Preferred Language
Articles
/
bsj-1287
Determination of bacterial contamination of milk using fluorometry
...Show More Authors

The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups. The data analysis demonstrated that the proposed method can bring progress in identification of milk quality and contamination with rapidness, high sensitivity and low cost diagnostic tool. Laser light at this wavelength that transmitted by optical fiber can be used for milk samples examination in situe and for more precise results.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Optimization of Voltammetric Determination of Dysprosium (III) Using Plackett-Burman and RSM-CCD Experimental Designs
...Show More Authors

This study was aimed to develop an optimized Dy determination method using differential pulse voltammetry (DPV). The Plackett-Burman (PB) experimental design was used to select significant factors that affect the electrical current response, which were further optimized using the response surface method-central composite design (RSM-CCD). The type of electrolyte solution and amplitude modulation were found as two most significant factors, among the nine factors tested, which enhance the current response based on PB design. Further optimization using RSM-CCD shows that the optimum values for the tw

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Feb 10 2025
Journal Name
Aip Conference Proceedings
Development of an HPLC method for the determination of tramadol hydrochloride using ZIC-HILIC columns
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Spectrophotometric determination of micro amount of palladium(II) platinum (II)By using pyrazolone azo resorcinol
...Show More Authors

A sensitive and selective method have been developed for the determination of palladium (II)and platinum (II) . A new reagent and two complexes have been prepared in ethanolic solutions .The method is based on the chelation of metal ions with 4-(4?- pyrazolon azo) resorcinol (APAR) to form intense color soluble products, that are stable and have a maximum absorption at 595 nm and at 463 nm and ?max of 1.11×10 4 and.1.35 ×104 Lmole-1cm-1 for Pd(II) Pt(II) respectively. A linear correlation of (1.4 – 0.2) and (3.2 -0.4 ) ppm for pd(II) pt(II) respectively .The stability constants , relative errors , a relative standard deviations for Pd(II) and Pt(II) were 0.40×105 , 0.4×104 L mol-1 ,0.34 - 0.21% and 2.4 – 0.91% respectively.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Diclofenac sodium Using 2,4-dinitrophenylhydrazine in Pure Form and Pharmaceutical Preparations
...Show More Authors

A simple and sensitive spectrophotometric method is described for the determination of diclofenac sodium (DCL), in pure form and pharmaceutical formulations. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPH) and coupling of the oxidized product with DCL in alkaline medium to give intensively colored chromogen which exhibits maximum absorption (λmax) at 600 nm, and the concentration of DCL was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, modified simplex method (MSM) has been applied in optimization of the variables affecting the color producing reaction. Beer’s law is obeyed in the

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Baghdad Science Journal
Determination of chlorpheniramine maleate in its pharmaceutical preparations using homemade turbidity flow injection analyzer
...Show More Authors

View Publication
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Reservoir Hydraulic Flow Units and Permeability Estimation Using Flow Zone Indicator Method
...Show More Authors

   Reservoir characterization plays a crucial role in comprehending the distribution of formation properties and fluids within heterogeneous reservoirs. This knowledge is instrumental in constructing an accurate three-dimensional model of the reservoir, facilitating predictions regarding porosity, permeability, and fluid flow distribution. Among the various methods employed for reservoir characterization, the hydraulic flow unit stands out as a widely adopted approach. By effectively subdividing the reservoir into distinct zones, each characterized by unique petrophysical and geological properties, hydraulic flow units enable comprehensive reservoir analysis. The concept of the flow unit is closely tied to the flow zone indicator, a cr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Review using continuous flow injection analysis technique in the determination of several drugs
...Show More Authors

Continuous flow injection analysis (CFIA) is one of the simplest, easiest, and multilateral analytical automation methods in moist chemical analysis. This method depends on changing the physical and chemical properties of a part of the specimen spread out from the specimen injected into the carrier stream. The CFIA technique uses automatic analysis of samples with high efficiency. The CFIA PC compatibility also allows specimens to be treated automatically, reagents to be added, and reaction conditions to be closely monitored. The CFIA is one of the automated chemical analysis methods in which a successive specimen sample is to be estimated and injected into a vector stream from a flowing solution that meets the reagent and mixes at a spe

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Azo Coupling Reaction for indirect Spectrophotometric Determination of Furosemide using Resorcinol as a Reagent
...Show More Authors
Abstract<p>A simple and accurate method to determinate furosemide (FUR) based on converting the secondary amine to primary amine with acidic hydrolysis then azotization by nitrous acid and coupled with resorcinol as a coupling agent in aqueous medium at pH 13. The optical characteristic like beers law limit found to be (0.25-2.5) μg.ml<sup>−1</sup>, detection and quantification limits (0.0196) (0.0654) μg.ml<sup>−1</sup>respectivly and Sandel sensitivity was 0.006738 μg.cm<sup>−2</sup>. The least-square method was used to evaluate the regression equation and the correlation coefficient. The resulted azo dye has a maximum absorbance at 430 nm with light oran</p> ... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Aug 07 2019
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of the Cardiac Patients Knowledge toward Using Anticoagulant Medications at Missan Governorate Hospitals
...Show More Authors

Objective- the study aim to determine the cardiac patient knowledge about anticoagulant medications using and its relationship with demographic data(age. gender. level of education. occupational). Methodology- A descriptive study(quasi-experimental)design was carried out to determine cardiac patient knowledge consider to using anticoagulant medications . Starting from(1th Jun 2017 to5th October 2018).To achieve the objectives of the study, a non-probability sample (a purposive sample) consisted of random sample comprised of (30) patients were taken anticoagulant medications ..The measurement of patient knowledge were collected through the use of questionnaire which is related to patient knowledge toward using the anticoagulant medication

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 01 2019
Journal Name
International Journal Of Pharmaceutical Research
Sensitive spectrophoto metric determination of doxycycline in pure and dosage forms using p-bromanil
...Show More Authors

A simple, precise, and sensitive spectrophotometric method has been established for the analysis of doxycycline. The method includes direct charge transfer complexation of doxycycline withp-Bromanil in acetonitrileto form a colored complex. The intensely colored product formed was quantified based on the absorption band at 377 nm under optimum condition. Beer’s law is obeyed in the concentration range of 1–50 μg.mL-1 with molar absorptivity of 1.5725x104 L.mol-1.cm-1, Sandell's sensitivity index (0.0283) μg.cm-2, detection limit of 0.1064 μg.mL-1, quantification limit 0.3224 μg.mL-1 and association constant of the formed complex (0.75x103). The developed method could find application in routine quality control of doxycycline and has

... Show More
Scopus (2)
Scopus