Preferred Language
Articles
/
bsj-1318
Measurement of Radon-222 Concentration in Soil Samples of some Sulfuric Spring in Hit City Using CR-39 Detector
...Show More Authors

In this study, concentrations of radon were measured for seventeen samples of soil distributed in three Sulphuric Spring, in addition to other regions as a background in Hit City in AL-Anbar Governorate. The radon concentrations in soil samples measured by using alpha-emitters registration that emits from radon (222Rn) in (CR-39) track detector. The concentrations values were calculated by a comparison with standard samples. The results show that the radon concentrations in first spring varies from (258.253- 347.762 Bq/m3), second spring (230.374-305.209 Bq/m3), third spring (292.002-336.023 Bq/m3) and the average radon concentration in other regions (187.821 Bq/m3). As a conclusion of the study radon concentration in Sulphuric Spring is relatively higher than the background.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Measurement Radon Concentration in Imported and Local Wood Using Solid State Nuclear Track Detectors
...Show More Authors

Abstract: The aim of the present work is to measure radon concentration in wood. Solid state nuclear track detectors of type CR – 39 was used as measurement device. Eight different samples of imported and local wood were collected from markets. Samples were grinded, dried in order to measure radon concentrations in it. Cylindrical diffusion tube was used as detection technique. Results show that the higher concentration was in Iraqi sample 1 which recorded (14.02 ± 0.9) Bq / m3, while the less was in Emirates Sample which recorded (5.35 ± 1.2) Bq / m3. From the present work, all wood samples were with lowest concentrations of radon gas than other building materials.

View Publication Preview PDF
Crossref
Publication Date
Wed Oct 26 2022
Journal Name
Aims Geosciences
Calculation and determination of radioactivity in the old district of Najaf by using the track detector CR-39 and geographical information systems (GIS) methods
...Show More Authors

This research aims to study the radiation concentration distribution of the old District of Najaf (Iraq), where 15 samples were taken from featured sites in the District, which represents archaeological, religious, and heritage sites. Track detector CR-39 was used to calculate the concentration of three different soil weights for each sample site after being exposed for a month. Geographical information systems (GIS) were used to distribute the radioactive concentration on the sites of the samples, where two interpolation methods, namely the inverse distance weight method (IDW) and the triangle irregular network method (NIT), to study the distribution of the radioactivity concentration. The study showed that the western part of the district

... Show More
View Publication Preview PDF
Crossref (1)
Clarivate Crossref
Publication Date
Mon Mar 12 2018
Journal Name
Arabian Journal For Science And Engineering
Estimate Level of Radon Concentration for Drinking Water in Some Regions of Baghdad City
...Show More Authors

View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Exposure and etching time effects on the fission track density in CR-39 detectors using teeth samples
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Measurement the Concentrations of Radon and Thoron and Their Progeny in the Air Samples of Al-Haswaa City in Babylon province
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Sep 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Radon-Distribution Measurements With CR-39, LR-115 And CN-85 DeteCtors
...Show More Authors

The  aim  of this  work  is to determine radon and  its decay  product concentratiQns  indoor   and  outdoor   in  different   areas   in  north   and middle  are·a of Iraq by using nuclear  trak detectors  , CR-39  , CN- 85 andLR-115.                        -

For   CR-39    detectors   ,   the   highest    radon    concentration  was

(64.07Bq/m3)indoor and  (52.4  Bq/m3)

outdoor &n

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
Measurement of the Radon Concentration and Annual Effective Dose in Malva sylvestris (Khabbaz) Plant Used in Traditional Medicine and Food
...Show More Authors

In this study, the radon gas concentration as well as the annual effective dose in leaves of the Malvasylvestris (Khabbaz) plant used in the traditional treatment and as food in Iraq, for this, it is necessary to evaluate the concentrations radon gas, which were measured using solid state nuclear track detectors (SSNTDs) CR-39 technique.  The  concentration and annual effective dose in samples were collected from Baghdad city ranged from minimum to maximum value 15.815 , 0.498 , 54.445 , 1.717  respectively, while the values of  concentration and annual effective dose in a sample collected from Karbala are 15.297 ,0.482 . These values of  concentration and annual effective dose less were compared with th

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Aug 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A comparison Between Two Etchants Used to Etch Surface of CR-39 Nuclear Track Detector
...Show More Authors

    The search included a comparison between two etchands for etch CR-39 nuclear track detector, by the calculation of bulk etch rate (Vb) which is one of the track etching parameters, by two measuring methods (thichness and change mass). The first type, is the solution prepared  from solving NaOH in Ethanol (NaOH/Ethanol) by varied normalities  under temperature(55ËšC)and etching time (30 min) then comparated with the second type the solution prepared from solving NaOH in water (NaOH/Water) by varied normalities with (70ËšC) and etching time (60 min) . All detectors were irradiated with (5.48 Mev) α-Particles from an 241Am source in during (10 min). The results that Vb would increase with the increase of

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 12 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Assessment of Radon Concentrations in the Soil of South Baghdad Suburbs
...Show More Authors

Measurements of radon gas concentrations were carried out for 12 soil samples at 3 sampling depths (surface, 5 cm and 10 cm) collected from (4) locations in south Baghdad suburbs (Bu'aitha) using solid state nuclear track detector CR-39 and sealed can technique. Radon concentrations for surface samples were ranged from 402.2 to 1538.4 Bq.m-3 with an average 994.4 Bq.m-3. Whereas, radon concentration was ranged from 813.1to 2050.4 Bq.m-3 and from 1309.8 to 4626. 1Bq.m-3 with an average values of 1359.8 Bq.m-3 and 2338.3 Bq.m-3 for 5 cm and 10 cm depths respectively. Maximum radon level was found at the location near to the river (site S4) while the minimum radon level was f

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Indoor risk assessment of radon gas in the science college buildings-University of Mustansiriyah using RAD-7 detector
...Show More Authors

In the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the rang

... Show More
View Publication Preview PDF
Crossref (1)
Crossref