Preferred Language
Articles
/
bsj-1431
A Comparison of the Methods for Estimation of Reliability Function for Burr-XII Distribution by Using Simulation.
...Show More Authors

This deals with estimation of Reliability function and one shape parameter (?) of two- parameters Burr – XII , when ?(shape parameter is known) (?=0.5,1,1.5) and also the initial values of (?=1), while different sample shze n= 10, 20, 30, 50) bare used. The results depend on empirical study through simulation experiments are applied to compare the four methods of estimation, as well as computing the reliability function . The results of Mean square error indicates that Jacknif estimator is better than other three estimators , for all sample size and parameter values

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
International Journal Of Hydrogen Energy
Improvement of bioenergy generation using innovative application of food waste materials for coating carbon nanotubes-loaded bioanode in 3D-microbial fuel cells
...Show More Authors

View Publication
Crossref (9)
Crossref
Publication Date
Wed Feb 15 2023
Journal Name
Environmental Technology
Bio-synthesis of TiO<sub>2</sub> using grape leaves extract and its application for photocatalytic degradation of ibuprofen from aqueous solution
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Electrocautery versus cold steel tonsillectomy comparison study
...Show More Authors

Objective: the objective of this study was to compare the intraoperative blood loss, intraoperative time, postoperative pain and secondary hemorrhage between electrodissection and cold steel dissection tonsillectomy.

Methods: One hundred and six patients were enrolled in this study, the patients were randomly allocated into electrodissection group A (n=51) and cold steel dissection tonsillectomy group B (n=53). All patients are above 7 years and had history of recurrent tonsillitis and/or tonsillar hypertrophy with obstructive symptoms. Intraoperative parameters and postoperative outcome were assessed.

Results: In group A patients had statically significa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 18 2014
Journal Name
International Journal Of Computer Applications
3-Level Techniques Comparison based Image Recognition
...Show More Authors

Image recognition is one of the most important applications of information processing, in this paper; a comparison between 3-level techniques based image recognition has been achieved, using discrete wavelet (DWT) and stationary wavelet transforms (SWT), stationary-stationary-stationary (sss), stationary-stationary-wavelet (ssw), stationary-wavelet-stationary (sws), stationary-wavelet-wavelet (sww), wavelet-stationary- stationary (wss), wavelet-stationary-wavelet (wsw), wavelet-wavelet-stationary (wws) and wavelet-wavelet-wavelet (www). A comparison between these techniques has been implemented. according to the peak signal to noise ratio (PSNR), root mean square error (RMSE), compression ratio (CR) and the coding noise e (n) of each third

... Show More
View Publication
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of Patients with Vitiligo by Intradermal Pricking of Vitiligenous Skin Using Sharp and Blunt Needle
...Show More Authors

View Publication
Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Reduction of Noise and Vibration of Spur Gear by Using Asymmetric Teeth Profiles with Tip Relief
...Show More Authors

Reduction of noise and vibration in spur gear experimentally by using asymmetric teeth profiles with tip relief was presented. Both of classical (symmetric) and asymmetric (with and without tip relief) spur gears are used in this work. Gear test rig was constructed to achieve torsional vibration measuring, and two modified cutters are designed and manufactured to achieve tooth profile modifications. First to cut asymmetric gear tooth with pressure angles (14.5o/25 o) without tip relief for loaded and unloaded tooth sides respectively, and second to cut asymmetric gear tooth with pressure angles (14.5o/25 o) for loaded and unloaded tooth sides respectively with tip relief to ach

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Research Octane Number Improvement of Iraqi Gasoline by Adsorption of n-Paraffins Using Zeolite Molecular Sieves
...Show More Authors

This study focused on the improvement of the quality of gasoline and enhancing its octane number by the reduction of n-paraffins using zeolite 5A. This study was made using batch and continuous mode. The parameters which affected the n-paraffin removal efficiency for each mode were studied. Temperature (30 and 40 ˚C) and mixing time up to 120 min for different amounts of zeolite ranging (10-60 g) were investigated in a batch mode. A maximum removal efficiency of 64% was obtained using 60 g of zeolite at 30 ˚C after a mixing time 120 min. The effect of feed flow rate (0.3-0.8 l/hr) and bed height (10-20 cm) were also studied in a continuous mode. The equilibrium isotherm study was made using different amounts of zeolite (2-20 g) and the

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and evaluation of B-cyclodextrin Based Nanosponges of 5- Fluorouracil by Using Ultrasound Assisted Method
...Show More Authors

 

CD-nanosponges were prepared by crosslinking B-CD with diphenylcarbonate (DPC) using ultrasound assisted technique. 5-FU was incorporated with NS by freeze drying, and the phase solubility study, complexation efficiency (CE) entrapment efficiency were performed. Also, the particle morphology was studied using SEM and AFM. The in-vitro release of 5-FU from the prepared nanosponges was carried out in 0.1N HCl.

5-FU nanosponges particle size was in the nano size. The optimum formula showed a particle size of (405.46±30) nm, with a polydispersity index (PDI) (0.328±0.002) and a negative zeta potential (-18.75±1.8). Also the drug entrapment efficiency varied with the CD: DPC molar ratio from 15.6 % to 30%. The SEM an

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (11)
Scopus Crossref
Publication Date
Sun Jun 09 2019
Journal Name
Al-kindy College Medical Journal
The Effectiveness of Calcaneal Drilling for Treatment of Resistance Cases of Plantar Heel Pain
...Show More Authors

Background: Plantar heel pain is a clinical syndrome characterized by pain and tenderness beneath the heel which is typically worse in the morning and improves after the first few steps in the day. It is a common and frequently disabling clinical complaint that may be caused by a broad spectrum of osseous or soft tissue disorders.

Objective: To evaluate the effectiveness of an operation of multiple drilling of calcaneum for resistant plantar heel pain syndrome.

Methods: During the period from November 2012 to August 2016, 17 patients (17heels) were enrolled in a cohort clinical study at the orthopedic unit in AL-Sheikh Zayed and Al-Wassity Hospitals.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Al-kindy College Medical Journal
The Effectiveness of Calcaneal Drilling for Treatment of Resistance Cases of Plantar Heel Pain
...Show More Authors

Background: Plantar heel pain is a clinical syndrome characterized by pain and tenderness beneath the heel which is typically worse in the morning and improves after the first few steps in the day. It is a common and frequently disabling clinical complaint that may be caused by a broad spectrum of osseous or soft tissue disorders. Objective: To evaluate the effectiveness of an operation of multiple drilling of calcaneum for resistant plantar heel pain syndrome. Methods: During the period from November 2012 to August 2016, 17 patients (17heels) were enrolled in a cohort clinical study at the orthopedic unit in AL-Sheikh Zayed and AlWassity Hospitals. Result: Drilling of the calcaneum is a simple procedure achieving 70.6% cure in resistant as

... Show More
Preview PDF