Permanent magnets of different intensities were used to investigate the effect of a magnetic field in the process of preventing deposits of calcium carbonate. The magnets were fixed on the water line from the tap outside. Then heating a sample of this water in flasks and measuring the amount of sediment in a manner weighted differences. These experiments comprise to the change of the velocity of water flow, which amounted to (0.5, 0.75, 1) m/sec through the magnetic fields that are of magnetic strength (2200, 6000, 9250, 11000) Gauss, and conduct measurements, tests and compare them with those obtained from the use of ordinary water.The results showed the effectiveness of magnetic treatment in reducing the rate of deposition of calcium carbonate where up to 60% after treatment, and this percentage is increasing with increasing magnetic field strength where up to 85% when the intensity of the magnetic field 9250 and 11000 Gauss at the velocity of the water flow of 0.75 m/sec. This percentage of reducing was investigated with increasing the velocity of flow of water through a magnetic field. Also the results showed an increase in total dissolved solids (TDS) as well as electrical conductivity and a decrease in the value of surface tension as a result of magnetic treatment.Observation with the photograph pictures of the distillation apparatus oriented in several laboratories, that the amount of sediment formed a thick layer in the device-free magnetic treatment, but it was not dense and in the few quantity in the apparatus treated with magnetic intensity (8000, 9250) Gauss.
Manganese-zinc ferrite MnxZn1-xFe2O4 (MnZnF) powder was prepared using the sol-gel method. The morphological, structural, and magnetic properties of MnZnF powder were studied using X-ray diffraction (XRD), atomic force microscopy (AFM), energy dispersive X-ray (EDX), field emission-scanning electron microscopes (FE-SEM), and vibrating sample magnetometers (VSM). The XRD results showed that the MnxZn1-xFe2O4 that was formed had a trigonal crystalline structure. AFM results showed that the average diameter of Manganese-Zinc Ferrite is 55.35 nm, indicating that the sample has a nanostructure dimension. The EDX spectrum revealed the presence of transition metals (Mn, Fe, Zn, and O) in Mang
... Show MoreThis paper investigated in the numerical simulation model to calculate the Earth magnetic field components at north provinces of Najaf city (Longitude 44.316 o -44.3592o E and Latitude 32.0508o - 32.0256o N). The components of the Earth magnetic field (total intensity (F), horizontal intensity (H), declination (D), inclination (I), the north component(X), the east component(Y), and Down component(Z)) were found by using spherical harmonic world magnetic model (WMM2010). A great deal of anomaly has been discovered in all components of the Earth magnetic field at the selected region (Long. 44.345o-44.335o E, Lat.32.042o-32.032o N) using Kriging method.
... Show MoreBackground: Multiple sclerosis is a chronic heterogeneous demyelinating axonal and inflammatory disease involving the Central Nervous System [CNS] white matter with a possibility of gray matter involvement in which the insulating covers of nerve cells in the brain and spinal cord are damaged. This damage disrupts the ability of parts of the nervous system to communicate, resulting in a wide range of signs and symptoms. Cerebral venous insufficiency theory was raised as a possible etiology for the disease at 2008 by Zamboni an Italian cardiothoracic surgeon. This theory was defeated by Multiple Sclerosis[ MS] researchers and scientists who thought that the disease is an autoimmune rather than vascular.
Obj
... Show MoreThis paper presents designing an adaptive state feedback controller (ASFC) for a magnetic levitation system (MLS), which is an unstable system and has high nonlinearity and represents a challenging control problem. First, a nonadaptive state feedback controller (SFC) is designed by linearization about a selected equilibrium point and designing a SFC by pole-placement method to achieve maximum overshoot of 1.5% and settling time of 1s (5% criterion). When the operating point changes, the designed controller can no longer achieve the design specifications, since it is designed based on a linearization about a different operating point. This gives rise to utilizing the adaptive control scheme to parameterize the state feedback controll
... Show MoreThis study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding
Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive imaging test with excellent overall sensitivity and specificity for demonstrating the level and the presence of a biliary obstruction. MRCP has emerged as an accurate, diagnostic modality for investigating the biliary and pancreatic duct. In some cases, it has been recommended that preoperative MRCP is a good choice for the detection of CBD stones.
The aim of the s
Objective(s): To evaluate and compare between Health Promotion Program for the Prevention of Epidemics at Primary Health Care Centers in Baghdad City.
Methodology: A descriptive study, using the evaluation and comparative approaches, is conducted to evaluate health promotion program for the prevention of epidemics at primary health care centers in baghdad city from October 15th 2019 through March 1st 2020. A purposive, non-probability, sample of (42) health promotion unit officers were recruited from the same number of primary health care centers which were divided into (14) main, (14) sub and (14) family medicine primary health care centers i
... Show MoreObjectives: The study aims to assess the nurses knowledge toward prevention of complications related to valvular replacement surgery and to find out the relationship between nurses knowledge and their demographic and occupational characteristic's Which as (Age, gender, level of education ,years of experience in Surgical Department , and training sessions)
Methodology: A descriptive design (a cross-sectional study ) was carried out from December 2017 to May 2018 in order to assess nurses' knowledge of preventing complications Valvular Replacement Surgery at Surgical Department in Nasiriyah Heart Center on a purposive (non-probability) sample
... Show More