, the Shearer developm

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Linear Increasing in Radial Electronic Density Distribution for K and L Shells throughout Some Be-Like Ions
...Show More Authors

Maximum values of one particle radial electronic density distribution has been calculated by using Hartree-Fock (HF)wave function with data published by[A. Sarsa et al. Atomic Data and Nuclear Data Tables 88 (2004) 163–202] for K and L shells for some Be-like ions. The Results confirm that there is a linear behavior restricted the increasing of maximum points of one particle radial electronic density distribution for K and L shells throughout some Be-like ions. This linear behavior can be described by using the nth term formula of arithmetic sequence, that can be used to calculate the maximum radial electronic density distribution for any ion within Be like ions for Z<20.

View Publication Preview PDF
Crossref
Publication Date
Fri Aug 19 2022
Journal Name
International Journal Of Health Sciences
A study of the mechanical and electrical activities of the heart and their relationship to the phosphagenic and lactic energy systems of young basketball players
...Show More Authors

It was found that there was a significant correlation between all tests of the mechanical and electrical activity of the heart (systolic force FC, stroke volume SV, end-diastolic volume, EF volume, and left ventricular volume during diastole LVDD) with the test of the oxygen-phosphating energy system (Markaria). - As safe (Margaria-Kalamen( It was found that there is a significant correlation between all tests of the mechanical and electrical activity of the heart (myocardial systolic force FC, stroke volume SV, end-diastolic volume EDV, and the percentage of heart pumpingEF blood, and left ventricular volume during diastole (LVDD) with the Lactational Oxygen Energy System Test (Wingate Test 30 Second(

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
CFIA-Turbidimetric and Photometric Determination of Vitamin B9 (Folic acid) Using LEDs as a Source of Irradiation and Two Solar Cells as an Energy Transducer
...Show More Authors

A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Rotation Effect in Morse Potential For K2 Molecule
...Show More Authors

The rotation effect upon Morse potential had been studied and the values of the effective potential in potential curves had been calculated for electronic states (X2?+g , B ?u ) K2 molecule. The calculation had been computed for rotational quantum number (J = 5). Also, drawing potential curves for these systems had been done using Herzberg and Gaydon equations. It was found that the values of the dissociation energy which resulting from using Herzberg equation greater than that of Gaydon equation. Besides, it was found that the rotation effect for (X and B) electronic states in Morse potential is very small and in this case may negligible.

View Publication Preview PDF
Crossref