Urine specimen (253 samples) had been collected from urinary tract infections. The study showed that Proteus mirabilis was responsible for (11.85%) of the urinary tract infections. Also, the study had declared that the ratio of isolation of this bacterium from women was (7.51%) and it was higher than the ratio in both men and children which ranged (1.58%) and (2.76%) respectively. Morphological and biochemical studies had been applied to characterize this bacterium as well as other kinds of microorganisms that were isolated from urinary tract infection in this study. The study deals with typing methods such as using biotyping and typing according to Dienes phenomenon beside the succestibility to antibiotics. The results had shown that the second biotype B.T.2, the third type of Dienes phenomenon D.3 and sixth sensitive type S.3 were most familiar in causing urinary tract infections, while the third biotype was recorded as a new biotype in this study. The study was considered as a first local study that deals with Dienes phenomenon and using it in typing of this bacterium.
Candida Berkh. (1923) occurs naturally in the body. But it becomes opportunistic fungi, meaning that it infects humans when there is any weakening of the immune system, such as exposure to chemotherapy, diabetes, or organ transplantation. Most species of Candida grow at a temperature between 20-40 °C and have a pH of 3-8. Human pathogens of Candida species include C. albicans, C. glabrata, C. lusitaniae, C. parapsilosis, C. tropicalis and C. utili. C. albicans has many virulence factors that facilitate injury process. Virulence factors are considered as a measure of pathogenicity, and it is in the form of fungal toxins, enzymes, or cell structures that facilitate infection, as well as pathogen resistance in different conditions. This study
... Show MoreThe goal of the extant revision was to explore the influence of caffeic acid (CA) extracted from Arctium lappa L. on lipid profile and histology of aorta in rats . Analytical study demonstrated a high percentage of both chlorogenic and caffeic acid in the 80 % methanol extract of the aerial parts (leaves and stems) of Arctium lappa L. from the family Asteraceace. Hypolipidemic activity of caffeic acid was studied against cholesterol induced hypercholesterolemia in Wistar albino rats for thirty days. Rats were separated into normal group (A), hypercholesterolemic positive controller group (B). While, the rest three groups (C, D and E) attended as hypercholesterol
... Show MoreAeromonas salmonicida is a fish pathogen and recognized to cause a variety of diseases in humans. There are a few information about A.salmonicida in Iraq and there is no any previous molecular study on it. During the period of December 2017 to May 2018; Sixteen isolates of the A. salmonicida were isolated and identified from 300 common carp (Cyprinus carpio) fishes stomach in aquarium of Erbil city/ Iraq by using manual, automated Vitek 2 compact system, and confirmed by PCR using gene TonB-dependent siderophore (364bp). Antimicrobial susceptibility was determined by disk diffusion method and the results found that all isolates 100% susceptible to imipenem, 100% resistant to nalidixic acid and variable resistan
... Show MoreIn the present work, it had been measured the concentration of radon gas (CRn) for (10) samples of cement used in constructions before and after painting them using enamel paint, purchased from the local markets, to see the extent of its ability to reduce emissions of Rn-222 in the air. These samples were obtained from different sources available in the local markets in Baghdad and other provinces. The measurements were done by the American-made detector (RAD7). The results showed that the highest CRn in the air emitted from cement samples after coating was in the cement sample (Iranian origin) where the concentration was (58.27 Bq/m3) while the lowest CRn was found in building material samples
... Show MoreThe current study included the separation of three alkaloid compounds from Anastatica Hierochuntica and studied the effect of the these compounds on cancerous cells , specifically liver cancer it was found that compound number one is the most influential or inhibiting at 50 percent followed by compound number three when using concentration of 400 μg/mL.
In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show More